{"version":"1","language":"en","url":"https://wellficent.com/en/category/energy","self":"https://wellficent.com/api/v1/news-collections?path=%2Fen%2Fcategory%2Fenergy","title":"Energy news: oil, gas, power and wells","description":"Oil, natural gas, power, renewables, geothermal, water and drilling developments, reported with primary sources, clear dates and well-industry context.","htmlIndexable":true,"selection":{},"sort":"published-desc","countUnit":"article-cards","total":641,"page":1,"pageSize":12,"next_url":"https://wellficent.com/api/v1/news-collections?path=%2Fen%2Fcategory%2Fenergy%3Fpage%3D2","previous_url":null,"items":[{"requestedLanguage":"en","fallback":false,"record":{"id":"crude-refining-used-oil-rerefining-mass-balance-evidence-guide","canonicalSlug":"crude-refining-used-oil-rerefining-mass-balance-evidence-guide","url":"https://wellficent.com/en/news/crude-refining-used-oil-rerefining-mass-balance-evidence-guide","language":"en","title":"Crude Refining and Used-Oil Re-Refining: Feedstock, Mass Balance and Capacity Evidence","summary":"Distinguish crude processing, used-oil recovery and lubricant blending, then reproduce a hypothetical mass balance without turning it into a real refinery capacity or performance claim.","body":["A refinery name, a lubricant catalogue and a cluster of storage tanks answer different questions. None alone establishes what enters a plant, which transformation occurs there, or how much it can process. Energy intelligence becomes more useful when facility classification, operating status, ownership and capacity each retain their own evidence.","This engineering guide combines primary-source process definitions with an original accounting example. All example rates, water content and density are prescribed assumptions. They describe no named installation, measured production, typical industry yield or validated process design. The accompanying chart represents four assumed mass exits, not a process-flow diagram."],"keyPoints":[],"sections":[{"heading":"Start with feedstock and product, not the facility name","paragraphs":["EIA describes crude refining through separation, conversion and treatment. EPA distinguishes several destinations for used oil, including re-refining into lubricants and processing into fuel oils. These descriptions establish that different feedstocks and product objectives can sit behind similar industrial vocabulary. They do not identify the process at a particular map location.","Ask whether the incoming material is crude, a refinery intermediate, collected used lubricant or purchased base oil. Then distinguish recovering a base stock from blending an already manufactured base stock with additives. A lubricant product list does not demonstrate crude distillation or used-oil re-refining. Likewise, selling fuel does not establish that the seller manufactures it. Preserve an unknown feedstock until a plant-specific document resolves it."]},{"heading":"Read the process evidence at its actual scope","paragraphs":["Appendix B of DOE’s December 2020 report describes used-oil pretreatment, vacuum separation and finishing options, including hydrogenation, solvent extraction and clay treatment. It also distinguishes base-stock production from treatment aimed at fuel products. The report documents possible routes; it is not an equipment inventory for every used-oil business.","A filtration reference therefore cannot establish a complete re-refinery. Nor does a generic hydrotreater description prove that a named site has hydrogen supply, a particular catalyst or an operating reactor. Retain document date, plant address and the exact process wording. Design announcements, commissioned equipment and current operating evidence should remain separate records."]},{"heading":"Set a mass boundary before calculating yield","paragraphs":["For a defined control volume, total mass conservation is dM/dt = Σṁin − Σṁout. M is contained mass and ṁ is mass flow. At assumed steady inventory, accumulation is zero and total incoming mass equals total outgoing mass. Chemical reactions rearrange material; they do not remove the need to account for it.","Choose whether the boundary covers a separation step, a production train or the whole site. Hydrogen, additives, solvents, purchased intermediates and returned material belong among the inputs whenever they cross that boundary. Water, residues, gaseous streams and material sent for treatment belong among the outputs. Internal recycle is not a second external feed. Align the accounting period before comparing totals."]},{"heading":"Reproduce the hypothetical four-stream ledger","paragraphs":["Assume one feed of 1000 kg/h and four grouped exits: base oil 700 kg/h, a secondary hydrocarbon stream 120 kg/h, water 100 kg/h and residue 80 kg/h. Prescribe zero accumulation and no other material crossing the example boundary. The sum is 700 + 120 + 100 + 80 = 1000 kg/h, so the accounting residual is zero.","This is a stipulated ledger, not a simulation showing that any technology achieves these splits. The grouped exits make no claim about phase, contaminant composition, discharge quality or waste classification. The zero residual follows from the chosen numbers; it does not demonstrate a zero-emission plant or prove that an actual meter closes. No hydrogen-consuming process is represented by this simplified example."]},{"heading":"Keep wet-feed and water-free yield denominators distinct","paragraphs":["On the total incoming-feed basis, the assumed base-oil mass yield is Y = 700/1000 × 100 = 70%. Now additionally prescribe that the feed contains 100 kg/h of water and that all of it exits in the water group. The water-free feed is then 1000 − 100 = 900 kg/h, giving Y* = 700/900 × 100 = 77.777…%, rounded to 77.78%.","The numerator did not increase. Only the denominator changed. Water-free does not mean pure hydrocarbon: other nonwater contaminants may remain. Neither percentage is a recovery fraction of chemically identified lubricant molecules. Such a component recovery would require feed and product composition. Report the basis beside the value rather than comparing these two percentages as different plant efficiencies."]},{"heading":"Use an imbalance to investigate the ledger","paragraphs":["In a separate fictional reporting exercise, retain 1000 kg/h incoming but suppose the reported exits total only 950 kg/h. The positive residual is 50 kg/h, or 5% of the reported feed. It is an unresolved accounting difference. Assigning the entire difference to evaporation, leakage or conversion loss would invent a physical explanation.","Check inventory movement, sampling periods, tank transfers, units, meter calibration and missing streams before interpretation. A batch inventory change cannot be compared directly with an hourly rate without a time basis. Retain original readings and corrections separately. A small arithmetic residual also cannot establish accurate individual meters: errors in different streams can offset."]},{"heading":"Separate a mass rate from volume and capacity","paragraphs":["For an additional illustration, prescribe base-oil density 0.88 kg/L at 20°C and take the 700 kg/h base-oil stream at that same reference condition. Q = ṁ/ρ = 700/0.88 = 795.4545… L/h, rounded to 795.45 L/h. This assumed density is not a measured property or a recommended value for a real product.","Without compatible density and temperature references, a reported tonnage cannot establish barrels per day. Even a valid conversion supplies only a rate on its declared basis. Capacity still needs to identify feed versus product, the particular unit or site, rated versus achieved throughput and the operating-time denominator. Storage volume is an inventory limit, not processing capacity. Leave an unsupported conversion unknown."]},{"heading":"Follow a real record while preserving the example boundary","paragraphs":["Alma Petroli’s Operations page describes atmospheric and vacuum fractionation of crude at its Ravenna plant, with bitumen among the products. This is a useful counterexample to classifying solely by the main product: bitumen specialization does not by itself exclude crude processing. The existing Refinery Atlas record osm-way-681248983 retains the corresponding classification evidence and source link.","Use the cited Atlas page and record API to examine that evidence, then follow the related mass-balance and density guides for the calculation methods. No Alma Petroli rate, yield, density or equipment performance was used in this example. The research link establishes an editorial pathway, not a used-oil feed relationship or a physical supply chain."]},{"heading":"Keep quality and environmental claims outside unsupported arithmetic","paragraphs":["DOE’s 2020 review discusses how system boundaries and assumptions affect energy and environmental comparisons. A closed mass ledger alone cannot establish energy savings, carbon intensity or economic advantage. A comparison needs an equivalent product function, material and utility inputs, residue treatment, transport and a stated allocation method.","Likewise, a base-oil yield does not establish viscosity, stability or a finished lubricant approval. Keep laboratory results, product specifications and commercial qualifications separate from throughput. Archive the exact source, access date, units, assumptions and calculation with each derived value. A later verification date updates the evidence review; it does not turn an old report into a current production measurement."]}],"text":"Crude Refining and Used-Oil Re-Refining: Feedstock, Mass Balance and Capacity Evidence\n\nDistinguish crude processing, used-oil recovery and lubricant blending, then reproduce a hypothetical mass balance without turning it into a real refinery capacity or performance claim.\n\nA refinery name, a lubricant catalogue and a cluster of storage tanks answer different questions. None alone establishes what enters a plant, which transformation occurs there, or how much it can process. Energy intelligence becomes more useful when facility classification, operating status, ownership and capacity each retain their own evidence.\n\nThis engineering guide combines primary-source process definitions with an original accounting example. All example rates, water content and density are prescribed assumptions. They describe no named installation, measured production, typical industry yield or validated process design. The accompanying chart represents four assumed mass exits, not a process-flow diagram.\n\nStart with feedstock and product, not the facility name\n\nEIA describes crude refining through separation, conversion and treatment. EPA distinguishes several destinations for used oil, including re-refining into lubricants and processing into fuel oils. These descriptions establish that different feedstocks and product objectives can sit behind similar industrial vocabulary. They do not identify the process at a particular map location.\n\nAsk whether the incoming material is crude, a refinery intermediate, collected used lubricant or purchased base oil. Then distinguish recovering a base stock from blending an already manufactured base stock with additives. A lubricant product list does not demonstrate crude distillation or used-oil re-refining. Likewise, selling fuel does not establish that the seller manufactures it. Preserve an unknown feedstock until a plant-specific document resolves it.\n\nRead the process evidence at its actual scope\n\nAppendix B of DOE’s December 2020 report describes used-oil pretreatment, vacuum separation and finishing options, including hydrogenation, solvent extraction and clay treatment. It also distinguishes base-stock production from treatment aimed at fuel products. The report documents possible routes; it is not an equipment inventory for every used-oil business.\n\nA filtration reference therefore cannot establish a complete re-refinery. Nor does a generic hydrotreater description prove that a named site has hydrogen supply, a particular catalyst or an operating reactor. Retain document date, plant address and the exact process wording. Design announcements, commissioned equipment and current operating evidence should remain separate records.\n\nSet a mass boundary before calculating yield\n\nFor a defined control volume, total mass conservation is dM/dt = Σṁin − Σṁout. M is contained mass and ṁ is mass flow. At assumed steady inventory, accumulation is zero and total incoming mass equals total outgoing mass. Chemical reactions rearrange material; they do not remove the need to account for it.\n\nChoose whether the boundary covers a separation step, a production train or the whole site. Hydrogen, additives, solvents, purchased intermediates and returned material belong among the inputs whenever they cross that boundary. Water, residues, gaseous streams and material sent for treatment belong among the outputs. Internal recycle is not a second external feed. Align the accounting period before comparing totals.\n\nReproduce the hypothetical four-stream ledger\n\nAssume one feed of 1000 kg/h and four grouped exits: base oil 700 kg/h, a secondary hydrocarbon stream 120 kg/h, water 100 kg/h and residue 80 kg/h. Prescribe zero accumulation and no other material crossing the example boundary. The sum is 700 + 120 + 100 + 80 = 1000 kg/h, so the accounting residual is zero.\n\nThis is a stipulated ledger, not a simulation showing that any technology achieves these splits. The grouped exits make no claim about phase, contaminant composition, discharge quality or waste classification. The zero residual follows from the chosen numbers; it does not demonstrate a zero-emission plant or prove that an actual meter closes. No hydrogen-consuming process is represented by this simplified example.\n\nKeep wet-feed and water-free yield denominators distinct\n\nOn the total incoming-feed basis, the assumed base-oil mass yield is Y = 700/1000 × 100 = 70%. Now additionally prescribe that the feed contains 100 kg/h of water and that all of it exits in the water group. The water-free feed is then 1000 − 100 = 900 kg/h, giving Y* = 700/900 × 100 = 77.777…%, rounded to 77.78%.\n\nThe numerator did not increase. Only the denominator changed. Water-free does not mean pure hydrocarbon: other nonwater contaminants may remain. Neither percentage is a recovery fraction of chemically identified lubricant molecules. Such a component recovery would require feed and product composition. Report the basis beside the value rather than comparing these two percentages as different plant efficiencies.\n\nUse an imbalance to investigate the ledger\n\nIn a separate fictional reporting exercise, retain 1000 kg/h incoming but suppose the reported exits total only 950 kg/h. The positive residual is 50 kg/h, or 5% of the reported feed. It is an unresolved accounting difference. Assigning the entire difference to evaporation, leakage or conversion loss would invent a physical explanation.\n\nCheck inventory movement, sampling periods, tank transfers, units, meter calibration and missing streams before interpretation. A batch inventory change cannot be compared directly with an hourly rate without a time basis. Retain original readings and corrections separately. A small arithmetic residual also cannot establish accurate individual meters: errors in different streams can offset.\n\nSeparate a mass rate from volume and capacity\n\nFor an additional illustration, prescribe base-oil density 0.88 kg/L at 20°C and take the 700 kg/h base-oil stream at that same reference condition. Q = ṁ/ρ = 700/0.88 = 795.4545… L/h, rounded to 795.45 L/h. This assumed density is not a measured property or a recommended value for a real product.\n\nWithout compatible density and temperature references, a reported tonnage cannot establish barrels per day. Even a valid conversion supplies only a rate on its declared basis. Capacity still needs to identify feed versus product, the particular unit or site, rated versus achieved throughput and the operating-time denominator. Storage volume is an inventory limit, not processing capacity. Leave an unsupported conversion unknown.\n\nFollow a real record while preserving the example boundary\n\nAlma Petroli’s Operations page describes atmospheric and vacuum fractionation of crude at its Ravenna plant, with bitumen among the products. This is a useful counterexample to classifying solely by the main product: bitumen specialization does not by itself exclude crude processing. The existing Refinery Atlas record osm-way-681248983 retains the corresponding classification evidence and source link.\n\nUse the cited Atlas page and record API to examine that evidence, then follow the related mass-balance and density guides for the calculation methods. No Alma Petroli rate, yield, density or equipment performance was used in this example. The research link establishes an editorial pathway, not a used-oil feed relationship or a physical supply chain.\n\nKeep quality and environmental claims outside unsupported arithmetic\n\nDOE’s 2020 review discusses how system boundaries and assumptions affect energy and environmental comparisons. A closed mass ledger alone cannot establish energy savings, carbon intensity or economic advantage. A comparison needs an equivalent product function, material and utility inputs, residue treatment, transport and a stated allocation method.\n\nLikewise, a base-oil yield does not establish viscosity, stability or a finished lubricant approval. Keep laboratory results, product specifications and commercial qualifications separate from throughput. Archive the exact source, access date, units, assumptions and calculation with each derived value. A later verification date updates the evidence review; it does not turn an old report into a current production measurement.\n\nTechnical and economic analysis\n\nAnalysis as of: 2026-11-15\n\nEvidence cutoff: 2026-11-15\n\nOutlook horizon: Hypothetical steady-inventory accounting example; no forecast\n\nIllustrative sensitivity\n\nAssumed mass exits from a fictional 1000 kg/h feed\n\nPrescribed assumptions, not measurements: 700 + 120 + 100 + 80 = 1000 kg/h. Zero accumulation and no other crossings are imposed. Base-oil yield is 70% of total feed and 77.78% of the assumed 900 kg/h water-free feed. This chart is a mass ledger, not a process diagram or a typical-yield claim.\n\nThese calculations illustrate stated assumptions; they are not observations or a calibrated forecast.\n\nAssumed base oil: 700 kilograms per hour\n\nAssumed secondary hydrocarbon stream: 120 kilograms per hour\n\nAssumed water: 100 kilograms per hour\n\nAssumed residue: 80 kilograms per hour","category":"energy","region":"world","topics":["oil"],"eventDate":"2026-11-15","eventDateBasis":"analysis-as-of","publishedAt":"2026-11-15T20:51:37Z","modifiedAt":"2026-11-15T20:51:37Z","publicationBasis":"first-publication","preparedAt":"2026-11-15T20:50:46Z","sourcePublishedAt":null,"translatedAt":null,"sources":[{"url":"https://www.eia.gov/energyexplained/oil-and-petroleum-products/refining-crude-oil-the-refining-process.php","name":"EIA — Refining crude oil: the refining process","checkedAt":"2026-11-15"},{"url":"https://www.epa.gov/recycle/managing-reusing-and-recycling-used-oil","name":"US EPA — Managing, Reusing, and Recycling Used Oil (page updated 25 June 2026)","checkedAt":"2026-11-15"},{"url":"https://www.energy.gov/sites/default/files/2020/12/f81/Used%20Oil%20Management%20and%20Beneficial%20Reuse%20Options%20to%20Address%20Section%201.%20E....pdf","name":"US DOE — Used Oil Management and Beneficial Reuse Options, December 2020; Appendix B, printed pp. 124–126, and environmental comparison pp. 74–76","checkedAt":"2026-11-15"},{"url":"https://www.almapetroli.com/operations/","name":"Alma Petroli — Operations: Ravenna crude fractionation; primary operator process description","checkedAt":"2026-11-15"},{"url":"https://wellficent.com/en/refineries/osm-way-681248983","name":"Wellficent Refinery Atlas — Alma Petroli osm-way-681248983; internal research pathway, not an independent primary source","checkedAt":"2026-11-15"},{"url":"https://wellficent.com/api/v1/refineries/osm-way-681248983","name":"Wellficent record API — osm-way-681248983; internal provenance inspection, not example input data","checkedAt":"2026-11-15"}],"translations":{"en":"https://wellficent.com/en/news/crude-refining-used-oil-rerefining-mass-balance-evidence-guide","tr":"https://wellficent.com/tr/news/crude-refining-used-oil-rerefining-mass-balance-evidence-guide","ar":"https://wellficent.com/ar/news/crude-refining-used-oil-rerefining-mass-balance-evidence-guide","fr":"https://wellficent.com/fr/news/crude-refining-used-oil-rerefining-mass-balance-evidence-guide","es":"https://wellficent.com/es/news/crude-refining-used-oil-rerefining-mass-balance-evidence-guide","ru":"https://wellficent.com/ru/news/crude-refining-used-oil-rerefining-mass-balance-evidence-guide","pt":"https://wellficent.com/pt/news/crude-refining-used-oil-rerefining-mass-balance-evidence-guide"},"corrections":[],"locations":[],"type":"analysis","analysis":{"asOf":"2026-11-15","kind":"technical-economic","chart":{"kind":"illustrative","note":{"ar":"افتراضات مفروضة لا قياسات: 700 + 120 + 100 + 80 = 1000 kg/h. يفرض تراكم صفري ولا عبور آخر. مردود زيت الأساس 70% من اللقيم الكلي و77.78% من اللقيم المفترض الخالي من الماء البالغ 900 kg/h. الرسم سجل كتلة وليس مخطط عملية أو ادعاء مردود نموذجي.","en":"Prescribed assumptions, not measurements: 700 + 120 + 100 + 80 = 1000 kg/h. Zero accumulation and no other crossings are imposed. Base-oil yield is 70% of total feed and 77.78% of the assumed 900 kg/h water-free feed. This chart is a mass ledger, not a process diagram or a typical-yield claim.","es":"Supuestos prescritos, no mediciones: 700 + 120 + 100 + 80 = 1000 kg/h. Acumulación cero y ningún otro cruce impuestos. Rendimiento de base: 70 % del total y 77,78 % de los 900 kg/h supuestos sin agua. Registro másico, no diagrama de proceso ni rendimiento típico.","fr":"Hypothèses imposées, pas des mesures : 700 + 120 + 100 + 80 = 1000 kg/h. Accumulation nulle et aucune autre traversée imposées. Rendement de base : 70 % de la charge totale et 77,78 % des 900 kg/h supposés sans eau. Bilan massique, pas schéma de procédé ni rendement typique.","pt":"Hipóteses prescritas, não medições: 700 + 120 + 100 + 80 = 1000 kg/h. Acumulação zero e nenhuma outra travessia impostas. Rendimento de base: 70% do total e 77,78% dos 900 kg/h supostos sem água. Balanço de massa, não fluxograma ou rendimento típico.","ru":"Заданные допущения, не измерения: 700 + 120 + 100 + 80 = 1000 kg/h. Заданы нулевое накопление и отсутствие других пересечений. Выход базы — 70% всего сырья и 77,78% условных 900 kg/h без воды. Это массовый учёт, не схема процесса и не типичный выход.","tr":"Ölçüm değil verilmiş varsayımlar: 700 + 120 + 100 + 80 = 1000 kg/h. Birikim sıfır, diğer madde geçişleri yok kabul edilir. Baz yağ verimi toplam beslemede %70, varsayılan 900 kg/h susuz beslemede %77,78’dir. Grafik proses şeması veya tipik verim iddiası değil, kütle hesabıdır."},"rows":[{"label":{"ar":"زيت أساس مفترض","en":"Assumed base oil","es":"Aceite base supuesto","fr":"Huile de base supposée","pt":"Óleo básico suposto","ru":"Условное базовое масло","tr":"Varsayılan baz yağ"},"value":700},{"label":{"ar":"تيار هيدروكربوني ثانوي مفترض","en":"Assumed secondary hydrocarbon stream","es":"Corriente secundaria de hidrocarburos supuesta","fr":"Courant hydrocarboné secondaire supposé","pt":"Corrente secundária de hidrocarbonetos suposta","ru":"Условный вторичный углеводородный поток","tr":"Varsayılan ikincil hidrokarbon akımı"},"value":120},{"label":{"ar":"ماء مفترض","en":"Assumed water","es":"Agua supuesta","fr":"Eau supposée","pt":"Água suposta","ru":"Условная вода","tr":"Varsayılan su"},"value":100},{"label":{"ar":"متبقيات مفترضة","en":"Assumed residue","es":"Residuo supuesto","fr":"Résidu supposé","pt":"Resíduo suposto","ru":"Условный остаток","tr":"Varsayılan kalıntı"},"value":80}],"unit":"kg/h","title":{"ar":"مخارج كتلية مفترضة من لقيم خيالي 1000 kg/h","en":"Assumed mass exits from a fictional 1000 kg/h feed","es":"Salidas másicas supuestas de una alimentación ficticia de 1000 kg/h","fr":"Sorties massiques supposées pour une charge fictive de 1000 kg/h","pt":"Saídas de massa supostas de uma alimentação fictícia de 1000 kg/h","ru":"Условные массовые выходы при вымышленном входе 1000 kg/h","tr":"Kurmaca 1000 kg/h beslemeden varsayılan kütle çıkışları"},"unitLabel":{"ar":"كيلوغرام في الساعة","en":"kilograms per hour","es":"kilogramos por hora","fr":"kilogrammes par heure","pt":"quilogramas por hora","ru":"килограммы в час","tr":"kilogram/saat"}},"horizon":"Hypothetical steady-inventory accounting example; no forecast","horizonLabel":{"ar":"مثال حسابي افتراضي بمخزون ثابت؛ ليس تنبؤاً","en":"Hypothetical steady-inventory accounting example; no forecast","es":"Ejemplo contable hipotético con inventario constante; sin pronóstico","fr":"Exemple comptable fictif à inventaire constant ; aucune prévision","pt":"Exemplo contábil hipotético com inventário constante; sem previsão","ru":"Условный расчёт при постоянном запасе; без прогноза","tr":"Varsayımsal sabit envanter hesabı; tahmin değildir"},"evidenceCutoff":"2026-11-15"},"relatedArticles":[{"canonicalSlug":"refinery-mass-balance-processing-gain-engineering-guide","url":"https://wellficent.com/en/news/refinery-mass-balance-processing-gain-engineering-guide","title":"Refinery Mass Balance and Processing Gain: Why More Volume Does Not Mean More Mass","language":"en"},{"canonicalSlug":"api-gravity-density-mass-volume-engineering-guide","url":"https://wellficent.com/en/news/api-gravity-density-mass-volume-engineering-guide","title":"API Gravity, Density and Mass–Volume Conversion: A Petroleum Engineering Guide","language":"en"}],"image":{"url":"https://wellficent.com/media/8f1e0a8ea6594502fd88d747e770b30372dad95db5ea2cd889447c344f50965a.webp","width":1536,"height":1024,"alt":"Conceptual refinery process area with two distillation towers, supported pipes and a separate heater; no named facility or engineered process design.","credit":"Wellficent / Codex imagegen — AI-generated conceptual illustration; not an authentic project photograph, site survey or process schematic.","licenseUrl":"https://openai.com/policies/terms-of-use/"}}},{"requestedLanguage":"en","fallback":false,"record":{"id":"well-testing-productivity-index-drawdown-ipr-engineering-guide","canonicalSlug":"well-testing-productivity-index-drawdown-ipr-engineering-guide","url":"https://wellficent.com/en/news/well-testing-productivity-index-drawdown-ipr-engineering-guide","language":"en","title":"Well Testing and Productivity Index: Drawdown, Units and an IPR Example","summary":"A reproducible petroleum engineering guide to pressure drawdown, single-phase productivity, test uncertainty and the limits of linking calculations to Well Atlas records.","body":["A production rate becomes useful engineering evidence only when its pressure, fluid, time and measurement basis are known. A large daily rate alone cannot establish reservoir quality, sustainable deliverability or the benefit of a workover. The first task is to identify what was measured and where, before fitting a performance relationship.","This guide separates source definitions, a deliberately hypothetical calculation and a real research pathway. Every number in the worked example is prescribed for teaching. None is a measurement, forecast or operating limit for the linked SODIR wellbore. The illustration is AI-generated conceptual artwork of a fictional surface installation, not a test schematic or project photograph."],"keyPoints":[],"sections":[{"heading":"Define drawdown at a common pressure datum","paragraphs":["SLB defines production-test drawdown as the difference between average reservoir pressure and flowing bottomhole pressure. Write Δp = p̄r − pwf. Both pressures must refer to a compatible reservoir depth and pressure reference; use absolute pressure consistently here. A wellhead pressure cannot simply replace sandface pressure. Wellbore fluid head and flowing friction separate those measurement locations.","Record gauge depth, datum, calibration, timestamp and whether a quoted pressure is measured or calculated. Measured depth follows the borehole, whereas true vertical depth controls a simple hydrostatic head. The linked depth and drilling-pressure guides explain these distinctions. A static drilling-fluid pressure calculation does not supply flowing reservoir pressure or a production-test interpretation."]},{"heading":"State the productivity definition and the phase assumptions","paragraphs":["The productivity index J expresses a compatible production rate per unit drawdown: J = q/Δp. For the present example q means stock-tank oil rate in STB/day, so J has units STB/day/psi. Retain the declared surface reference conditions. Reservoir barrels, total liquid, oil and gas-equivalent rates cannot silently share that numerator.","A constant-J relation q = J(p̄r − pwf) is assumed only over the example pressure range for single-phase liquid inflow, with effectively unchanged fluid properties and test conditions. It is not a universal oil-well law. SLB describes an inflow performance relationship as rate versus flowing bottomhole pressure and explains that fluid composition and phase behaviour affect its shape. Gas evolution or multiphase flow requires an appropriate model and supporting fluid data."]},{"heading":"Reproduce the fictional reference point","paragraphs":["Prescribe p̄r = 4,000 psia, pwf = 3,000 psia and q = 500 STB/day. The drawdown is 1,000 psi, and J = 500/1000 = 0.5 STB/day/psi. For this teaching exercise also assume a bubblepoint of 2,000 psia and single-phase inflow throughout the evaluated pressure range. These are assumptions, not laboratory PVT results.","Hold reservoir pressure and J fixed. At pwf = 3,500, 3,000 and 2,500 psia, the corresponding drawdowns are 500, 1,000 and 1,500 psi. Multiplication by 0.5 gives 250, 500 and 750 STB/day. The accompanying chart and table contain exactly these calculated scenarios. They are not three observed test points or evidence that any real well can reach the largest rate."]},{"heading":"Bound the arithmetic uncertainty honestly","paragraphs":["Now prescribe independent bounds for the reference point: oil rate 500 ± 25 STB/day, reservoir pressure 4,000 ± 50 psia and flowing pressure 3,000 ± 50 psia. The extreme compatible drawdowns are 900 and 1,100 psi. Combining the lowest rate with the largest drawdown gives Jmin = 475/1100 = 0.431818; combining the highest rate with the smallest drawdown gives Jmax = 525/900 = 0.583333 STB/day/psi.","This is a worst-case interval under the stated bounds, not a confidence interval, probability distribution or instrument specification. Correlated pressure errors, changing fluid properties and model error are not quantified. The interval describes arithmetic sensitivity at the reference point; it does not validate the constant-J assumption or quantify future production uncertainty."]},{"heading":"Treat a test as a pressure-and-rate history","paragraphs":["SLB distinguishes drawdown, buildup, injection and interference tests, and describes pressure-transient analysis using pressure, rate and time. A pressure recorded shortly after shut-in is not automatically a representative average reservoir pressure. Interpretation needs the preceding rate history, test duration, gauge location and an assessment of the flow regime.","A practical review should retain the unedited time series, rate changes, shut-in events, separator conditions, water and gas measurements, calibration records and quality flags. Align clocks before combining pressure and flow. Distinguish a stabilized test rate from an initial peak, an allocation estimate and a monthly average. Without those distinctions, dividing two reported numbers may produce a precise-looking index with no defensible physical meaning."]},{"heading":"Do not diagnose skin or select artificial lift from one ratio","paragraphs":["Skin is a dimensionless representation of impaired or enhanced near-well performance relative to a theoretical reference. A lower apparent J can also accompany different reservoir pressure, fluid state, completion conditions or an inconsistent measurement basis. One rate-pressure pair cannot independently determine permeability, skin and reservoir boundaries. Those quantities require a suitable interpretation with additional evidence.","Likewise, an inflow curve alone does not select a pump, choke or safe production rate. The surface operating point also depends on wellbore and facility pressure requirements, fluid behaviour and equipment constraints. This article supplies no tubing-performance model, sand-control criterion, drawdown limit or intervention recommendation. The fictional 750 STB/day scenario is a multiplication result, not a field instruction."]},{"heading":"Follow a real record without borrowing its identity","paragraphs":["The cited Well Atlas entry no-sodir-112 identifies SODIR source record 112, wellbore 16/11-1 S. Its source page and the existing research interface provide an explicit route to retained documents and test summaries. Inspect each test’s own dates, units and depth references. The presence of a test summary or a shared well name does not establish that it contains the complete, compatible inputs needed for this worked example.","No pressure or rate from that well was used to calculate the chart. Its registry identity is not a verified physical join to another catalogue, a producing-field allocation or a refinery supply relationship. Keep missing inputs unknown. Use the related production-data guide when moving from test rates to calendar-period observations; those are different reporting products with different denominators."]},{"heading":"Keep a reproducible evidence package","paragraphs":["A reviewable productivity estimate should travel with its exact source record, fluid and rate basis, common pressure datum, observation period, calculation, assumptions and limitations. Preserve the original values beside any conversion. Store a calculated index separately from measured pressure and rate, and label fitted or forecast output explicitly. A later source review date does not make old measurements newly observed.","The example can be independently reproduced with division, subtraction and multiplication; no fitted reservoir model or accuracy claim is involved. For an actual study, obtain the missing test history and fluid information before interpreting a curve. This preserves a useful connection between educational petroleum engineering and real records without manufacturing reservoir properties or operational certainty."]}],"text":"Well Testing and Productivity Index: Drawdown, Units and an IPR Example\n\nA reproducible petroleum engineering guide to pressure drawdown, single-phase productivity, test uncertainty and the limits of linking calculations to Well Atlas records.\n\nA production rate becomes useful engineering evidence only when its pressure, fluid, time and measurement basis are known. A large daily rate alone cannot establish reservoir quality, sustainable deliverability or the benefit of a workover. The first task is to identify what was measured and where, before fitting a performance relationship.\n\nThis guide separates source definitions, a deliberately hypothetical calculation and a real research pathway. Every number in the worked example is prescribed for teaching. None is a measurement, forecast or operating limit for the linked SODIR wellbore. The illustration is AI-generated conceptual artwork of a fictional surface installation, not a test schematic or project photograph.\n\nDefine drawdown at a common pressure datum\n\nSLB defines production-test drawdown as the difference between average reservoir pressure and flowing bottomhole pressure. Write Δp = p̄r − pwf. Both pressures must refer to a compatible reservoir depth and pressure reference; use absolute pressure consistently here. A wellhead pressure cannot simply replace sandface pressure. Wellbore fluid head and flowing friction separate those measurement locations.\n\nRecord gauge depth, datum, calibration, timestamp and whether a quoted pressure is measured or calculated. Measured depth follows the borehole, whereas true vertical depth controls a simple hydrostatic head. The linked depth and drilling-pressure guides explain these distinctions. A static drilling-fluid pressure calculation does not supply flowing reservoir pressure or a production-test interpretation.\n\nState the productivity definition and the phase assumptions\n\nThe productivity index J expresses a compatible production rate per unit drawdown: J = q/Δp. For the present example q means stock-tank oil rate in STB/day, so J has units STB/day/psi. Retain the declared surface reference conditions. Reservoir barrels, total liquid, oil and gas-equivalent rates cannot silently share that numerator.\n\nA constant-J relation q = J(p̄r − pwf) is assumed only over the example pressure range for single-phase liquid inflow, with effectively unchanged fluid properties and test conditions. It is not a universal oil-well law. SLB describes an inflow performance relationship as rate versus flowing bottomhole pressure and explains that fluid composition and phase behaviour affect its shape. Gas evolution or multiphase flow requires an appropriate model and supporting fluid data.\n\nReproduce the fictional reference point\n\nPrescribe p̄r = 4,000 psia, pwf = 3,000 psia and q = 500 STB/day. The drawdown is 1,000 psi, and J = 500/1000 = 0.5 STB/day/psi. For this teaching exercise also assume a bubblepoint of 2,000 psia and single-phase inflow throughout the evaluated pressure range. These are assumptions, not laboratory PVT results.\n\nHold reservoir pressure and J fixed. At pwf = 3,500, 3,000 and 2,500 psia, the corresponding drawdowns are 500, 1,000 and 1,500 psi. Multiplication by 0.5 gives 250, 500 and 750 STB/day. The accompanying chart and table contain exactly these calculated scenarios. They are not three observed test points or evidence that any real well can reach the largest rate.\n\nBound the arithmetic uncertainty honestly\n\nNow prescribe independent bounds for the reference point: oil rate 500 ± 25 STB/day, reservoir pressure 4,000 ± 50 psia and flowing pressure 3,000 ± 50 psia. The extreme compatible drawdowns are 900 and 1,100 psi. Combining the lowest rate with the largest drawdown gives Jmin = 475/1100 = 0.431818; combining the highest rate with the smallest drawdown gives Jmax = 525/900 = 0.583333 STB/day/psi.\n\nThis is a worst-case interval under the stated bounds, not a confidence interval, probability distribution or instrument specification. Correlated pressure errors, changing fluid properties and model error are not quantified. The interval describes arithmetic sensitivity at the reference point; it does not validate the constant-J assumption or quantify future production uncertainty.\n\nTreat a test as a pressure-and-rate history\n\nSLB distinguishes drawdown, buildup, injection and interference tests, and describes pressure-transient analysis using pressure, rate and time. A pressure recorded shortly after shut-in is not automatically a representative average reservoir pressure. Interpretation needs the preceding rate history, test duration, gauge location and an assessment of the flow regime.\n\nA practical review should retain the unedited time series, rate changes, shut-in events, separator conditions, water and gas measurements, calibration records and quality flags. Align clocks before combining pressure and flow. Distinguish a stabilized test rate from an initial peak, an allocation estimate and a monthly average. Without those distinctions, dividing two reported numbers may produce a precise-looking index with no defensible physical meaning.\n\nDo not diagnose skin or select artificial lift from one ratio\n\nSkin is a dimensionless representation of impaired or enhanced near-well performance relative to a theoretical reference. A lower apparent J can also accompany different reservoir pressure, fluid state, completion conditions or an inconsistent measurement basis. One rate-pressure pair cannot independently determine permeability, skin and reservoir boundaries. Those quantities require a suitable interpretation with additional evidence.\n\nLikewise, an inflow curve alone does not select a pump, choke or safe production rate. The surface operating point also depends on wellbore and facility pressure requirements, fluid behaviour and equipment constraints. This article supplies no tubing-performance model, sand-control criterion, drawdown limit or intervention recommendation. The fictional 750 STB/day scenario is a multiplication result, not a field instruction.\n\nFollow a real record without borrowing its identity\n\nThe cited Well Atlas entry no-sodir-112 identifies SODIR source record 112, wellbore 16/11-1 S. Its source page and the existing research interface provide an explicit route to retained documents and test summaries. Inspect each test’s own dates, units and depth references. The presence of a test summary or a shared well name does not establish that it contains the complete, compatible inputs needed for this worked example.\n\nNo pressure or rate from that well was used to calculate the chart. Its registry identity is not a verified physical join to another catalogue, a producing-field allocation or a refinery supply relationship. Keep missing inputs unknown. Use the related production-data guide when moving from test rates to calendar-period observations; those are different reporting products with different denominators.\n\nKeep a reproducible evidence package\n\nA reviewable productivity estimate should travel with its exact source record, fluid and rate basis, common pressure datum, observation period, calculation, assumptions and limitations. Preserve the original values beside any conversion. Store a calculated index separately from measured pressure and rate, and label fitted or forecast output explicitly. A later source review date does not make old measurements newly observed.\n\nThe example can be independently reproduced with division, subtraction and multiplication; no fitted reservoir model or accuracy claim is involved. For an actual study, obtain the missing test history and fluid information before interpreting a curve. This preserves a useful connection between educational petroleum engineering and real records without manufacturing reservoir properties or operational certainty.\n\nTechnical and economic analysis\n\nAnalysis as of: 2026-11-15\n\nEvidence cutoff: 2026-11-15\n\nOutlook horizon: Hypothetical single-phase inflow; no forecast horizon\n\nIllustrative sensitivity\n\nFictional constant-productivity inflow scenarios\n\nCalculated scenarios, not observations: q = 0.5 × (4000 − pwf). At pwf 3500 / 3000 / 2500 psia, q is 250 / 500 / 750 STB/day. Reservoir pressure, J and bubblepoint 2000 psia are prescribed; no SODIR 112 inputs or safe-rate claim.\n\nThese calculations illustrate stated assumptions; they are not observations or a calibrated forecast.\n\nAssumed flowing pressure: 3500 psia: 250 stock-tank oil barrels per day\n\nAssumed flowing pressure: 3000 psia: 500 stock-tank oil barrels per day\n\nAssumed flowing pressure: 2500 psia: 750 stock-tank oil barrels per day","category":"energy","region":"world","topics":["oil","gas"],"eventDate":"2026-11-15","eventDateBasis":"analysis-as-of","publishedAt":"2026-11-15T15:51:37Z","modifiedAt":"2026-11-15T15:51:37Z","publicationBasis":"first-publication","preparedAt":"2026-11-15T15:50:59Z","sourcePublishedAt":null,"translatedAt":null,"sources":[{"url":"https://glossary.slb.com/terms/p/productivity_index_pi","name":"SLB Energy Glossary — productivity index (PI)","checkedAt":"2026-11-15"},{"url":"https://glossary.slb.com/en/terms/d/drawdown","name":"SLB Energy Glossary — drawdown","checkedAt":"2026-11-15"},{"url":"https://glossary.slb.com/en/terms/i/inflow_performance_relationship","name":"SLB Energy Glossary — inflow performance relationship","checkedAt":"2026-11-15"},{"url":"https://www.slb.com/resource-library/oilfield-review/defining-series/defining-well-testing","name":"SLB — The Defining Series: Well Testing Fundamentals","checkedAt":"2026-11-15"},{"url":"https://glossary.slb.com/en/terms/s/skin","name":"SLB Energy Glossary — skin","checkedAt":"2026-11-15"},{"url":"https://factpages.sodir.no/en/wellbore/pageview/with/welllogs/112","name":"Norwegian Offshore Directorate — wellbore 16/11-1 S, source record 112","licence":"NLOD 2.0 — source-specific terms apply","checkedAt":"2026-11-15","licenseUrl":"https://data.norge.no/nlod/en/2.0","attribution":"Norwegian Offshore Directorate; the fictional calculation is not source measurement data."},{"url":"https://wellficent.com/en/wells/record/no-sodir-112","name":"Wellficent Well Atlas — retained source record no-sodir-112; not example inputs","checkedAt":"2026-11-15"},{"url":"https://wellficent.com/api/v1/research/wells/no-sodir-112","name":"Wellficent research API — source-scoped documents and test summaries for no-sodir-112","checkedAt":"2026-11-15"}],"translations":{"en":"https://wellficent.com/en/news/well-testing-productivity-index-drawdown-ipr-engineering-guide","tr":"https://wellficent.com/tr/news/well-testing-productivity-index-drawdown-ipr-engineering-guide","ar":"https://wellficent.com/ar/news/well-testing-productivity-index-drawdown-ipr-engineering-guide","fr":"https://wellficent.com/fr/news/well-testing-productivity-index-drawdown-ipr-engineering-guide","es":"https://wellficent.com/es/news/well-testing-productivity-index-drawdown-ipr-engineering-guide","ru":"https://wellficent.com/ru/news/well-testing-productivity-index-drawdown-ipr-engineering-guide","pt":"https://wellficent.com/pt/news/well-testing-productivity-index-drawdown-ipr-engineering-guide"},"corrections":[],"locations":[],"type":"analysis","analysis":{"asOf":"2026-11-15","kind":"technical-economic","chart":{"kind":"illustrative","note":{"ar":"سيناريوهات محسوبة لا مشاهدات: q = 0.5 × (4000 − pwf). عند pwf بقيم 3500 / 3000 / 2500 psia تكون q بقيم 250 / 500 / 750 STB/day. ضغط المكمن وJ وضغط الفقاعة 2000 psia مفروضة؛ لا مدخلات من SODIR 112 ولا ادعاء معدل آمن.","en":"Calculated scenarios, not observations: q = 0.5 × (4000 − pwf). At pwf 3500 / 3000 / 2500 psia, q is 250 / 500 / 750 STB/day. Reservoir pressure, J and bubblepoint 2000 psia are prescribed; no SODIR 112 inputs or safe-rate claim.","es":"Escenarios calculados, no observados: q = 0,5 × (4000 − pwf). Para pwf 3500 / 3000 / 2500 psia, q es 250 / 500 / 750 STB/día. Presión del yacimiento, J y presión de burbuja 2000 psia prescritos; sin entradas SODIR 112 ni afirmación de caudal seguro.","fr":"Scénarios calculés, non observés : q = 0,5 × (4000 − pwf). Pour pwf 3500 / 3000 / 2500 psia, q vaut 250 / 500 / 750 STB/jour. Pression du réservoir, J et pression de bulle 2000 psia imposés ; aucune donnée SODIR 112 ni débit sûr revendiqué.","pt":"Cenários calculados, não observações: q = 0,5 × (4000 − pwf). Para pwf 3500 / 3000 / 2500 psia, q é 250 / 500 / 750 STB/dia. Pressão do reservatório, J e pressão de bolha 2000 psia prescritos; sem entradas SODIR 112 nem alegação de vazão segura.","ru":"Расчётные сценарии, не наблюдения: q = 0,5 × (4000 − pwf). При pwf 3500 / 3000 / 2500 psia q равен 250 / 500 / 750 STB/сут. Давление пласта, J и давление насыщения 2000 psia заданы; данных SODIR 112 и утверждения о безопасном дебите нет.","tr":"Gözlem değil, hesaplanmış senaryolar: q = 0,5 × (4000 − pwf). pwf 3500 / 3000 / 2500 psia için q 250 / 500 / 750 STB/gün. Rezervuar basıncı, J ve 2000 psia kabarcık noktası verilmiştir; SODIR 112 girdisi veya güvenli debi iddiası yoktur."},"rows":[{"label":{"ar":"ضغط الجريان المفترض: 3500 psia","en":"Assumed flowing pressure: 3500 psia","es":"Presión fluyente supuesta: 3500 psia","fr":"Pression en écoulement supposée : 3500 psia","pt":"Pressão em fluxo suposta: 3500 psia","ru":"Условное давление при течении: 3500 psia","tr":"Varsayılan akış basıncı: 3500 psia"},"value":250},{"label":{"ar":"ضغط الجريان المفترض: 3000 psia","en":"Assumed flowing pressure: 3000 psia","es":"Presión fluyente supuesta: 3000 psia","fr":"Pression en écoulement supposée : 3000 psia","pt":"Pressão em fluxo suposta: 3000 psia","ru":"Условное давление при течении: 3000 psia","tr":"Varsayılan akış basıncı: 3000 psia"},"value":500},{"label":{"ar":"ضغط الجريان المفترض: 2500 psia","en":"Assumed flowing pressure: 2500 psia","es":"Presión fluyente supuesta: 2500 psia","fr":"Pression en écoulement supposée : 2500 psia","pt":"Pressão em fluxo suposta: 2500 psia","ru":"Условное давление при течении: 2500 psia","tr":"Varsayılan akış basıncı: 2500 psia"},"value":750}],"unit":"STB/day","title":{"ar":"سيناريوهات افتراضية لتدفق بإنتاجية ثابتة","en":"Fictional constant-productivity inflow scenarios","es":"Escenarios ficticios con productividad constante","fr":"Scénarios fictifs à productivité constante","pt":"Cenários fictícios de influxo com produtividade constante","ru":"Условные сценарии притока с постоянной продуктивностью","tr":"Kurmaca sabit üretkenlik giriş senaryoları"},"unitLabel":{"ar":"براميل نفط يومياً عند ظروف خزان التخزين","en":"stock-tank oil barrels per day","es":"barriles de petróleo a condiciones de tanque por día","fr":"barils d’huile aux conditions de bac par jour","pt":"barris de óleo em condições de tanque por dia","ru":"баррели нефти в условиях товарного резервуара в сутки","tr":"günlük stok tankı koşullarındaki petrol varili"}},"horizon":"Hypothetical single-phase inflow; no forecast horizon","horizonLabel":{"ar":"تدفق افتراضي أحادي الطور؛ لا أفق تنبؤ","en":"Hypothetical single-phase inflow; no forecast horizon","es":"Entrada monofásica hipotética; sin horizonte de pronóstico","fr":"Écoulement monophasique fictif ; aucun horizon prévisionnel","pt":"Influxo monofásico hipotético; sem horizonte de previsão","ru":"Условный однофазный приток; прогнозного горизонта нет","tr":"Varsayımsal tek fazlı giriş; tahmin ufku yok"},"evidenceCutoff":"2026-11-15"},"relatedArticles":[{"canonicalSlug":"drilling-hydrostatic-pressure-ecd-engineering-guide","url":"https://wellficent.com/en/news/drilling-hydrostatic-pressure-ecd-engineering-guide","title":"Drilling pressure: hydrostatics, ECD and the mud window","language":"en"},{"canonicalSlug":"well-log-depth-md-tvd-datum-engineering-guide","url":"https://wellficent.com/en/news/well-log-depth-md-tvd-datum-engineering-guide","title":"Well-log depth: MD, TVD and datum explained","language":"en"},{"canonicalSlug":"oil-gas-production-data-rates-boe-decline-engineering-guide","url":"https://wellficent.com/en/news/oil-gas-production-data-rates-boe-decline-engineering-guide","title":"Oil and gas production data: rates, boe, decline and value","language":"en"}],"image":{"url":"https://wellficent.com/media/1f29a2963e8afbca3e806e9d0ce4bbfada6783458136dbecf7d331681595d468.webp","width":1752,"height":897,"alt":"AI-generated conceptual illustration of a fictional wellhead, choke manifold, test separator and receiving tanks; not SODIR 112, a measured test or a validated layout.","credit":"Wellficent — AI-generated conceptual illustration, built-in imagegen, 15 November 2026. Fictional installation, not project photography or engineering evidence. OpenAI terms apply; source-data rights remain separate.","licenseUrl":"https://openai.com/policies/terms-of-use/"}}},{"requestedLanguage":"en","fallback":false,"record":{"id":"refinery-heat-duty-fuel-efficiency-energy-intensity-engineering-guide","canonicalSlug":"refinery-heat-duty-fuel-efficiency-energy-intensity-engineering-guide","url":"https://wellficent.com/en/news/refinery-heat-duty-fuel-efficiency-energy-intensity-engineering-guide","language":"en","title":"Refinery Heat Duty, Fuel Efficiency and Energy Intensity: An Engineering Guide","summary":"Reproduce a heater heat balance, distinguish useful duty from fuel input, and compare energy intensities with explicit assumptions and verified refinery examples.","body":["A refinery's crude-processing rate, a heater's thermal duty and a site's energy intensity describe different quantities. A figure in barrels per day cannot reveal furnace efficiency, while a megawatt rating does not identify how much crude a plant can distil. Useful comparisons start by identifying the equipment, stream, time interval and energy basis behind each number.","This guide combines foundational DOE thermodynamics and process-heating references with dated CONUEE and EPA documents. Its numerical example is entirely hypothetical: no actual refinery's heat capacity, efficiency, fuel use or operating availability is inferred. The chart is calculated from declared inputs. The accompanying conceptual illustration is not an authentic facility photograph or an engineering design."],"keyPoints":[],"sections":[{"heading":"Define the physical boundary","paragraphs":["For one heater, distinguish the process stream receiving heat from the fuel supplying chemical energy. State whether combustion-air preheating and heat recovery are inside the boundary. Pump and fan electricity, imported steam and exported heat need their own treatment; an undefined mixture of these flows is not a reproducible efficiency measure.","A whole-refinery balance has a broader boundary, potentially including refinery fuel gas, purchased energy and utility transfers. Internal streams should not be counted repeatedly as new external inputs. Keep production, intermediate circulation and energy supply separate. An air-permit boundary may group equipment for regulatory purposes without defining the boundary of your thermal calculation."]},{"heading":"Calculate useful heat with consistent units","paragraphs":["For a steady-flow heater with negligible shaft work and kinetic or potential energy changes, useful duty is Q̇ = ṁ(h_out − h_in). For single-phase sensible heating at approximately constant pressure, with constant specific heat, this simplifies to Q̇ = ṁ c_p ΔT. A phase change requires an enthalpy calculation including latent heat; temperature difference alone is insufficient.","Assume a liquid flow of 100,000 kg/h, c_p = 2.2 kJ/(kg·K) and ΔT = 50 K. Assume the stream remains liquid, with no reaction or accumulation. Then Q̇ = 100,000 × 2.2 × 50 = 11,000,000 kJ/h = 11 GJ/h = 3.055556 MW. The specific heat is a prescribed example input, not a measured crude property. One MW equals 3.6 GJ/h; power and accumulated energy are different quantities."]},{"heading":"Separate useful duty from fuel input","paragraphs":["Define η = Q̇_useful/Ḟ_fuel, using the same heating-value convention throughout. All efficiencies here are assumed on one lower-heating-value basis. At η = 0.80, fuel input is 11/0.80 = 13.75 GJ/h, or 3.819444 MW. Useful heat remains 11 GJ/h; the difference is 2.75 GJ/h within this simplified boundary.","That difference is not an independently measured stack loss. A real assessment must distinguish flue-gas, casing and other losses rather than assigning invented percentages. Nor does the calculation establish burner geometry, fuel composition, flame conditions, oxygen concentration or safe control settings. Electrical auxiliaries remain outside this particular fuel-to-process-heat ratio."]},{"heading":"Compare efficiencies at a fixed duty","paragraphs":["Holding useful duty at 11 GJ/h, assumed efficiencies of 70%, 80% and 90% require 15.714286, 13.75 and 12.222222 GJ/h of fuel respectively. The accessible chart shows these calculated rates. Feed flow and temperature rise are held constant; the comparison neither predicts higher production nor supplies measured performance for Salina Cruz or Commerce City.","Moving from 70% to 90% is a 20-percentage-point efficiency increase. Relative fuel reduction is 1 − 0.70/0.90 = 22.222222%, not 20%. Using unrounded values, the difference is 3.492063 GJ/h. If both cases operated for an assumed 8,000 h, the annual difference would be 27,936.507937 GJ. Those hours are an assumption, not plant availability."]},{"heading":"Normalize intensity without changing the denominator","paragraphs":["The example processes 100 t/h. At 80% assumed efficiency, fuel intensity is 13.75/100 = 0.1375 GJ/t of feed; useful-heat intensity is 11/100 = 0.11 GJ/t. These two indicators answer different questions. Neither is a whole-refinery benchmark, a product carbon intensity or a published industry average.","A per-barrel comparison also requires liquid density and a declared volume reference condition. Do not substitute finished-product barrels for crude-feed tonnes or mix calendar-day and stream-day denominators. Startup, shutdown, changes in feed composition and utilization can change site intensity even when individual equipment efficiency is unchanged. Preserve the reporting period and measurement scope."]},{"heading":"Read the Salina Cruz audit on its own terms","paragraphs":["CONUEE's 6 June 2024 report describes a 14–17 May 2024 energy-management follow-up at Salina Cruz, Oaxaca. Auditors visited the primary and vacuum plants, catalytic plant, hydro-reformer and main services. The account discusses operating windows, boiler maintenance and fired-heater burners. It provides firsthand evidence of the named site's refining and energy-management activities.","The audit's installed crude-capacity description is separate from heater duty. Its energy-management maturity finding is not a measured thermal efficiency or proof that a particular retrofit has been commissioned. The directly linked Atlas record preserves unknown current capacity and operating status. None of this guide's hypothetical flow, temperature rise or efficiency is assigned to that refinery."]},{"heading":"Distinguish Commerce City plants from permit boundaries","paragraphs":["EPA's 30 December 2024 order describes Commerce City's Plants 1 and 3 as an integrated petroleum refinery and identifies the separately permitted East Plant 2 within one major air-emission source. The July 2023 East Plant order addresses crude and vacuum heaters. These documents identify process and permit scopes; separate permits do not create additive crude-processing capacities.","An emission limit or fuel-based emissions calculation is not a measurement of heat delivered to the process. The Atlas record therefore keeps capacity and current operating state unknown despite corroborated refinery identity. The research link does not create an EIA capacity join, certify permit compliance or establish a physical supply chain to a well."]},{"heading":"Build a reproducible measurement package","paragraphs":["A site calculation needs synchronized process-flow, inlet/outlet temperature and pressure measurements, an appropriate enthalpy or property model, fuel-flow measurements and fuel heating value. Record calibration, sampling intervals, instrument uncertainty and whether values are gross or net. Missing fuel composition, density or heat-capacity data should remain unknown rather than being filled with convenient defaults.","For vaporizing or reacting streams, include the relevant phase and reaction enthalpies. For transient operation, retain accumulation and the actual integration period. Compare calculated duty against an independently measured energy balance where possible. The present steady-state example demonstrates arithmetic only; it is not a validated simulator or a trained predictive model."]},{"heading":"Evaluate improvement opportunities within operating limits","paragraphs":["DOE's process-heating sourcebook examines heat recovery, air leakage, heat-transfer surfaces and combustion losses as parts of a system. A change to one component can affect draft, pressure drop, fouling, reliability and other energy demands. A screening ratio cannot establish a safe burner adjustment or replace equipment-specific engineering and operating procedures.","Economic evaluation also needs verified tariffs, capital cost, maintenance consequences and a defensible operating schedule. The hypothetical annual energy difference is not a project saving or payback forecast. Read it alongside the capacity, density, mass-balance and permit-status guides, keeping observed site evidence separate from assumed engineering inputs."]}],"text":"Refinery Heat Duty, Fuel Efficiency and Energy Intensity: An Engineering Guide\n\nReproduce a heater heat balance, distinguish useful duty from fuel input, and compare energy intensities with explicit assumptions and verified refinery examples.\n\nA refinery's crude-processing rate, a heater's thermal duty and a site's energy intensity describe different quantities. A figure in barrels per day cannot reveal furnace efficiency, while a megawatt rating does not identify how much crude a plant can distil. Useful comparisons start by identifying the equipment, stream, time interval and energy basis behind each number.\n\nThis guide combines foundational DOE thermodynamics and process-heating references with dated CONUEE and EPA documents. Its numerical example is entirely hypothetical: no actual refinery's heat capacity, efficiency, fuel use or operating availability is inferred. The chart is calculated from declared inputs. The accompanying conceptual illustration is not an authentic facility photograph or an engineering design.\n\nDefine the physical boundary\n\nFor one heater, distinguish the process stream receiving heat from the fuel supplying chemical energy. State whether combustion-air preheating and heat recovery are inside the boundary. Pump and fan electricity, imported steam and exported heat need their own treatment; an undefined mixture of these flows is not a reproducible efficiency measure.\n\nA whole-refinery balance has a broader boundary, potentially including refinery fuel gas, purchased energy and utility transfers. Internal streams should not be counted repeatedly as new external inputs. Keep production, intermediate circulation and energy supply separate. An air-permit boundary may group equipment for regulatory purposes without defining the boundary of your thermal calculation.\n\nCalculate useful heat with consistent units\n\nFor a steady-flow heater with negligible shaft work and kinetic or potential energy changes, useful duty is Q̇ = ṁ(h_out − h_in). For single-phase sensible heating at approximately constant pressure, with constant specific heat, this simplifies to Q̇ = ṁ c_p ΔT. A phase change requires an enthalpy calculation including latent heat; temperature difference alone is insufficient.\n\nAssume a liquid flow of 100,000 kg/h, c_p = 2.2 kJ/(kg·K) and ΔT = 50 K. Assume the stream remains liquid, with no reaction or accumulation. Then Q̇ = 100,000 × 2.2 × 50 = 11,000,000 kJ/h = 11 GJ/h = 3.055556 MW. The specific heat is a prescribed example input, not a measured crude property. One MW equals 3.6 GJ/h; power and accumulated energy are different quantities.\n\nSeparate useful duty from fuel input\n\nDefine η = Q̇_useful/Ḟ_fuel, using the same heating-value convention throughout. All efficiencies here are assumed on one lower-heating-value basis. At η = 0.80, fuel input is 11/0.80 = 13.75 GJ/h, or 3.819444 MW. Useful heat remains 11 GJ/h; the difference is 2.75 GJ/h within this simplified boundary.\n\nThat difference is not an independently measured stack loss. A real assessment must distinguish flue-gas, casing and other losses rather than assigning invented percentages. Nor does the calculation establish burner geometry, fuel composition, flame conditions, oxygen concentration or safe control settings. Electrical auxiliaries remain outside this particular fuel-to-process-heat ratio.\n\nCompare efficiencies at a fixed duty\n\nHolding useful duty at 11 GJ/h, assumed efficiencies of 70%, 80% and 90% require 15.714286, 13.75 and 12.222222 GJ/h of fuel respectively. The accessible chart shows these calculated rates. Feed flow and temperature rise are held constant; the comparison neither predicts higher production nor supplies measured performance for Salina Cruz or Commerce City.\n\nMoving from 70% to 90% is a 20-percentage-point efficiency increase. Relative fuel reduction is 1 − 0.70/0.90 = 22.222222%, not 20%. Using unrounded values, the difference is 3.492063 GJ/h. If both cases operated for an assumed 8,000 h, the annual difference would be 27,936.507937 GJ. Those hours are an assumption, not plant availability.\n\nNormalize intensity without changing the denominator\n\nThe example processes 100 t/h. At 80% assumed efficiency, fuel intensity is 13.75/100 = 0.1375 GJ/t of feed; useful-heat intensity is 11/100 = 0.11 GJ/t. These two indicators answer different questions. Neither is a whole-refinery benchmark, a product carbon intensity or a published industry average.\n\nA per-barrel comparison also requires liquid density and a declared volume reference condition. Do not substitute finished-product barrels for crude-feed tonnes or mix calendar-day and stream-day denominators. Startup, shutdown, changes in feed composition and utilization can change site intensity even when individual equipment efficiency is unchanged. Preserve the reporting period and measurement scope.\n\nRead the Salina Cruz audit on its own terms\n\nCONUEE's 6 June 2024 report describes a 14–17 May 2024 energy-management follow-up at Salina Cruz, Oaxaca. Auditors visited the primary and vacuum plants, catalytic plant, hydro-reformer and main services. The account discusses operating windows, boiler maintenance and fired-heater burners. It provides firsthand evidence of the named site's refining and energy-management activities.\n\nThe audit's installed crude-capacity description is separate from heater duty. Its energy-management maturity finding is not a measured thermal efficiency or proof that a particular retrofit has been commissioned. The directly linked Atlas record preserves unknown current capacity and operating status. None of this guide's hypothetical flow, temperature rise or efficiency is assigned to that refinery.\n\nDistinguish Commerce City plants from permit boundaries\n\nEPA's 30 December 2024 order describes Commerce City's Plants 1 and 3 as an integrated petroleum refinery and identifies the separately permitted East Plant 2 within one major air-emission source. The July 2023 East Plant order addresses crude and vacuum heaters. These documents identify process and permit scopes; separate permits do not create additive crude-processing capacities.\n\nAn emission limit or fuel-based emissions calculation is not a measurement of heat delivered to the process. The Atlas record therefore keeps capacity and current operating state unknown despite corroborated refinery identity. The research link does not create an EIA capacity join, certify permit compliance or establish a physical supply chain to a well.\n\nBuild a reproducible measurement package\n\nA site calculation needs synchronized process-flow, inlet/outlet temperature and pressure measurements, an appropriate enthalpy or property model, fuel-flow measurements and fuel heating value. Record calibration, sampling intervals, instrument uncertainty and whether values are gross or net. Missing fuel composition, density or heat-capacity data should remain unknown rather than being filled with convenient defaults.\n\nFor vaporizing or reacting streams, include the relevant phase and reaction enthalpies. For transient operation, retain accumulation and the actual integration period. Compare calculated duty against an independently measured energy balance where possible. The present steady-state example demonstrates arithmetic only; it is not a validated simulator or a trained predictive model.\n\nEvaluate improvement opportunities within operating limits\n\nDOE's process-heating sourcebook examines heat recovery, air leakage, heat-transfer surfaces and combustion losses as parts of a system. A change to one component can affect draft, pressure drop, fouling, reliability and other energy demands. A screening ratio cannot establish a safe burner adjustment or replace equipment-specific engineering and operating procedures.\n\nEconomic evaluation also needs verified tariffs, capital cost, maintenance consequences and a defensible operating schedule. The hypothetical annual energy difference is not a project saving or payback forecast. Read it alongside the capacity, density, mass-balance and permit-status guides, keeping observed site evidence separate from assumed engineering inputs.\n\nTechnical and economic analysis\n\nAnalysis as of: 2026-11-11\n\nEvidence cutoff: 2026-11-11\n\nOutlook horizon: Hypothetical steady-state heater comparison\n\nIllustrative sensitivity\n\nHypothetical fuel input at a fixed useful duty of 11 GJ/h\n\nCalculated examples: fuel input = 11/η, with assumed efficiencies 70%, 80% and 90% on the same lower-heating-value basis. Fixed 100,000 kg/h liquid feed, c_p 2.2 kJ/(kg·K), ΔT 50 K; no phase change, reaction or accumulation. Not measured site performance or a forecast.\n\nThese calculations illustrate stated assumptions; they are not observations or a calibrated forecast.\n\n70% assumed efficiency: 15.7143 gigajoules per hour\n\n80% assumed efficiency: 13.75 gigajoules per hour\n\n90% assumed efficiency: 12.2222 gigajoules per hour","category":"energy","region":"world","topics":["oil","gas"],"eventDate":"2026-11-11","eventDateBasis":"analysis-as-of-date","publishedAt":"2026-11-11T15:37:55Z","modifiedAt":"2026-11-11T15:43:58Z","publicationBasis":"first-publication","preparedAt":"2026-11-11T15:32:47Z","sourcePublishedAt":null,"translatedAt":null,"sources":[{"url":"https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL1.pdf","name":"DOE Fundamentals Handbook — Thermodynamics, archived training reference","checkedAt":"2026-11-11"},{"url":"https://www.energy.gov/sites/prod/files/2014/05/f15/process_heating_sourcebook2.pdf","name":"DOE — Improving Process Heating System Performance, second edition, 2007","checkedAt":"2026-11-11"},{"url":"https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication811e2008.pdf","name":"NIST SP 811 — SI units and conversions, 2008 edition","checkedAt":"2026-11-11"},{"url":"https://www.gob.mx/conuee/articulos/se-realiza-auditoria-al-proceso-de-implementacion-del-sistema-de-gestion-de-la-energia","name":"CONUEE — Salina Cruz energy-management site audit, 6 June 2024","checkedAt":"2026-11-11"},{"url":"https://www.epa.gov/system/files/documents/2025-01/suncor-plants-1-and-3-order-ii-12-30-2024_0.pdf","name":"EPA — Commerce City Plants 1 and 3 order, 30 December 2024","checkedAt":"2026-11-11"},{"url":"https://www.epa.gov/system/files/documents/2023-08/Suncor%20Plant%202%20Order_07-31-23.pdf","name":"EPA — Commerce City East Plant order, 31 July 2023","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-113738260","name":"Wellficent Atlas — Salina Cruz source record","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-134992178","name":"Wellficent Atlas — Commerce City source record","checkedAt":"2026-11-11"}],"translations":{"en":"https://wellficent.com/en/news/refinery-heat-duty-fuel-efficiency-energy-intensity-engineering-guide","tr":"https://wellficent.com/tr/news/refinery-heat-duty-fuel-efficiency-energy-intensity-engineering-guide","ar":"https://wellficent.com/ar/news/refinery-heat-duty-fuel-efficiency-energy-intensity-engineering-guide","fr":"https://wellficent.com/fr/news/refinery-heat-duty-fuel-efficiency-energy-intensity-engineering-guide","es":"https://wellficent.com/es/news/refinery-heat-duty-fuel-efficiency-energy-intensity-engineering-guide","ru":"https://wellficent.com/ru/news/refinery-heat-duty-fuel-efficiency-energy-intensity-engineering-guide","pt":"https://wellficent.com/pt/news/refinery-heat-duty-fuel-efficiency-energy-intensity-engineering-guide"},"corrections":[{"at":"2026-11-11T15:43:58Z","language":"en","text":"Keep every formula, value, source and first publication unchanged; add paired text-direction isolates to Arabic scientific expressions so formulas and units read coherently from left to right on mobile. Other editions and the generated illustration are unchanged."}],"locations":[],"type":"analysis","analysis":{"asOf":"2026-11-11","kind":"technical-economic","chart":{"kind":"illustrative","note":{"ar":"أمثلة محسوبة: مدخل الوقود = ⁦11/η⁩، بكفاءات مفترضة ⁦70%⁩ و⁦80%⁩ و⁦90%⁩ على أساس واحد للقيمة الحرارية الدنيا. تغذية سائلة ثابتة ⁦100,000 kg/h⁩ و⁦c_p⁩ قدرها ⁦2.2 kJ/(kg·K)⁩ و⁦ΔT⁩ قدرها ⁦50 K⁩؛ دون تغير طور أو تفاعل أو تراكم. ليست أداء موقع مقاساً أو توقعاً.","en":"Calculated examples: fuel input = 11/η, with assumed efficiencies 70%, 80% and 90% on the same lower-heating-value basis. Fixed 100,000 kg/h liquid feed, c_p 2.2 kJ/(kg·K), ΔT 50 K; no phase change, reaction or accumulation. Not measured site performance or a forecast.","es":"Ejemplos calculados: entrada = 11/η, con eficiencias supuestas del 70%, 80% y 90% sobre la misma base de poder calorífico inferior. Alimentación líquida fija de 100.000 kg/h, c_p 2,2 kJ/(kg·K), ΔT 50 K; sin cambio de fase, reacción ni acumulación. No es desempeño medido ni pronóstico.","fr":"Exemples calculés : apport = 11/η, pour des rendements supposés de 70 %, 80 % et 90 % sur la même base de pouvoir calorifique inférieur. Charge liquide fixe de 100 000 kg/h, c_p 2,2 kJ/(kg·K), ΔT 50 K ; ni changement de phase, réaction ou accumulation. Ni performance de site mesurée, ni prévision.","pt":"Exemplos calculados: entrada = 11/η, com eficiências admitidas de 70%, 80% e 90% na mesma base de poder calorífico inferior. Alimentação líquida fixa de 100.000 kg/h, c_p 2,2 kJ/(kg·K), ΔT 50 K; sem mudança de fase, reação ou acumulação. Não é desempenho medido nem previsão.","ru":"Расчётные примеры: энергия топлива = 11/η, условные КПД 70%, 80% и 90% на одной основе низшей теплоты сгорания. Постоянное жидкое сырьё 100 000 kg/h, c_p 2,2 kJ/(kg·K), ΔT 50 K; без фазового перехода, реакции и накопления. Не измеренные показатели площадки и не прогноз.","tr":"Hesaplanmış örnekler: yakıt girişi = 11/η; aynı alt ısıl değer temelinde varsayılan %70, %80 ve %90 verim. Sabit 100.000 kg/h sıvı besleme, c_p 2,2 kJ/(kg·K), ΔT 50 K; faz değişimi, reaksiyon veya birikim yoktur. Ölçülmüş tesis performansı veya öngörü değildir."},"rows":[{"label":{"ar":"كفاءة مفترضة ⁦70%⁩","en":"70% assumed efficiency","es":"Eficiencia supuesta del 70%","fr":"Rendement supposé de 70 %","pt":"Eficiência admitida de 70%","ru":"Условный КПД 70%","tr":"Varsayılan %70 verim"},"value":15.714286},{"label":{"ar":"كفاءة مفترضة ⁦80%⁩","en":"80% assumed efficiency","es":"Eficiencia supuesta del 80%","fr":"Rendement supposé de 80 %","pt":"Eficiência admitida de 80%","ru":"Условный КПД 80%","tr":"Varsayılan %80 verim"},"value":13.75},{"label":{"ar":"كفاءة مفترضة ⁦90%⁩","en":"90% assumed efficiency","es":"Eficiencia supuesta del 90%","fr":"Rendement supposé de 90 %","pt":"Eficiência admitida de 90%","ru":"Условный КПД 90%","tr":"Varsayılan %90 verim"},"value":12.222222}],"unit":"GJ/h","title":{"ar":"مدخل وقود افتراضي عند حمل مفيد ثابت قدره ⁦11 GJ/h⁩","en":"Hypothetical fuel input at a fixed useful duty of 11 GJ/h","es":"Entrada hipotética de combustible con carga útil fija de 11 GJ/h","fr":"Apport fictif de combustible pour une puissance utile fixe de 11 GJ/h","pt":"Entrada hipotética de combustível com carga útil fixa de 11 GJ/h","ru":"Условная энергия топлива при постоянной полезной нагрузке 11 GJ/h","tr":"11 GJ/h sabit yararlı yükte varsayımsal yakıt girişi"},"unitLabel":{"ar":"غيغاجول في الساعة","en":"gigajoules per hour","es":"gigajulios por hora","fr":"gigajoules par heure","pt":"gigajoules por hora","ru":"гигаджоули в час","tr":"saatte gigajul"}},"horizon":"Hypothetical steady-state heater comparison","horizonLabel":{"ar":"مقارنة افتراضية لسخان في حالة مستقرة","en":"Hypothetical steady-state heater comparison","es":"Comparación hipotética de calentadores en régimen estacionario","fr":"Comparaison fictive de réchauffeurs en régime permanent","pt":"Comparação hipotética de aquecedores em regime estacionário","ru":"Условное сравнение нагревателей в стационарном режиме","tr":"Varsayımsal kararlı durum ısıtıcı karşılaştırması"},"evidenceCutoff":"2026-11-11"},"relatedArticles":[{"canonicalSlug":"refinery-capacity-calendar-stream-day-engineering-guide","url":"https://wellficent.com/en/news/refinery-capacity-calendar-stream-day-engineering-guide","title":"Refinery capacity: calendar day, stream day and actual throughput","language":"en"},{"canonicalSlug":"api-gravity-density-mass-volume-engineering-guide","url":"https://wellficent.com/en/news/api-gravity-density-mass-volume-engineering-guide","title":"API Gravity, Density and Mass–Volume Conversion: A Petroleum Engineering Guide","language":"en"},{"canonicalSlug":"refinery-mass-balance-processing-gain-engineering-guide","url":"https://wellficent.com/en/news/refinery-mass-balance-processing-gain-engineering-guide","title":"Refinery Mass Balance and Processing Gain: Why More Volume Does Not Mean More Mass","language":"en"},{"canonicalSlug":"refinery-terminal-status-permit-data-engineering-guide","url":"https://wellficent.com/en/news/refinery-terminal-status-permit-data-engineering-guide","title":"Refinery or Fuel Terminal? How to Read Plant Status, Permits and Engineering Data","language":"en"}],"image":{"url":"https://wellficent.com/media/47f5ee3ec462e5e20fdfb56e574c7583046b27f53372bb7de03d49e93cc6c546.webp","width":1536,"height":1024,"alt":"Conceptual refinery process heater with an exhaust stack, supported piping and a horizontal heat exchanger; no real facility or rated duty is represented.","credit":"Wellficent / OpenAI — AI-generated conceptual illustration; not an authentic project photograph, process schematic or engineering evidence.","licenseUrl":"https://openai.com/policies/terms-of-use/"}}},{"requestedLanguage":"en","fallback":false,"record":{"id":"refinery-mass-balance-processing-gain-engineering-guide","canonicalSlug":"refinery-mass-balance-processing-gain-engineering-guide","url":"https://wellficent.com/en/news/refinery-mass-balance-processing-gain-engineering-guide","language":"en","title":"Refinery Mass Balance and Processing Gain: Why More Volume Does Not Mean More Mass","summary":"A reproducible liquid-density example explains refinery processing gain, mass conservation, yield definitions and the boundary between crude intake and secondary-unit throughput.","body":["Refining can produce a larger liquid volume than the volume of crude supplied. That observation does not, by itself, establish extra mass, high energy efficiency or spare crude-processing capacity. Volume depends on density and reporting conditions, while a material balance must account for every relevant input, output and change in inventory.","This guide combines EIA definitions with a deliberately simplified, hypothetical batch calculation. All supplied densities refer to stable liquids at the same assumed 15 °C and 101.325 kPa. They are prescribed example inputs, not measured assays or density corrections derived from API gravity. The chart is calculated from those inputs; the editorial illustration depicts no real facility or engineering design."],"keyPoints":[],"sections":[{"heading":"Choose the boundary and the reporting period","paragraphs":["First decide whether the balance covers a distillation unit, a conversion unit, a tank system or the entire refinery. Identify the calendar interval and the inventory included at its start and end. Crude delivered to a terminal need not equal crude charged to a process during that interval: some may enter or leave storage. Products manufactured need not equal products dispatched. A comparison of two annual totals therefore needs their definitions, not merely matching years. Keep the mass basis, volume reference conditions and time denominator alongside the values. A figure in tonnes is not interchangeable with barrels, and a batch volume has no daily-rate meaning until a time basis is supplied."]},{"heading":"Write the material balance before calculating yield","paragraphs":["For a defined period, the total mass equation is ΔM = Σm_in − Σm_out, where ΔM is the increase in inventory inside the boundary. At steady inventory, inputs and outputs balance. In a real refinery, the chosen boundary may require imported hydrogen, other feedstocks, water or steam, gas products, recovered sulfur, wastewater, fuel consumed and losses to be accounted for. Streams excluded from a hydrocarbon-only reporting convention must be identified. Chemical reactions rearrange material; they do not remove the need to balance mass. Heat duty, power and economic margin are separate balances. A high volumetric yield alone cannot establish thermal efficiency or profitability. If combustion equipment is inside the total-mass boundary, combustion air and flue gas must also be included."]},{"heading":"Specify the hypothetical batch","paragraphs":["Assume 100,000 kg of feed with density 850 kg/m³. The output is prescribed as three separate liquid parcels: 45,000 kg at 740 kg/m³, 40,000 kg at 840 kg/m³ and 15,000 kg at 980 kg/m³. Call them light, middle and heavy liquids rather than assigning measured commercial product specifications. Their masses add exactly to 100,000 kg. The example deliberately excludes gas, water, sulfur products, fuel consumption, losses, additional feeds and inventory accumulation. It is a density-arithmetic exercise, not a refinery simulation, an achievable yield slate or a prediction for any mapped plant. Actual process design would need composition, reaction chemistry, phase behaviour and an energy balance."]},{"heading":"Calculate each liquid volume reproducibly","paragraphs":["Use V = m/ρ, with mass in kilograms and density in kg/m³, so the result is in cubic metres. The feed volume is 100000/850 = 117.647059 m³ after rounding. The light parcel occupies 45000/740 = 60.810811 m³; the middle parcel occupies 40000/840 = 47.619048 m³; and the heavy parcel occupies 15000/980 = 15.306122 m³. Retaining unrounded intermediate values gives a total product volume of 123.735981 m³. The accompanying chart compares this total with the feed volume on the same reference basis. It does not add a total row to its own components, compare gas standard volume with liquid volume or imply a daily throughput."]},{"heading":"Separate volumetric increase from mass residual","paragraphs":["The calculated volume difference is 6.088922 m³. The relative increase is (V_out/V_in − 1) × 100 = 5.175584%, or 5.18% after rounding. The mass residual remains 100000 − (45000 + 40000 + 15000) = 0 kg. The larger sum of separate product volumes follows from the supplied mass distribution and densities. It is not extra material. These parcels have not been mixed together, so no volume-additive blending law is being assumed. EIA’s January 2024 refining-model description explains processing gain through conversion of heavy feeds to lower-density products. Our arithmetic illustrates the density principle; it does not reproduce an observed EIA gain series or model the chemistry that creates a real product slate."]},{"heading":"Read the yield definition used by the dataset","paragraphs":["A mass fraction, a liquid-volume fraction and an official refinery-yield statistic are different quantities. EIA’s current glossary defines its denominator using crude oil, hydrogen, other hydrocarbons and net unfinished-oil inputs, and specifies adjustments for finished motor gasoline, aviation gasoline and distillate fuel oil. It also explains a methodological change for data before January 2009. Consequently, the example’s 45% light-liquid mass share is not an EIA gasoline yield. For comparisons across reports or years, retain product scope, denominator, net-versus-gross treatment, stock changes and method version. Do not silently harmonise a published statistic by substituting a convenient denominator."]},{"heading":"Do not add serial unit capacities","paragraphs":["Suppose a hypothetical primary unit accepts 100,000 bbl/day and a vacuum unit treating its residue has a 50,000 bbl/day rating. Their sum does not establish 150,000 bbl/day of fresh-crude intake. Part of the same material passes through both units. Secondary units may also process imported intermediates, so their boundaries require separate feed accounting. Calendar-day and stream-day ratings must also remain distinct. The linked capacity guide explains those denominators; the density guide explains compatible mass–volume conversion. A mass-balance calculation cannot validate a nameplate rating, demonstrate that a unit is available today or convert a product-storage volume into crude-distillation capacity.","An actual boundary example is Nashpa in Pakistan’s Karak district. Joint-venture participant GHPL describes an integrated oil and gas processing facility with LPG extraction, reporting gas, crude/condensate handling and LPG on different measurement bases. A liquid-handling figure expressed in barrels per day does not, by that unit alone, establish atmospheric crude-distillation capacity. Field separation, gas treatment and liquid handling must retain their own process identities in an engineering comparison. The 11 November 2026 Atlas review therefore classifies this record as field/gas processing and preserves its unknown operating state and absent crude-distillation capacity value. A historical commissioning account does not establish present availability. The direct facility record and participant’s project description allow readers to inspect that scope without inventing a well-to-plant connection."]},{"heading":"Use plant documents within their actual scope","paragraphs":["Angola’s 2024 sector yearbook separately records crude deliveries to Malongo’s crude-distillation plant and production of refined products. Those headings support process identity, but dividing the two totals without inventory and other-stream reconciliation does not close an engineering material balance. At Naftan, UNIS documents AT-8 crude distillation and a dated reconstruction project. The equipment number does not define current throughput; the page’s historical ratings need their own scopes. These reviewed Atlas records retain their existing capacity and operating-state fields. Similarly, stopped crude units and remaining MTBE/intermediate processing at Tisza must be distinguished from whole-site closure."]},{"heading":"Make the calculation auditable","paragraphs":["An auditable balance preserves stream identity, quantity, unit, reference temperature and pressure, measurement period, inventory treatment and source. Keep measured observations separate from assumed inputs and calculated outputs. Investigate a nonzero residual through missing streams, incompatible conditions, stock movements and measurement uncertainty before calling it a process loss or gain. This example supplies no uncertainty estimate because its inputs are prescribed, not measured; additional decimal places are calculation precision only. It also supplies no refinery margin, energy-efficiency score or operating forecast. The source links, direct facility records, accessible chart table and related engineering guides let readers trace each distinct part of the analysis."]}],"text":"Refinery Mass Balance and Processing Gain: Why More Volume Does Not Mean More Mass\n\nA reproducible liquid-density example explains refinery processing gain, mass conservation, yield definitions and the boundary between crude intake and secondary-unit throughput.\n\nRefining can produce a larger liquid volume than the volume of crude supplied. That observation does not, by itself, establish extra mass, high energy efficiency or spare crude-processing capacity. Volume depends on density and reporting conditions, while a material balance must account for every relevant input, output and change in inventory.\n\nThis guide combines EIA definitions with a deliberately simplified, hypothetical batch calculation. All supplied densities refer to stable liquids at the same assumed 15 °C and 101.325 kPa. They are prescribed example inputs, not measured assays or density corrections derived from API gravity. The chart is calculated from those inputs; the editorial illustration depicts no real facility or engineering design.\n\nChoose the boundary and the reporting period\n\nFirst decide whether the balance covers a distillation unit, a conversion unit, a tank system or the entire refinery. Identify the calendar interval and the inventory included at its start and end. Crude delivered to a terminal need not equal crude charged to a process during that interval: some may enter or leave storage. Products manufactured need not equal products dispatched. A comparison of two annual totals therefore needs their definitions, not merely matching years. Keep the mass basis, volume reference conditions and time denominator alongside the values. A figure in tonnes is not interchangeable with barrels, and a batch volume has no daily-rate meaning until a time basis is supplied.\n\nWrite the material balance before calculating yield\n\nFor a defined period, the total mass equation is ΔM = Σm_in − Σm_out, where ΔM is the increase in inventory inside the boundary. At steady inventory, inputs and outputs balance. In a real refinery, the chosen boundary may require imported hydrogen, other feedstocks, water or steam, gas products, recovered sulfur, wastewater, fuel consumed and losses to be accounted for. Streams excluded from a hydrocarbon-only reporting convention must be identified. Chemical reactions rearrange material; they do not remove the need to balance mass. Heat duty, power and economic margin are separate balances. A high volumetric yield alone cannot establish thermal efficiency or profitability. If combustion equipment is inside the total-mass boundary, combustion air and flue gas must also be included.\n\nSpecify the hypothetical batch\n\nAssume 100,000 kg of feed with density 850 kg/m³. The output is prescribed as three separate liquid parcels: 45,000 kg at 740 kg/m³, 40,000 kg at 840 kg/m³ and 15,000 kg at 980 kg/m³. Call them light, middle and heavy liquids rather than assigning measured commercial product specifications. Their masses add exactly to 100,000 kg. The example deliberately excludes gas, water, sulfur products, fuel consumption, losses, additional feeds and inventory accumulation. It is a density-arithmetic exercise, not a refinery simulation, an achievable yield slate or a prediction for any mapped plant. Actual process design would need composition, reaction chemistry, phase behaviour and an energy balance.\n\nCalculate each liquid volume reproducibly\n\nUse V = m/ρ, with mass in kilograms and density in kg/m³, so the result is in cubic metres. The feed volume is 100000/850 = 117.647059 m³ after rounding. The light parcel occupies 45000/740 = 60.810811 m³; the middle parcel occupies 40000/840 = 47.619048 m³; and the heavy parcel occupies 15000/980 = 15.306122 m³. Retaining unrounded intermediate values gives a total product volume of 123.735981 m³. The accompanying chart compares this total with the feed volume on the same reference basis. It does not add a total row to its own components, compare gas standard volume with liquid volume or imply a daily throughput.\n\nSeparate volumetric increase from mass residual\n\nThe calculated volume difference is 6.088922 m³. The relative increase is (V_out/V_in − 1) × 100 = 5.175584%, or 5.18% after rounding. The mass residual remains 100000 − (45000 + 40000 + 15000) = 0 kg. The larger sum of separate product volumes follows from the supplied mass distribution and densities. It is not extra material. These parcels have not been mixed together, so no volume-additive blending law is being assumed. EIA’s January 2024 refining-model description explains processing gain through conversion of heavy feeds to lower-density products. Our arithmetic illustrates the density principle; it does not reproduce an observed EIA gain series or model the chemistry that creates a real product slate.\n\nRead the yield definition used by the dataset\n\nA mass fraction, a liquid-volume fraction and an official refinery-yield statistic are different quantities. EIA’s current glossary defines its denominator using crude oil, hydrogen, other hydrocarbons and net unfinished-oil inputs, and specifies adjustments for finished motor gasoline, aviation gasoline and distillate fuel oil. It also explains a methodological change for data before January 2009. Consequently, the example’s 45% light-liquid mass share is not an EIA gasoline yield. For comparisons across reports or years, retain product scope, denominator, net-versus-gross treatment, stock changes and method version. Do not silently harmonise a published statistic by substituting a convenient denominator.\n\nDo not add serial unit capacities\n\nSuppose a hypothetical primary unit accepts 100,000 bbl/day and a vacuum unit treating its residue has a 50,000 bbl/day rating. Their sum does not establish 150,000 bbl/day of fresh-crude intake. Part of the same material passes through both units. Secondary units may also process imported intermediates, so their boundaries require separate feed accounting. Calendar-day and stream-day ratings must also remain distinct. The linked capacity guide explains those denominators; the density guide explains compatible mass–volume conversion. A mass-balance calculation cannot validate a nameplate rating, demonstrate that a unit is available today or convert a product-storage volume into crude-distillation capacity.\n\nAn actual boundary example is Nashpa in Pakistan’s Karak district. Joint-venture participant GHPL describes an integrated oil and gas processing facility with LPG extraction, reporting gas, crude/condensate handling and LPG on different measurement bases. A liquid-handling figure expressed in barrels per day does not, by that unit alone, establish atmospheric crude-distillation capacity. Field separation, gas treatment and liquid handling must retain their own process identities in an engineering comparison. The 11 November 2026 Atlas review therefore classifies this record as field/gas processing and preserves its unknown operating state and absent crude-distillation capacity value. A historical commissioning account does not establish present availability. The direct facility record and participant’s project description allow readers to inspect that scope without inventing a well-to-plant connection.\n\nUse plant documents within their actual scope\n\nAngola’s 2024 sector yearbook separately records crude deliveries to Malongo’s crude-distillation plant and production of refined products. Those headings support process identity, but dividing the two totals without inventory and other-stream reconciliation does not close an engineering material balance. At Naftan, UNIS documents AT-8 crude distillation and a dated reconstruction project. The equipment number does not define current throughput; the page’s historical ratings need their own scopes. These reviewed Atlas records retain their existing capacity and operating-state fields. Similarly, stopped crude units and remaining MTBE/intermediate processing at Tisza must be distinguished from whole-site closure.\n\nMake the calculation auditable\n\nAn auditable balance preserves stream identity, quantity, unit, reference temperature and pressure, measurement period, inventory treatment and source. Keep measured observations separate from assumed inputs and calculated outputs. Investigate a nonzero residual through missing streams, incompatible conditions, stock movements and measurement uncertainty before calling it a process loss or gain. This example supplies no uncertainty estimate because its inputs are prescribed, not measured; additional decimal places are calculation precision only. It also supplies no refinery margin, energy-efficiency score or operating forecast. The source links, direct facility records, accessible chart table and related engineering guides let readers trace each distinct part of the analysis.\n\nTechnical and economic analysis\n\nAnalysis as of: 2026-11-11\n\nEvidence cutoff: 2026-11-11\n\nOutlook horizon: Hypothetical batch mass and volume balance\n\nIllustrative sensitivity\n\nHypothetical liquid volumes: equal total mass of 100,000 kg\n\nCalculated, not observed: V = m/ρ. Feed: 100000/850; separate products: 45000/740 + 40000/840 + 15000/980, in m³. Prescribed stable-liquid densities at assumed 15 °C and 101.325 kPa; no inventory change or additional streams. Total mass is equal; this is not a process simulation or measured plant yield.\n\nThese calculations illustrate stated assumptions; they are not observations or a calibrated forecast.\n\nFeed liquid: 117.6471 cubic metres\n\nSeparate products: total: 123.736 cubic metres","category":"energy","region":"world","topics":["oil","gas"],"eventDate":"2026-11-11","eventDateBasis":"analysis-as-of-date","publishedAt":"2026-11-11T13:10:07Z","modifiedAt":"2026-11-11T13:51:29Z","publicationBasis":"first-publication","preparedAt":"2026-11-11T13:00:08Z","sourcePublishedAt":null,"translatedAt":null,"sources":[{"url":"https://www.eia.gov/analysis/handbook/pdf/STEO%20Petroleum%20Refining%20Model.pdf","name":"EIA — Short-Term Energy Outlook petroleum refining model, January 2024","checkedAt":"2026-11-11"},{"url":"https://www.eia.gov/tools/glossary/index.php?id=Refinery%20yield","name":"EIA — Refinery yield definition and methodological scope","checkedAt":"2026-11-11"},{"url":"https://www.eia.gov/petroleum/supply/annual/volume1/pdf/psmdefs.pdf","name":"EIA — Petroleum Supply definitions","checkedAt":"2026-11-11"},{"url":"https://c2a.portais.gov.ao/uploads/ANUARIO_DO_SECTOR_DOS_RECURSOS_MINERAIS_PETROLEO_E_GAS_2024_compressed_7a0233d8dc.pdf","name":"Angola MIREMPET — 2024 sector yearbook, Malongo crude deliveries and refined-product production","checkedAt":"2026-11-11"},{"url":"https://www.unis.cz/en/references/noad","name":"UNIS — Naftan AT-8 crude-distillation reconstruction reference","checkedAt":"2026-11-11"},{"url":"https://www.tiszaujvaros.hu/images/bizjel/mol.pdf","name":"MOL — Tisza refinery public safety report, stopped crude-distillation units and remaining activities","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-352835608","name":"Wellficent Atlas — Malongo topping record","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-163923181","name":"Wellficent Atlas — Naftan record","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-relation-21185775","name":"Wellficent Atlas — Tisza record","checkedAt":"2026-11-11"},{"url":"https://ghpl.com.pk/projects/","name":"GHPL — Nashpa integrated oil/gas processing and LPG extraction","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-604834410","name":"Wellficent Atlas — Nashpa field/gas processing record","checkedAt":"2026-11-11"}],"translations":{"en":"https://wellficent.com/en/news/refinery-mass-balance-processing-gain-engineering-guide","tr":"https://wellficent.com/tr/news/refinery-mass-balance-processing-gain-engineering-guide","ar":"https://wellficent.com/ar/news/refinery-mass-balance-processing-gain-engineering-guide","fr":"https://wellficent.com/fr/news/refinery-mass-balance-processing-gain-engineering-guide","es":"https://wellficent.com/es/news/refinery-mass-balance-processing-gain-engineering-guide","ru":"https://wellficent.com/ru/news/refinery-mass-balance-processing-gain-engineering-guide","pt":"https://wellficent.com/pt/news/refinery-mass-balance-processing-gain-engineering-guide"},"corrections":[{"at":"2026-11-11T13:51:29Z","language":"en","text":"Add a source-verified Nashpa case distinguishing field oil/gas and LPG processing from crude-distillation capacity, with the participant’s project source and direct Atlas record; preserve calculations, image and first publication."}],"locations":[],"type":"analysis","analysis":{"asOf":"2026-11-11","kind":"technical-economic","chart":{"kind":"illustrative","note":{"ar":"قيم محسوبة لا مرصودة: V = m/ρ. اللقيم: 100000/850؛ المنتجات المنفصلة: 45000/740 + 40000/840 + 15000/980، بوحدة m³. كثافات سوائل مستقرة مفروضة عند 15 °C و101.325 kPa افتراضياً؛ بلا تغير مخزون أو تيارات إضافية. الكتلة الكلية متساوية؛ ليست محاكاة عملية أو مردود منشأة مقاساً.","en":"Calculated, not observed: V = m/ρ. Feed: 100000/850; separate products: 45000/740 + 40000/840 + 15000/980, in m³. Prescribed stable-liquid densities at assumed 15 °C and 101.325 kPa; no inventory change or additional streams. Total mass is equal; this is not a process simulation or measured plant yield.","es":"Cálculo, no observación: V = m/ρ. Alimentación: 100000/850; productos separados: 45000/740 + 40000/840 + 15000/980, en m³. Densidades prescritas de líquidos estables a 15 °C y 101,325 kPa supuestos; sin cambio de inventario ni corrientes adicionales. Masa total igual; no es simulación de proceso ni rendimiento medido.","fr":"Calcul, non observation : V = m/ρ. Charge : 100000/850 ; produits séparés : 45000/740 + 40000/840 + 15000/980, en m³. Densités de liquides stables prescrites à 15 °C et 101,325 kPa supposés ; ni variation de stock ni flux supplémentaire. Masse totale égale ; ni simulation de procédé ni rendement de site mesuré.","pt":"Cálculo, não observação: V = m/ρ. Alimentação: 100000/850; produtos separados: 45000/740 + 40000/840 + 15000/980, em m³. Densidades prescritas de líquidos estáveis a 15 °C e 101,325 kPa supostos; sem alteração de inventário ou correntes adicionais. Massa total igual; não é simulação de processo nem rendimento medido.","ru":"Расчёт, не наблюдение: V = m/ρ. Сырьё: 100000/850; отдельные продукты: 45000/740 + 40000/840 + 15000/980, в м³. Заданные плотности стабильных жидкостей при условных 15 °C и 101,325 кПа; без изменения запасов и дополнительных потоков. Общая масса одинакова; это не модель процесса и не измеренный выход завода.","tr":"Hesaplanmıştır, gözlem değildir: V = m/ρ. Besleme: 100000/850; ayrı ürünler: 45000/740 + 40000/840 + 15000/980, m³. Varsayımsal 15 °C ve 101,325 kPa koşullarında verilen kararlı sıvı yoğunlukları; stok değişimi veya ek akış yoktur. Toplam kütle eşittir; proses simülasyonu veya ölçülmüş tesis verimi değildir."},"rows":[{"label":{"ar":"سائل اللقيم","en":"Feed liquid","es":"Líquido de alimentación","fr":"Liquide d’alimentation","pt":"Líquido de alimentação","ru":"Жидкое сырьё","tr":"Besleme sıvısı"},"value":117.647059},{"label":{"ar":"المنتجات المنفصلة: المجموع","en":"Separate products: total","es":"Productos separados: total","fr":"Produits séparés : total","pt":"Produtos separados: total","ru":"Отдельные продукты: всего","tr":"Ayrı ürünler: toplam"},"value":123.735981}],"unit":"m³","title":{"ar":"أحجام سوائل افتراضية بكتلة كلية متساوية قدرها 100,000 kg","en":"Hypothetical liquid volumes: equal total mass of 100,000 kg","es":"Volúmenes líquidos hipotéticos: igual masa total de 100.000 kg","fr":"Volumes liquides fictifs : même masse totale de 100 000 kg","pt":"Volumes líquidos hipotéticos: massa total igual de 100.000 kg","ru":"Условные объёмы жидкостей: одинаковая суммарная масса 100 000 кг","tr":"Varsayımsal sıvı hacimleri: eşit toplam kütle, 100.000 kg"},"unitLabel":{"ar":"متر مكعب","en":"cubic metres","es":"metros cúbicos","fr":"mètres cubes","pt":"metros cúbicos","ru":"кубические метры","tr":"metreküp"}},"horizon":"Hypothetical batch mass and volume balance","horizonLabel":{"ar":"ميزان كتلة وحجم لدفعة افتراضية","en":"Hypothetical batch mass and volume balance","es":"Balance de masa y volumen de un lote hipotético","fr":"Bilan de masse et de volume d’un lot fictif","pt":"Balanço de massa e volume de um lote hipotético","ru":"Массовый и объёмный баланс условной партии","tr":"Varsayımsal parti kütle ve hacim dengesi"},"evidenceCutoff":"2026-11-11"},"relatedArticles":[{"canonicalSlug":"refinery-capacity-calendar-stream-day-engineering-guide","url":"https://wellficent.com/en/news/refinery-capacity-calendar-stream-day-engineering-guide","title":"Refinery capacity: calendar day, stream day and actual throughput","language":"en"},{"canonicalSlug":"api-gravity-density-mass-volume-engineering-guide","url":"https://wellficent.com/en/news/api-gravity-density-mass-volume-engineering-guide","title":"API Gravity, Density and Mass–Volume Conversion: A Petroleum Engineering Guide","language":"en"},{"canonicalSlug":"refinery-terminal-status-permit-data-engineering-guide","url":"https://wellficent.com/en/news/refinery-terminal-status-permit-data-engineering-guide","title":"Refinery or Fuel Terminal? How to Read Plant Status, Permits and Engineering Data","language":"en"}],"image":{"url":"https://wellficent.com/media/8f1e0a8ea6594502fd88d747e770b30372dad95db5ea2cd889447c344f50965a.webp","width":1536,"height":1024,"alt":"Conceptual refinery process area with two distillation towers, supported pipes and a separate heater; no named facility or engineered process design.","credit":"Wellficent / Codex imagegen — AI-generated conceptual illustration; not an authentic project photograph, site survey or process schematic.","licenseUrl":"https://openai.com/policies/terms-of-use/"}}},{"requestedLanguage":"en","fallback":false,"record":{"id":"refinery-terminal-status-permit-data-engineering-guide","canonicalSlug":"refinery-terminal-status-permit-data-engineering-guide","url":"https://wellficent.com/en/news/refinery-terminal-status-permit-data-engineering-guide","language":"en","title":"Refinery or Fuel Terminal? How to Read Plant Status, Permits and Engineering Data","summary":"Primary-source cases from North Pole, Lumberton and Bakersfield explain why fuel-tax registration, cleanup status and tank inventory do not establish operating crude-refining capacity.","body":["A facility can retain “refinery” in its name, appear in a fuel-tax register and have an active environmental case after its crude-processing equipment stops operating. These statements concern different attributes. Treating them as interchangeable creates false refinery counts, misleading capacity comparisons and incorrect links between wells and downstream infrastructure.","This engineering review separates process identity, site identity, operating observations and reporting dates. It uses official documents and operator descriptions checked on 11 November 2026. The tank example is explicitly hypothetical, and the illustration depicts an unnamed conceptual terminal. Neither supplies measurements for any named facility. The corresponding reviewed Atlas records preserve their source history and unknown operating-state fields."],"keyPoints":[],"sections":[{"heading":"Define the process before counting the plant","paragraphs":["Start with what crosses the process boundary. Crude distillation, condensate fractionation, asphalt blending and fuel storage can all involve tanks, heaters, pumps and petroleum products, but those shared features do not establish the same industrial activity. A product list is insufficient: asphalt can come from a crude refinery or be received and blended at a terminal. Petro Rabigh explicitly identifies Arabian Light crude as feed; its integrated petrochemical activity does not erase the refining function. Conversely, a distribution business does not gain crude-processing capacity because its company name contains “oil.” Record the documented feed and process separately from ownership, current availability and any numerical rating.","The word “crude” also needs its material qualifier. University of Oriente research from 2011 and 2018 describes ERASOL in Santiago de Cuba as a refinery of crude soybean oil for edible vegetable oil. This is not petroleum distillation or evidence of biofuel production. The applicant’s environmental-control programme for Varvarinskoye, covering 2023–2028, describes gold-copper ore processing; its separate submission explanation lists crushing, grinding, flotation, cyanidation with carbon adsorption and gold smelting. Neither ore tonnage nor edible-oil output belongs in a crude-refinery capacity total. A research sample, proposed treatment improvement or submitted monitoring programme is also not proof of current compliance, permit approval or present operation.","Feed identity also limits comparisons between petroleum facilities. Farab's firsthand account identifies South Pars gas condensate as the feed for Persian Gulf Star and separates utility and process areas; a sulfur-package supplier places that named project west of the existing Bandar Abbas refinery. Its product slate does not make a condensate-feed rating an atmospheric petroleum-crude rating. Somerset illustrates a different change: Kentucky's 2024 energy-security plan describes soybean processing, biodiesel and fuel-terminal activity, while CRC's history and its equipment supplier document the former refinery's conversion. Soy crushing, biodiesel production, blending and petroleum storage remain distinct operations; none supplies a current crude-distillation capacity or proves today's unit availability.","Historical process evidence must keep its original time and boundary. Jiangsu Yanxin's project reference dated 29 April 2010 identifies an atmospheric furnace for Dagang's acid-crude adaptation project; Tsinghua's firsthand research profile separately documents atmospheric/vacuum process modelling there. This confirms crude-refinery identity, while project tonnage is not today's refinery capacity. At Bari, ExxonMobil's history and Eni's archive corroborate STANIC's historical refinery. Puglia's decision of 15 December 2008, published on 15 January 2009, authorises characterisation of the DEINT area with sampling and groundwater requirements. It neither certifies completed remediation nor establishes a whole-site closure date or current operating permit. An archive image's material date is also distinct from its publication date and reuse rights.","Read the publication field rather than deriving it from a document path. CNPC's firsthand Changqing manager discussions display 21 November 2024 and 25 December 2024; the latter sits under a 2025/01/06 URL. Their refining and product-planning descriptions corroborate historical refinery identity without establishing today's unit availability. Separately stored light fractions are process context, not an independently verified crude-capacity measurement. National market forecasts and another company's ratings in a multi-company discussion must not migrate into the Changqing record. An inaccessible technical report remains unread even when other primary documents subsequently support the classification."]},{"heading":"Read the purpose of each register","paragraphs":["The IRS document headed Active Fuel Refineries, dated 30 August 2026, is a fuel-tax registration inventory. It includes Hunt Southland at Lumberton and North Pole Refinery, as well as separately named renewable-fuel facilities. Its title must not be treated as an engineering definition of operating atmospheric crude distillation. Read the address and registration context, then examine plant-specific process evidence. The separate IRS terminal inventory is also a registration source; appearing in both inventories need not imply two physical installations. Deduplicate only with documented identity evidence. A tax record, environmental permit and operator page answer different questions, and disagreement between their labels requires review rather than automatic replacement of one field by another."]},{"heading":"North Pole: an active case is not an active crude unit","paragraphs":["Alaska DEC’s North Pole page, with a summary updated on 1 May 2026, describes the former Flint Hills refinery as the Marathon Terminal and dates the end of refining to 2014. The page’s Active field belongs to its contaminated-sites record. It therefore describes an environmental case, not verified current crude-unit operation. The same source separates historical activity from ongoing groundwater work. This review uses the explicit terminal reuse to correct the activity class while preserving unknown operating status in the dataset. The nearby Petro Star refinery has a separate IRS entry and address; its activity cannot be transferred to the former Flint Hills record merely because both are in North Pole."]},{"heading":"Lumberton and Tryon: storage and dispatch are distinct activities","paragraphs":["Hunt’s own logistics page identifies the Lumberton Terminal as manufacturing emulsified asphalt and storing and dispatching paving-grade asphalt. Its contact page places the site at 7539 Highway 11, matching the retained map address and distinguishing it from Sandersville and Tuscaloosa. These positive process descriptions support the terminal class despite the older refinery naming. Neal Oil describes bulk propane, diesel and gasoline distribution in Tryon. The county hazard plan lists its fixed chemical-storage locations using a 2020 inventory; the document itself is dated 2021 despite a 2026 download path. Such historical storage evidence is not a current compliance certificate. Loading counts and tank capacities remain their own quantities."]},{"heading":"Bakersfield: match the street and the well function","paragraphs":["EPA’s SJR draft Class I injection-permit fact sheet describes heavy-crude-derived manufacture at Shell Street in northern Bakersfield. It identifies WD-1 as a wastewater-disposal well and gives a refinery-site location. The IRS inventory separately lists San Joaquin Refining at 3542 Shell Street and Central Valley Renewable Fuels at 6451 Rosedale Highway. A conversion at the second location cannot be assigned to the first solely through a city-name match. Similarly, the disposal well is not an oil-production observation. The draft describes proposed permit conditions and a proposed additional well; it does not by itself prove that those conditions became final or that a future well was drilled. No verified Well Atlas production-record join has been established here, so none is invented."]},{"heading":"Calculate inventory cover without creating refinery capacity","paragraphs":["Assume a hypothetical usable inventory V = 24,000 bbl, expressed on the same liquid-volume reference basis as a constant dispatch rate Q. The ratio τ = V/Q has units of days. At 3,000, 6,000 and 12,000 bbl/day, it gives 8, 4 and 2 days respectively; the chart reproduces these three calculations. For a no-inflow, constant-outflow example, dV/dt = −Q and the time to exhaust that usable inventory is V/Q. With replenishment, the same ratio is only nominal inventory cover, not a stockout forecast or a measured residence-time distribution. Tank heels, unavailable product, line fill and operating reserves must already be excluded from usable inventory. All three dispatch rates are assumed scenarios, not plant observations. Neither the inventory in barrels nor its ratio to dispatch is crude-distillation nameplate capacity."]},{"heading":"Keep annual feed, projects and present availability apart","paragraphs":["Uzbekneftegaz’s May 2025 offering circular describes Bukhara’s mixed oil-and-condensate processing. The government’s 4 November 2026 account locates it in Karaulbazar and describes proposed hydrotreating, isomerisation and expansion. The location and feed evidence support refinery identity, but a planned expansion is not a completed process unit. An annual mass rating needs a documented feed-density and time basis before comparison with daily liquid volume; condensate and crude must retain their declared scope. The linked capacity and API-gravity guides show those separate calculations. A dated production announcement likewise remains an observation for its stated date, rather than a guarantee of uninterrupted operation on every subsequent day.","Historical refinery identity and present operation require separate decisions. Aruba’s government statement of 11 November 2025 records the decision to permanently close the oil chapter at the San Nicolas refinery area and says the CITGO rehabilitation effort ended definitively in 2019. Proposed alternative industries are not commissioned replacement plants. For Isla in Curaçao, a refinery-engineer case study explicitly describes atmospheric and vacuum distillation in the CD3 crude-unit model. That establishes historical process identity, not current availability or a current site-wide rating. Its actual publication date remains unknown; an embedded filename and a hosting-path date cannot supply it. These source reviews and direct Atlas references were added on 11 November 2026, preserving this guide’s first publication.","Location must be matched as carefully as process. Rome's civil-protection table lists DE.CO separately from Raffineria di Roma, ENI and Lampogas. The DE.CO notification NN006/4027, printed on 25 August 2023, describes gasoline/diesel receipt, storage and tanker loading without petroleum processing. This evidence supports the specifically matched terminal feature; it does not classify the wider industrial district or merge neighbouring legal operators. Conversely, Rosnedra's 2021 resources report, published in 2022, documents oil refining at Kirishi and supports that historical refinery identity. It is not a current operating-status report.","Natural gasoline is another important feed distinction. Pacifpetrol describes recovering heavier hydrocarbons from natural gas at its Planta de Gasolina, separately from Casa Bomba's crude receipt, dehydration, storage and pumping. The February 2007 EPN field study's company base map identifies the gas plant separately from Casa Bomba (PDF page 73, printed page 59). This supports qualitative site matching; the map does not explicitly identify its grid datum and zone, so it cannot justify new surveyed coordinates or an exact boundary. Crude dehydration removes water upstream; it does not demonstrate atmospheric crude distillation at the gas plant. The retained record therefore uses field/gas processing, with unknown current operating status and no numerical crude capacity. Historical mapping and undated departmental descriptions cannot prove current unit availability.","Marine fuel handling needs the same separation of scopes. PNG's March 2007 marine-spill plan describes Mobil's imported refined fuels discharged into shore tanks at Lae. Puma's Annual Report 2020 names its Speybank and Aircorps terminals there; the installation supplier describes solar work in 2021. The report's construction label belongs to the solar project, not the operating state of an entire terminal. Electrical power ratings and countrywide delivery rates are not site crude-distillation capacity. The old plan's filename and internal approval wording do not independently establish its present legal applicability. Port illustrations are not operator-specific surveyed boundaries, so generic mapped names retain their location uncertainty, unknown operating status and null crude capacity."]},{"heading":"Build connections that the evidence can support","paragraphs":["A reproducible facility review retains the map ID, source URL, document date, access date, process description and reason for the decision. Keep earlier classifications in revision history. Link the reviewed facility record and relevant engineering explanation directly, while labelling unverified joins as unresolved. An operator’s portfolio is not proof of a physical supply route, and a shared town is not proof of a common plant. This seven-record review retains every existing facility ID and leaves capacities and operating states unchanged. It reduces uncertainty about activity classification, without turning that narrower improvement into new production, ownership or supply-chain claims. Reassessment remains necessary when dated plant-specific evidence changes. A retained source record identifies a documented map feature; it does not certify a surveyed physical boundary."]}],"text":"Refinery or Fuel Terminal? How to Read Plant Status, Permits and Engineering Data\n\nPrimary-source cases from North Pole, Lumberton and Bakersfield explain why fuel-tax registration, cleanup status and tank inventory do not establish operating crude-refining capacity.\n\nA facility can retain “refinery” in its name, appear in a fuel-tax register and have an active environmental case after its crude-processing equipment stops operating. These statements concern different attributes. Treating them as interchangeable creates false refinery counts, misleading capacity comparisons and incorrect links between wells and downstream infrastructure.\n\nThis engineering review separates process identity, site identity, operating observations and reporting dates. It uses official documents and operator descriptions checked on 11 November 2026. The tank example is explicitly hypothetical, and the illustration depicts an unnamed conceptual terminal. Neither supplies measurements for any named facility. The corresponding reviewed Atlas records preserve their source history and unknown operating-state fields.\n\nDefine the process before counting the plant\n\nStart with what crosses the process boundary. Crude distillation, condensate fractionation, asphalt blending and fuel storage can all involve tanks, heaters, pumps and petroleum products, but those shared features do not establish the same industrial activity. A product list is insufficient: asphalt can come from a crude refinery or be received and blended at a terminal. Petro Rabigh explicitly identifies Arabian Light crude as feed; its integrated petrochemical activity does not erase the refining function. Conversely, a distribution business does not gain crude-processing capacity because its company name contains “oil.” Record the documented feed and process separately from ownership, current availability and any numerical rating.\n\nThe word “crude” also needs its material qualifier. University of Oriente research from 2011 and 2018 describes ERASOL in Santiago de Cuba as a refinery of crude soybean oil for edible vegetable oil. This is not petroleum distillation or evidence of biofuel production. The applicant’s environmental-control programme for Varvarinskoye, covering 2023–2028, describes gold-copper ore processing; its separate submission explanation lists crushing, grinding, flotation, cyanidation with carbon adsorption and gold smelting. Neither ore tonnage nor edible-oil output belongs in a crude-refinery capacity total. A research sample, proposed treatment improvement or submitted monitoring programme is also not proof of current compliance, permit approval or present operation.\n\nFeed identity also limits comparisons between petroleum facilities. Farab's firsthand account identifies South Pars gas condensate as the feed for Persian Gulf Star and separates utility and process areas; a sulfur-package supplier places that named project west of the existing Bandar Abbas refinery. Its product slate does not make a condensate-feed rating an atmospheric petroleum-crude rating. Somerset illustrates a different change: Kentucky's 2024 energy-security plan describes soybean processing, biodiesel and fuel-terminal activity, while CRC's history and its equipment supplier document the former refinery's conversion. Soy crushing, biodiesel production, blending and petroleum storage remain distinct operations; none supplies a current crude-distillation capacity or proves today's unit availability.\n\nHistorical process evidence must keep its original time and boundary. Jiangsu Yanxin's project reference dated 29 April 2010 identifies an atmospheric furnace for Dagang's acid-crude adaptation project; Tsinghua's firsthand research profile separately documents atmospheric/vacuum process modelling there. This confirms crude-refinery identity, while project tonnage is not today's refinery capacity. At Bari, ExxonMobil's history and Eni's archive corroborate STANIC's historical refinery. Puglia's decision of 15 December 2008, published on 15 January 2009, authorises characterisation of the DEINT area with sampling and groundwater requirements. It neither certifies completed remediation nor establishes a whole-site closure date or current operating permit. An archive image's material date is also distinct from its publication date and reuse rights.\n\nRead the publication field rather than deriving it from a document path. CNPC's firsthand Changqing manager discussions display 21 November 2024 and 25 December 2024; the latter sits under a 2025/01/06 URL. Their refining and product-planning descriptions corroborate historical refinery identity without establishing today's unit availability. Separately stored light fractions are process context, not an independently verified crude-capacity measurement. National market forecasts and another company's ratings in a multi-company discussion must not migrate into the Changqing record. An inaccessible technical report remains unread even when other primary documents subsequently support the classification.\n\nRead the purpose of each register\n\nThe IRS document headed Active Fuel Refineries, dated 30 August 2026, is a fuel-tax registration inventory. It includes Hunt Southland at Lumberton and North Pole Refinery, as well as separately named renewable-fuel facilities. Its title must not be treated as an engineering definition of operating atmospheric crude distillation. Read the address and registration context, then examine plant-specific process evidence. The separate IRS terminal inventory is also a registration source; appearing in both inventories need not imply two physical installations. Deduplicate only with documented identity evidence. A tax record, environmental permit and operator page answer different questions, and disagreement between their labels requires review rather than automatic replacement of one field by another.\n\nNorth Pole: an active case is not an active crude unit\n\nAlaska DEC’s North Pole page, with a summary updated on 1 May 2026, describes the former Flint Hills refinery as the Marathon Terminal and dates the end of refining to 2014. The page’s Active field belongs to its contaminated-sites record. It therefore describes an environmental case, not verified current crude-unit operation. The same source separates historical activity from ongoing groundwater work. This review uses the explicit terminal reuse to correct the activity class while preserving unknown operating status in the dataset. The nearby Petro Star refinery has a separate IRS entry and address; its activity cannot be transferred to the former Flint Hills record merely because both are in North Pole.\n\nLumberton and Tryon: storage and dispatch are distinct activities\n\nHunt’s own logistics page identifies the Lumberton Terminal as manufacturing emulsified asphalt and storing and dispatching paving-grade asphalt. Its contact page places the site at 7539 Highway 11, matching the retained map address and distinguishing it from Sandersville and Tuscaloosa. These positive process descriptions support the terminal class despite the older refinery naming. Neal Oil describes bulk propane, diesel and gasoline distribution in Tryon. The county hazard plan lists its fixed chemical-storage locations using a 2020 inventory; the document itself is dated 2021 despite a 2026 download path. Such historical storage evidence is not a current compliance certificate. Loading counts and tank capacities remain their own quantities.\n\nBakersfield: match the street and the well function\n\nEPA’s SJR draft Class I injection-permit fact sheet describes heavy-crude-derived manufacture at Shell Street in northern Bakersfield. It identifies WD-1 as a wastewater-disposal well and gives a refinery-site location. The IRS inventory separately lists San Joaquin Refining at 3542 Shell Street and Central Valley Renewable Fuels at 6451 Rosedale Highway. A conversion at the second location cannot be assigned to the first solely through a city-name match. Similarly, the disposal well is not an oil-production observation. The draft describes proposed permit conditions and a proposed additional well; it does not by itself prove that those conditions became final or that a future well was drilled. No verified Well Atlas production-record join has been established here, so none is invented.\n\nCalculate inventory cover without creating refinery capacity\n\nAssume a hypothetical usable inventory V = 24,000 bbl, expressed on the same liquid-volume reference basis as a constant dispatch rate Q. The ratio τ = V/Q has units of days. At 3,000, 6,000 and 12,000 bbl/day, it gives 8, 4 and 2 days respectively; the chart reproduces these three calculations. For a no-inflow, constant-outflow example, dV/dt = −Q and the time to exhaust that usable inventory is V/Q. With replenishment, the same ratio is only nominal inventory cover, not a stockout forecast or a measured residence-time distribution. Tank heels, unavailable product, line fill and operating reserves must already be excluded from usable inventory. All three dispatch rates are assumed scenarios, not plant observations. Neither the inventory in barrels nor its ratio to dispatch is crude-distillation nameplate capacity.\n\nKeep annual feed, projects and present availability apart\n\nUzbekneftegaz’s May 2025 offering circular describes Bukhara’s mixed oil-and-condensate processing. The government’s 4 November 2026 account locates it in Karaulbazar and describes proposed hydrotreating, isomerisation and expansion. The location and feed evidence support refinery identity, but a planned expansion is not a completed process unit. An annual mass rating needs a documented feed-density and time basis before comparison with daily liquid volume; condensate and crude must retain their declared scope. The linked capacity and API-gravity guides show those separate calculations. A dated production announcement likewise remains an observation for its stated date, rather than a guarantee of uninterrupted operation on every subsequent day.\n\nHistorical refinery identity and present operation require separate decisions. Aruba’s government statement of 11 November 2025 records the decision to permanently close the oil chapter at the San Nicolas refinery area and says the CITGO rehabilitation effort ended definitively in 2019. Proposed alternative industries are not commissioned replacement plants. For Isla in Curaçao, a refinery-engineer case study explicitly describes atmospheric and vacuum distillation in the CD3 crude-unit model. That establishes historical process identity, not current availability or a current site-wide rating. Its actual publication date remains unknown; an embedded filename and a hosting-path date cannot supply it. These source reviews and direct Atlas references were added on 11 November 2026, preserving this guide’s first publication.\n\nLocation must be matched as carefully as process. Rome's civil-protection table lists DE.CO separately from Raffineria di Roma, ENI and Lampogas. The DE.CO notification NN006/4027, printed on 25 August 2023, describes gasoline/diesel receipt, storage and tanker loading without petroleum processing. This evidence supports the specifically matched terminal feature; it does not classify the wider industrial district or merge neighbouring legal operators. Conversely, Rosnedra's 2021 resources report, published in 2022, documents oil refining at Kirishi and supports that historical refinery identity. It is not a current operating-status report.\n\nNatural gasoline is another important feed distinction. Pacifpetrol describes recovering heavier hydrocarbons from natural gas at its Planta de Gasolina, separately from Casa Bomba's crude receipt, dehydration, storage and pumping. The February 2007 EPN field study's company base map identifies the gas plant separately from Casa Bomba (PDF page 73, printed page 59). This supports qualitative site matching; the map does not explicitly identify its grid datum and zone, so it cannot justify new surveyed coordinates or an exact boundary. Crude dehydration removes water upstream; it does not demonstrate atmospheric crude distillation at the gas plant. The retained record therefore uses field/gas processing, with unknown current operating status and no numerical crude capacity. Historical mapping and undated departmental descriptions cannot prove current unit availability.\n\nMarine fuel handling needs the same separation of scopes. PNG's March 2007 marine-spill plan describes Mobil's imported refined fuels discharged into shore tanks at Lae. Puma's Annual Report 2020 names its Speybank and Aircorps terminals there; the installation supplier describes solar work in 2021. The report's construction label belongs to the solar project, not the operating state of an entire terminal. Electrical power ratings and countrywide delivery rates are not site crude-distillation capacity. The old plan's filename and internal approval wording do not independently establish its present legal applicability. Port illustrations are not operator-specific surveyed boundaries, so generic mapped names retain their location uncertainty, unknown operating status and null crude capacity.\n\nBuild connections that the evidence can support\n\nA reproducible facility review retains the map ID, source URL, document date, access date, process description and reason for the decision. Keep earlier classifications in revision history. Link the reviewed facility record and relevant engineering explanation directly, while labelling unverified joins as unresolved. An operator’s portfolio is not proof of a physical supply route, and a shared town is not proof of a common plant. This seven-record review retains every existing facility ID and leaves capacities and operating states unchanged. It reduces uncertainty about activity classification, without turning that narrower improvement into new production, ownership or supply-chain claims. Reassessment remains necessary when dated plant-specific evidence changes. A retained source record identifies a documented map feature; it does not certify a surveyed physical boundary.\n\nTechnical and economic analysis\n\nAnalysis as of: 2026-11-11\n\nEvidence cutoff: 2026-11-11\n\nOutlook horizon: Facility evidence and inventory arithmetic\n\nIllustrative sensitivity\n\nHypothetical inventory cover: 24,000 bbl usable stock\n\nCalculated scenarios: τ = 24000 / Q, with Q = 3000, 6000 or 12000 bbl/day on a compatible liquid-volume basis. Assumed usable stock and constant dispatch; no measured facility data, stockout forecast or crude-distillation capacity.\n\nThese calculations illustrate stated assumptions; they are not observations or a calibrated forecast.\n\n3000 bbl/day: 8 days\n\n6000 bbl/day: 4 days\n\n12000 bbl/day: 2 days","category":"energy","region":"world","topics":["oil","gas"],"eventDate":"2026-11-11","eventDateBasis":"analysis-as-of-date","publishedAt":"2026-11-11T11:57:54Z","modifiedAt":"2026-11-11T20:20:02Z","publicationBasis":"first-publication","preparedAt":"2026-11-11T11:45:32Z","sourcePublishedAt":null,"translatedAt":null,"sources":[{"url":"https://www.irs.gov/pub/irs-sbse/rcn-db.pdf","name":"IRS — Active Fuel Refineries, 30 August 2026","checkedAt":"2026-11-11"},{"url":"https://www.irs.gov/pub/irs-sbse/tcn-db.pdf","name":"IRS — Active Fuel Terminals","checkedAt":"2026-11-11"},{"url":"https://dec.alaska.gov/spar/csp/sites/north-pole-refinery/","name":"Alaska DEC — North Pole contaminated-site case, summary updated 1 May 2026","checkedAt":"2026-11-11"},{"url":"https://www.huntrefining.com/logistics-terminal-operations.aspx","name":"Hunt — Lumberton Terminal process description","checkedAt":"2026-11-11"},{"url":"https://www.huntrefining.com/contact.aspx","name":"Hunt — Plant contact addresses","checkedAt":"2026-11-11"},{"url":"https://nealoil.com/propane-diesel-gas-delivery/","name":"Neal Oil — Tryon bulk fuel distribution","checkedAt":"2026-11-11"},{"url":"https://jeo.com/wp-content/uploads/2026/03/05_McPherson-County-Appendix.pdf","name":"McPherson County — 2021 hazard mitigation plan, 2020 fixed-storage inventory","checkedAt":"2026-11-11"},{"url":"https://www.epa.gov/system/files/documents/2025-07/r9uic-ca1-fy16-1-san-joaquin-refinery-ltd-factsheet-2020.pdf","name":"EPA — SJR draft Class I UIC permit fact sheet, R9UIC-CA1-FY16-1","checkedAt":"2026-11-11"},{"url":"https://www.petrorabigh.com/en/OurProducts/RefinedProducts","name":"Petro Rabigh — Arabian Light crude feed and refined products","checkedAt":"2026-11-11"},{"url":"https://webdev.ung.uz/media/allfiles/files/194fb03e11964234b49c7dfdd98a17be.pdf","name":"Uzbekneftegaz — May 2025 offering circular, Bukhara mixed oil/condensate feed","checkedAt":"2026-11-11"},{"url":"https://pakistan.mfa.uz/en/news/bukhara-oil-refinery-to-increase-production-of-high-quality-fuel","name":"Uzbekistan embassy — Bukhara project account, 4 November 2026","checkedAt":"2026-11-11"},{"url":"https://ghgdata.epa.gov/ghgp/html/2023.do?et=undefined&id=1006032","name":"EPA — Eagle Springs, 2023 facility reporting period","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-60950041","name":"Wellficent Atlas — Former Flint Hills North Pole record","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-910454887","name":"Wellficent Atlas — Hunt Lumberton record","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-relation-9649412","name":"Wellficent Atlas — SJR Shell Street record","checkedAt":"2026-11-11"},{"url":"https://www.redalyc.org/pdf/4455/445543772011.pdf","name":"University of Oriente — ERASOL soybean-oil process field study, 2011","checkedAt":"2026-11-11"},{"url":"https://www.redalyc.org/journal/4455/445558421007/445558421007.pdf","name":"University of Oriente — ERASOL location and wastewater study, 2018","checkedAt":"2026-11-11"},{"url":"https://ecoportal.kz/Public/PubHearings/LoadFile/74732","name":"Applicant environmental-control programme — Varvarinskoye, 2023–2028","checkedAt":"2026-11-11"},{"url":"https://ecoportal.kz/Public/PubHearings/LoadFile/113531","name":"Applicant submission explanation — Varvarinskoye mineral-processing scopes, 2023","checkedAt":"2026-11-11"},{"url":"https://www.gobierno.aw/en/aruba-opens-a-new-chapter-for-a-sustainable-future","name":"Government of Aruba — dated closure-policy statement, 11 November 2025","checkedAt":"2026-11-11","publishedAt":"2025-11-11"},{"url":"https://process-nmr.com/wp-content/uploads/2019/01/NPRA-NMR-and-Online-Optimization-at-ISLA.pdf","name":"Refineria Isla / Invensys — undated historical crude-unit engineering case study","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-203230406","name":"Wellficent Atlas — ERASOL edible-oil classification","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-432300177","name":"Wellficent Atlas — Varvarinskoye gold-copper processing","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-relation-5263426","name":"Wellficent Atlas — Aruba retained refinery and dated closure","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-26958365","name":"Wellficent Atlas — Isla historical refinery process identity","checkedAt":"2026-11-11"},{"url":"https://rosnedra.gov.ru/data/Files/File/8762.pdf","name":"Rosnedra — mineral resources in 2021, Moscow 2022; Kirishi oil refining","checkedAt":"2026-11-11"},{"url":"https://eec.ky.gov/Energy/Documents/KY%20Energy%20Security%20Plan%202024%20FINAL.pdf","name":"Kentucky Energy Security Plan 2024 — Somerset soybean, biodiesel and terminal scope","checkedAt":"2026-11-11"},{"url":"https://www.conrefco.com/fccp-about-21757","name":"Continental Refining Company — Somerset history and soy/biodiesel conversion","checkedAt":"2026-11-11"},{"url":"https://www.andersonintl.com/transforming-a-crude-oil-refinery-into-a-soybean-crush-plant/","name":"Anderson International — firsthand Somerset soybean-crush conversion","checkedAt":"2026-11-11"},{"url":"https://www.farab.com/en/portfolio/utility-and-process-areas-of-persian-gulf-star-refinery-project/","name":"Farab — Persian Gulf Star condensate feed and utility/process scope","checkedAt":"2026-11-11"},{"url":"https://sulf.ir/Projects/Portfolio/PersianGulfStar/?lang=en","name":"Sulfur-package supplier — Persian Gulf Star project narrative; package fields separately qualified","checkedAt":"2026-11-11"},{"url":"https://www.comune.roma.it/web-resources/cms/documents/RIR_DE.CO_2023.pdf","name":"Rome municipality — DE.CO notification NN006/4027, printed 25 August 2023","checkedAt":"2026-11-11"},{"url":"https://www.comune.roma.it/web-resources/cms/documents/Fasc1_InformazioniCarattereGenerale_2020.pdf","name":"Rome Civil Protection — individually named industrial locations, PDF p.189","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-relation-11366279","name":"Wellficent Atlas — Киришинефтеоргсинтез; independently reviewed process scope","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-676581243","name":"Wellficent Atlas — Somerset Refinery; independently reviewed process scope","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-489941810","name":"Wellficent Atlas — پالایشگاه ستاره خلیج فارس بندرعباس; independently reviewed process scope","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-24388724","name":"Wellficent Atlas — Raffineria Petrolifera; independently reviewed process scope","checkedAt":"2026-11-11"},{"url":"https://corporate.exxonmobil.com/locations/italy/our-history?content-lang=it","name":"ExxonMobil Italy — historical STANIC refineries at Bari and Livorno","checkedAt":"2026-11-11"},{"url":"https://archiviostorico.eni.com/aseni/it/explore/photos/IT-ENI-FT0001-0000002880","name":"Eni historical archive — Stanic, Raffineria di Bari; material dated 1950, photographs rights-reserved","checkedAt":"2026-11-11"},{"url":"https://burp.regione.puglia.it/documents/20135/402433/DETERMINAZIONE%2BDEL%2BDIRIGENTE%2BSERVIZIO%2BGESTIONE%2BRIFIUTI%2BE%2BBONIFICA%2B15%2Bdicembre%2B2008%2C%2Bn.%2B262%2B%28id%2B5084573%29.pdf/8c5d52ca-e009-3a2a-97d3-37469e5218f1?t=1622715200788","name":"Puglia official bulletin 15 January 2009 — DEINT characterisation decision 262 of 15 December 2008","checkedAt":"2026-11-11","publishedAt":"2009-01-15"},{"url":"https://en.chinayanxin.com/news/469.html","name":"Jiangsu Yanxin — Dagang atmospheric-furnace project reference, 29 April 2010","checkedAt":"2026-11-11","publishedAt":"2010-04-29"},{"url":"https://scholars.chemeng.tsinghua.edu.cn/RESEARCHS/system/files/staff/hexr/hexr.htm","name":"Tsinghua Chemical Engineering — firsthand Dagang atmospheric/vacuum modelling and planning references; profile publication date unknown","checkedAt":"2026-11-11"},{"url":"https://www.pacifpetrol.com/es/departamentos","name":"Pacifpetrol — natural-gasoline plant and separately described Casa Bomba crude handling","checkedAt":"2026-11-11"},{"url":"https://bibdigital.epn.edu.ec/bitstream/15000/133/1/CD-0539.pdf","name":"EPN — February 2007 Gustavo Galindo Velasco field contingency study; separate plant locations, Figure 2.1","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-29343421","name":"Wellficent Atlas — Stanic; independently reviewed process scope","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-478885591","name":"Wellficent Atlas — 中国石油大港石化分公司; independently reviewed process scope","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-1295964546","name":"Wellficent Atlas — Pacifpetrol; independently reviewed process scope","checkedAt":"2026-11-11"},{"url":"https://library.sprep.org/sites/default/files/PNG_Draft_NATPLAN_Mar07.pdf","name":"PNG National Marine Spill Contingency Plan — March 2007 copy hosted by SPREP; Mobil shore storage, Appendix 4 p.68","checkedAt":"2026-11-11"},{"url":"https://www.mobil-png.com/en-pg","name":"Mobil PNG — fuel distribution and national delivery scope; publication date unknown","checkedAt":"2026-11-11"},{"url":"https://www.pngports.com.pg/index.php/port-information/ports-of-png/lae-port","name":"PNG Ports — Lae port setting and fuel suppliers; port position is not a tank-farm survey","checkedAt":"2026-11-11"},{"url":"https://pumaenergy.com/wp-content/uploads/2023/05/Puma-Energy-Annual-Report-2020.pdf","name":"Puma Energy Annual Report 2020 — Lae terminals and solar-project scope, PDF p.38 / printed p.36","checkedAt":"2026-11-11"},{"url":"https://mortronix.com.pg/solar-power-systems/","name":"Mortronix — firsthand 2021 solar installations at Lae Aircorps and Speybank","checkedAt":"2026-11-11"},{"url":"https://news.cnpc.com.cn/system/2024/11/21/030148219.shtml","name":"CNPC — firsthand Changqing production-manager discussion, visible date 21 November 2024","checkedAt":"2026-11-11","publishedAt":"2024-11-21"},{"url":"https://news.cnpc.com.cn/system/2025/01/06/030151948.shtml","name":"CNPC — firsthand Changqing product-planning discussion, visible date 25 December 2024 despite the 2025/01/06 path","checkedAt":"2026-11-11","publishedAt":"2024-12-25"},{"url":"https://wellficent.com/en/refineries/osm-way-673249516","name":"Wellficent Atlas — Mobil PNG Ltd; independently reviewed process scope","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-676955523","name":"Wellficent Atlas — Puma Energy PNG Ltd; independently reviewed process scope","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-292039956","name":"Wellficent Atlas — 长庆石化; independently reviewed process scope","checkedAt":"2026-11-11"}],"translations":{"en":"https://wellficent.com/en/news/refinery-terminal-status-permit-data-engineering-guide","tr":"https://wellficent.com/tr/news/refinery-terminal-status-permit-data-engineering-guide","ar":"https://wellficent.com/ar/news/refinery-terminal-status-permit-data-engineering-guide","fr":"https://wellficent.com/fr/news/refinery-terminal-status-permit-data-engineering-guide","es":"https://wellficent.com/es/news/refinery-terminal-status-permit-data-engineering-guide","ru":"https://wellficent.com/ru/news/refinery-terminal-status-permit-data-engineering-guide","pt":"https://wellficent.com/pt/news/refinery-terminal-status-permit-data-engineering-guide"},"corrections":[{"at":"2026-11-11T17:12:55Z","language":"en","text":"Add verified edible-oil and gold-copper processing examples, dated Aruba closure policy and historical Isla process evidence with direct Atlas references and related engineering readings; preserve earlier text, calculations, image, correction history and first publication."},{"at":"2026-11-11T18:12:23Z","language":"en","text":"Added primary-source examples distinguishing Persian Gulf Star condensate feed, Somerset conversion, the individually located DE.CO terminal and historical Kirishi refining. Preserved all previous text, calculations, image, correction history and first publication; no current operation or crude-capacity inference."},{"at":"2026-11-11T19:18:10Z","language":"en","text":"Added independently reviewed Bari and Dagang historical crude-process evidence and Ancon natural-gasoline recovery, with source-period, remediation-area and map-CRS limits. Preserved prior text, calculations, illustration, corrections and first publication; no current operating or capacity inference."},{"at":"2026-11-11T20:20:02Z","language":"en","text":"Added primary-source Lae terminal and Changqing process cases, distinguishing solar-project status, national delivery flows and visible publication dates from site operation, crude capacity and URL dates. All prior text, calculations, illustration, corrections and first publication remain."}],"locations":[],"type":"analysis","analysis":{"asOf":"2026-11-11","kind":"technical-economic","chart":{"kind":"illustrative","note":{"ar":"سيناريوهات حسابية: τ = 24000 / Q، حيث Q = 3000 أو 6000 أو 12000 bbl/day على أساس حجم سائل متوافق. المخزون المتاح والشحن الثابت مفترضان؛ ليست بيانات منشأة مقاسة أو توقع نفاد أو طاقة تقطير خام.","en":"Calculated scenarios: τ = 24000 / Q, with Q = 3000, 6000 or 12000 bbl/day on a compatible liquid-volume basis. Assumed usable stock and constant dispatch; no measured facility data, stockout forecast or crude-distillation capacity.","es":"Escenarios calculados: τ = 24000 / Q; Q = 3000, 6000 o 12000 bbl/día sobre una referencia de volumen líquido compatible. Inventario utilizable y despacho constante supuestos; no son mediciones, pronósticos de agotamiento ni capacidad de destilación.","fr":"Scénarios calculés : τ = 24000 / Q, avec Q = 3000, 6000 ou 12000 bbl/jour sur une base de volume liquide compatible. Stock utilisable et expédition constante supposés ; ni mesures de site, ni prévision de rupture, ni capacité de distillation.","pt":"Cenários calculados: τ = 24000 / Q; Q = 3000, 6000 ou 12000 bbl/dia numa base de volume líquido compatível. Inventário utilizável e expedição constante supostos; não são medições, previsões de rutura nem capacidade de destilação.","ru":"Расчётные сценарии: τ = 24000 / Q, где Q = 3000, 6000 или 12000 bbl/сутки на совместимой базе объёма жидкости. Запас и постоянная отгрузка условные; это не измерения объекта, прогноз исчерпания или мощность перегонки.","tr":"Hesaplanan senaryolar: τ = 24000 / Q; Q = 3000, 6000 veya 12000 bbl/gün, uyumlu sıvı hacmi temelinde. Kullanılabilir stok ve sabit sevkiyat varsayımdır; gerçek tesis ölçümü, stok tükenme öngörüsü veya ham petrol damıtma kapasitesi değildir."},"rows":[{"label":{"ar":"3000 برميل/يوم","en":"3000 bbl/day","es":"3000 bbl/día","fr":"3000 bbl/jour","pt":"3000 bbl/dia","ru":"3000 bbl/сутки","tr":"3000 bbl/gün"},"value":8},{"label":{"ar":"6000 برميل/يوم","en":"6000 bbl/day","es":"6000 bbl/día","fr":"6000 bbl/jour","pt":"6000 bbl/dia","ru":"6000 bbl/сутки","tr":"6000 bbl/gün"},"value":4},{"label":{"ar":"12000 برميل/يوم","en":"12000 bbl/day","es":"12000 bbl/día","fr":"12000 bbl/jour","pt":"12000 bbl/dia","ru":"12000 bbl/сутки","tr":"12000 bbl/gün"},"value":2}],"unit":"days","title":{"ar":"تغطية مخزون افتراضي: 24,000 bbl قابلة للاستخدام","en":"Hypothetical inventory cover: 24,000 bbl usable stock","es":"Cobertura hipotética: 24.000 bbl utilizables","fr":"Couverture fictive : stock utilisable de 24 000 bbl","pt":"Cobertura hipotética: 24.000 bbl utilizáveis","ru":"Условное покрытие: доступный запас 24 000 bbl","tr":"Varsayımsal stok süresi: 24.000 bbl kullanılabilir stok"},"unitLabel":{"ar":"يوم","en":"days","es":"días","fr":"jours","pt":"dias","ru":"сутки","tr":"gün"}},"horizon":"Facility evidence and inventory arithmetic","horizonLabel":{"ar":"أدلة المنشآت وحساب المخزون","en":"Facility evidence and inventory arithmetic","es":"Pruebas de instalaciones y cálculo de inventario","fr":"Preuves sur les sites et calcul de stock","pt":"Provas sobre instalações e cálculo de inventário","ru":"Доказательства по объектам и расчёт запаса","tr":"Tesis kanıtı ve stok hesabı"},"evidenceCutoff":"2026-11-11"},"relatedArticles":[{"canonicalSlug":"refinery-capacity-calendar-stream-day-engineering-guide","url":"https://wellficent.com/en/news/refinery-capacity-calendar-stream-day-engineering-guide","title":"Refinery capacity: calendar day, stream day and actual throughput","language":"en"},{"canonicalSlug":"api-gravity-density-mass-volume-engineering-guide","url":"https://wellficent.com/en/news/api-gravity-density-mass-volume-engineering-guide","title":"API Gravity, Density and Mass–Volume Conversion: A Petroleum Engineering Guide","language":"en"},{"canonicalSlug":"drilling-hydrostatic-pressure-ecd-engineering-guide","url":"https://wellficent.com/en/news/drilling-hydrostatic-pressure-ecd-engineering-guide","title":"Drilling pressure: hydrostatics, ECD and the mud window","language":"en"},{"canonicalSlug":"refinery-heat-duty-fuel-efficiency-energy-intensity-engineering-guide","url":"https://wellficent.com/en/news/refinery-heat-duty-fuel-efficiency-energy-intensity-engineering-guide","title":"Refinery Heat Duty, Fuel Efficiency and Energy Intensity: An Engineering Guide","language":"en"},{"canonicalSlug":"refinery-mass-balance-processing-gain-engineering-guide","url":"https://wellficent.com/en/news/refinery-mass-balance-processing-gain-engineering-guide","title":"Refinery Mass Balance and Processing Gain: Why More Volume Does Not Mean More Mass","language":"en"}],"image":{"url":"https://wellficent.com/media/eb8cb1303daf610f3fb31dd2c4e70462855119c8df80db825c09ba5b85ac65ff.webp","width":1536,"height":1024,"alt":"Conceptual products terminal with three tanks inside containment, a pump skid and a separate tanker-loading canopy; not a named facility.","credit":"Wellficent / Codex imagegen — AI-generated conceptual illustration; not an authentic project photograph, site survey or process schematic.","licenseUrl":"https://openai.com/policies/terms-of-use/"}}},{"requestedLanguage":"en","fallback":false,"record":{"id":"api-gravity-density-mass-volume-engineering-guide","canonicalSlug":"api-gravity-density-mass-volume-engineering-guide","url":"https://wellficent.com/en/news/api-gravity-density-mass-volume-engineering-guide","language":"en","title":"API Gravity, Density and Mass–Volume Conversion: A Petroleum Engineering Guide","summary":"Verified EIA and NIST definitions, reproducible barrel-to-tonne calculations and a blending example explain why petroleum density conversions need a declared reference basis.","body":["A barrel measures volume; a tonne measures mass. Moving between them requires the density of the actual liquid on compatible temperature and pressure bases. API gravity offers a familiar petroleum reporting scale, but a quoted API value alone does not turn an operating tank volume, refinery capacity or well observation into a comparable mass measurement.","This guide uses the U.S. Energy Information Administration’s API definition and a published NIST gravimetric-meter example. Its three oil samples, parcel and blend are hypothetical engineering inputs, not reported field data. Calculations retain unrounded intermediate values. The illustration is conceptual, and the chart shows arithmetic derived from the stated inputs rather than a measured assay or forecast."],"keyPoints":[],"sections":[{"heading":"Start with the reference conditions","paragraphs":["EIA defines API gravity through the specific gravity of petroleum at 60 °F relative to water at 60 °F. Specific gravity, SG, is a dimensionless density ratio. The two temperatures matter: 60 °F is approximately 15.56 °C, and an observed density at another temperature is not automatically the same reference quantity. A laboratory report should identify the sample, method, temperature and reporting basis.","Keep the fluid definition with the number. Crude oil, condensate, a refined product and drilling mud are different materials even when their reported density ratios happen to resemble each other. The examples below concern a single petroleum liquid at the stated reference condition. They do not provide a generic correction for water, suspended solids, entrained gas or changing phase composition."]},{"heading":"Convert API gravity to specific gravity","paragraphs":["The EIA relationship is °API = 141.5 / SG − 131.5. Rearrangement gives SG = 141.5 / (°API + 131.5). Thus higher API gravity means lower reference specific gravity. Water on this relative-density basis has SG = 1 and therefore 10 °API. The formula defines a reporting scale; it does not supply an oil composition or a viscosity.","For the hypothetical 35 °API sample, SG = 141.5 / 166.5 = 0.84984985 after rounding. The 20 and 50 °API samples give 0.93399340 and 0.77961433 respectively. Substituting these unrounded results back into the API equation recovers the inputs. Rounding to 0.85 early may be adequate for a quick estimate but should not replace the original value in a reproducible calculation."]},{"heading":"Turn the ratio into a density with units","paragraphs":["NIST’s August 2005 article on gravimetric testing of oil meters gives density at 60 °F in pounds per U.S. gallon as SG × 8.337193. Its published 28.3 °API example gives approximately 7.38 lb/US gal, which our calculation reproduces. This is a historical technical reference for the conversion relationship, not a claim that the article replaces current metering requirements.","Using the same coefficient, the 35 °API sample gives 7.08536222 lb/US gal. One petroleum barrel contains 42 U.S. gallons, one avoirdupois pound equals 0.45359237 kg, and one metric tonne is 1,000 kg. EIA and NIST list approximately 0.1589873 m³ per petroleum barrel. Keeping the U.S. gallon explicit avoids substituting the different Imperial gallon.","The illustrative mass equation is m[t] = V[bbl] × 42 × SG × 8.337193 × 0.45359237 / 1000. Dividing the mass per barrel in kilograms by the rounded volume factor gives approximately 849.01 kg/m³ for the 35 °API sample. The displayed SI density is consequently approximate. Retaining extra calculation digits improves reproducibility; it does not create extra precision in the source coefficient or sample measurement."]},{"heading":"Calculate a parcel and compare the three cases","paragraphs":["Assume a hypothetical 100,000 bbl parcel with its volume already expressed at 60 °F and with a compatible pressure basis. For 35 °API, the equation gives 13,498.24 t after rounding. The reciprocal factor is approximately 7.4084 bbl/t. A generic barrels-per-tonne factor would lose the dependence on liquid density. Applying the factor to a volume measured at an uncorrected tank temperature would introduce a different, unresolved problem.","Holding the reference volume at 100,000 bbl, the 20 °API case gives 14,834.70 t and the 50 °API case gives 12,382.68 t. The accompanying chart compares those calculated masses. This is an isolated density comparison: it does not measure refinery throughput, product yield, crude quality beyond density, or a change in physical production. A daily volume would require its own time denominator before being reported as a mass rate."]},{"heading":"Blend density before converting back to API","paragraphs":["Consider a second hypothetical calculation: equal reference volumes of the 20 and 50 °API liquids, with volumes assumed additive and no material loss. Average the specific gravities under those assumptions: SGblend = (0.93399340 + 0.77961433) / 2 = 0.85680386. Applying the API formula to the unrounded mean gives 33.64865 °API, or about 33.65 °API.","Averaging the two API numbers directly gives 35 °API, a different answer because the API transformation is nonlinear. The equal-volume assumption is essential; equal masses need a different volume calculation. Real mixtures can also depart from volume additivity. For an actual transfer or blend, use the relevant measured mixture properties and applicable correction method rather than treating this teaching example as a certified blend prediction."]},{"heading":"Separate numerical sensitivity from measurement uncertainty","paragraphs":["For fixed reference volume and coefficient, mass is proportional to 1 / (°API + 131.5). A first-order relative sensitivity is therefore Δm/m ≈ −ΔAPI / (°API + 131.5). Around 35 °API, a hypothetical ±0.5 °API change corresponds to approximately ±0.3003% mass change when all other inputs remain fixed.","That result is a local sensitivity, not a confidence interval or an instrument accuracy claim. A measurement uncertainty budget must also consider the volume measurement, sampling, temperature determination, calibration and any dependence between inputs. NIST’s meter-testing discussion explains why product data sheets can require assumptions about successive batches. More decimal places in an API-to-SG conversion do not remove those assumptions."]},{"heading":"Keep engineering calculations separate from dataset observations","paragraphs":["An annual refinery rating in tonnes cannot be converted into barrels per day responsibly without an appropriate density and time basis. Even a correct mass–volume conversion leaves calendar-day capacity, stream-day capacity and actual annual throughput as different quantities. The related refinery-capacity guide explains those denominators. These hypothetical densities are not new capacity values for any Refinery Atlas record.","The same discipline applies to wells. A drilling-fluid density used in hydrostatic-pressure calculations is not a measurement of produced-oil API gravity. A source field’s label, fluid and reference conditions must survive any reuse. Linking technical reading does not establish that two records describe the same physical well, that a field supplies a refinery, or that an unreported fluid property is known."]},{"heading":"A reproducible workflow and its limits","paragraphs":["Record the original API value and its reference basis; calculate SG without early rounding; apply the explicitly chosen density coefficient; carry units through the barrel, gallon, pound and tonne conversions; and round only the displayed result. A reverse calculation should recover the original API value and parcel volume within the stated rounding. Preserve both source references and the calculation assumptions when sharing the result.","For a real engineering application, establish whether the measured volume and density refer to the same sample, phase and conditions. Obtain appropriate temperature or pressure corrections when they do not. API gravity alone supplies neither those corrections nor a complete crude assay. The examples here are reproducible definitions and arithmetic reviewed on 11 November 2026; they are not operating instructions, a metering certification or a production forecast."]}],"text":"API Gravity, Density and Mass–Volume Conversion: A Petroleum Engineering Guide\n\nVerified EIA and NIST definitions, reproducible barrel-to-tonne calculations and a blending example explain why petroleum density conversions need a declared reference basis.\n\nA barrel measures volume; a tonne measures mass. Moving between them requires the density of the actual liquid on compatible temperature and pressure bases. API gravity offers a familiar petroleum reporting scale, but a quoted API value alone does not turn an operating tank volume, refinery capacity or well observation into a comparable mass measurement.\n\nThis guide uses the U.S. Energy Information Administration’s API definition and a published NIST gravimetric-meter example. Its three oil samples, parcel and blend are hypothetical engineering inputs, not reported field data. Calculations retain unrounded intermediate values. The illustration is conceptual, and the chart shows arithmetic derived from the stated inputs rather than a measured assay or forecast.\n\nStart with the reference conditions\n\nEIA defines API gravity through the specific gravity of petroleum at 60 °F relative to water at 60 °F. Specific gravity, SG, is a dimensionless density ratio. The two temperatures matter: 60 °F is approximately 15.56 °C, and an observed density at another temperature is not automatically the same reference quantity. A laboratory report should identify the sample, method, temperature and reporting basis.\n\nKeep the fluid definition with the number. Crude oil, condensate, a refined product and drilling mud are different materials even when their reported density ratios happen to resemble each other. The examples below concern a single petroleum liquid at the stated reference condition. They do not provide a generic correction for water, suspended solids, entrained gas or changing phase composition.\n\nConvert API gravity to specific gravity\n\nThe EIA relationship is °API = 141.5 / SG − 131.5. Rearrangement gives SG = 141.5 / (°API + 131.5). Thus higher API gravity means lower reference specific gravity. Water on this relative-density basis has SG = 1 and therefore 10 °API. The formula defines a reporting scale; it does not supply an oil composition or a viscosity.\n\nFor the hypothetical 35 °API sample, SG = 141.5 / 166.5 = 0.84984985 after rounding. The 20 and 50 °API samples give 0.93399340 and 0.77961433 respectively. Substituting these unrounded results back into the API equation recovers the inputs. Rounding to 0.85 early may be adequate for a quick estimate but should not replace the original value in a reproducible calculation.\n\nTurn the ratio into a density with units\n\nNIST’s August 2005 article on gravimetric testing of oil meters gives density at 60 °F in pounds per U.S. gallon as SG × 8.337193. Its published 28.3 °API example gives approximately 7.38 lb/US gal, which our calculation reproduces. This is a historical technical reference for the conversion relationship, not a claim that the article replaces current metering requirements.\n\nUsing the same coefficient, the 35 °API sample gives 7.08536222 lb/US gal. One petroleum barrel contains 42 U.S. gallons, one avoirdupois pound equals 0.45359237 kg, and one metric tonne is 1,000 kg. EIA and NIST list approximately 0.1589873 m³ per petroleum barrel. Keeping the U.S. gallon explicit avoids substituting the different Imperial gallon.\n\nThe illustrative mass equation is m[t] = V[bbl] × 42 × SG × 8.337193 × 0.45359237 / 1000. Dividing the mass per barrel in kilograms by the rounded volume factor gives approximately 849.01 kg/m³ for the 35 °API sample. The displayed SI density is consequently approximate. Retaining extra calculation digits improves reproducibility; it does not create extra precision in the source coefficient or sample measurement.\n\nCalculate a parcel and compare the three cases\n\nAssume a hypothetical 100,000 bbl parcel with its volume already expressed at 60 °F and with a compatible pressure basis. For 35 °API, the equation gives 13,498.24 t after rounding. The reciprocal factor is approximately 7.4084 bbl/t. A generic barrels-per-tonne factor would lose the dependence on liquid density. Applying the factor to a volume measured at an uncorrected tank temperature would introduce a different, unresolved problem.\n\nHolding the reference volume at 100,000 bbl, the 20 °API case gives 14,834.70 t and the 50 °API case gives 12,382.68 t. The accompanying chart compares those calculated masses. This is an isolated density comparison: it does not measure refinery throughput, product yield, crude quality beyond density, or a change in physical production. A daily volume would require its own time denominator before being reported as a mass rate.\n\nBlend density before converting back to API\n\nConsider a second hypothetical calculation: equal reference volumes of the 20 and 50 °API liquids, with volumes assumed additive and no material loss. Average the specific gravities under those assumptions: SGblend = (0.93399340 + 0.77961433) / 2 = 0.85680386. Applying the API formula to the unrounded mean gives 33.64865 °API, or about 33.65 °API.\n\nAveraging the two API numbers directly gives 35 °API, a different answer because the API transformation is nonlinear. The equal-volume assumption is essential; equal masses need a different volume calculation. Real mixtures can also depart from volume additivity. For an actual transfer or blend, use the relevant measured mixture properties and applicable correction method rather than treating this teaching example as a certified blend prediction.\n\nSeparate numerical sensitivity from measurement uncertainty\n\nFor fixed reference volume and coefficient, mass is proportional to 1 / (°API + 131.5). A first-order relative sensitivity is therefore Δm/m ≈ −ΔAPI / (°API + 131.5). Around 35 °API, a hypothetical ±0.5 °API change corresponds to approximately ±0.3003% mass change when all other inputs remain fixed.\n\nThat result is a local sensitivity, not a confidence interval or an instrument accuracy claim. A measurement uncertainty budget must also consider the volume measurement, sampling, temperature determination, calibration and any dependence between inputs. NIST’s meter-testing discussion explains why product data sheets can require assumptions about successive batches. More decimal places in an API-to-SG conversion do not remove those assumptions.\n\nKeep engineering calculations separate from dataset observations\n\nAn annual refinery rating in tonnes cannot be converted into barrels per day responsibly without an appropriate density and time basis. Even a correct mass–volume conversion leaves calendar-day capacity, stream-day capacity and actual annual throughput as different quantities. The related refinery-capacity guide explains those denominators. These hypothetical densities are not new capacity values for any Refinery Atlas record.\n\nThe same discipline applies to wells. A drilling-fluid density used in hydrostatic-pressure calculations is not a measurement of produced-oil API gravity. A source field’s label, fluid and reference conditions must survive any reuse. Linking technical reading does not establish that two records describe the same physical well, that a field supplies a refinery, or that an unreported fluid property is known.\n\nA reproducible workflow and its limits\n\nRecord the original API value and its reference basis; calculate SG without early rounding; apply the explicitly chosen density coefficient; carry units through the barrel, gallon, pound and tonne conversions; and round only the displayed result. A reverse calculation should recover the original API value and parcel volume within the stated rounding. Preserve both source references and the calculation assumptions when sharing the result.\n\nFor a real engineering application, establish whether the measured volume and density refer to the same sample, phase and conditions. Obtain appropriate temperature or pressure corrections when they do not. API gravity alone supplies neither those corrections nor a complete crude assay. The examples here are reproducible definitions and arithmetic reviewed on 11 November 2026; they are not operating instructions, a metering certification or a production forecast.\n\nTechnical and economic analysis\n\nAnalysis as of: 2026-11-11\n\nEvidence cutoff: 2026-11-11\n\nOutlook horizon: Reference-property calculations\n\nIllustrative sensitivity\n\nCalculated mass of a hypothetical 100,000 bbl parcel at 60 °F\n\nHypothetical single-liquid inputs at 60 °F on a compatible pressure basis: m[t] = 100000 × 42 × SG × 8.337193 × 0.45359237 / 1000; SG = 141.5 / (API + 131.5). Calculated comparison, not measurements or a forecast.\n\nThese calculations illustrate stated assumptions; they are not observations or a calibrated forecast.\n\n20 °API: 14,834.6974 metric tonnes\n\n35 °API: 13,498.2382 metric tonnes\n\n50 °API: 12,382.6813 metric tonnes","category":"energy","region":"world","topics":["oil","gas"],"eventDate":"2026-11-11","eventDateBasis":"analysis-as-of-date","publishedAt":"2026-11-11T09:58:09Z","modifiedAt":"2026-11-11T09:58:09Z","publicationBasis":"first-publication","preparedAt":"2026-11-11T09:52:44Z","sourcePublishedAt":null,"translatedAt":null,"sources":[{"url":"https://www.eia.gov/tools/glossary/index.php?id=API","name":"EIA — API gravity definition","checkedAt":"2026-11-11"},{"url":"https://www.eia.gov/dnav/pet/tbldefs/pet_pnp_crq_tbldef2.asp","name":"EIA — Crude oil input qualities: API gravity reference basis","checkedAt":"2026-11-11"},{"url":"https://www.nist.gov/system/files/documents/2017/05/09/B-013.pdf","name":"NIST — Gravimetric Testing of Oil Meters: Converting Net Weight to Corrected Volume, August 2005","checkedAt":"2026-11-11"},{"url":"https://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9","name":"NIST — SI Guide Appendix B.9 conversion factors","checkedAt":"2026-11-11"},{"url":"https://www.eia.gov/totalenergy/conversion/factors/","name":"EIA — Energy conversion factors","checkedAt":"2026-11-11"},{"url":"https://www.osha.gov/otm/section-10-miscellaneous/chapter-1","name":"OSHA — Metric System Conversion, Tables X:1-8 and X:1-9","checkedAt":"2026-11-11"}],"translations":{"en":"https://wellficent.com/en/news/api-gravity-density-mass-volume-engineering-guide","tr":"https://wellficent.com/tr/news/api-gravity-density-mass-volume-engineering-guide","ar":"https://wellficent.com/ar/news/api-gravity-density-mass-volume-engineering-guide","fr":"https://wellficent.com/fr/news/api-gravity-density-mass-volume-engineering-guide","es":"https://wellficent.com/es/news/api-gravity-density-mass-volume-engineering-guide","ru":"https://wellficent.com/ru/news/api-gravity-density-mass-volume-engineering-guide","pt":"https://wellficent.com/pt/news/api-gravity-density-mass-volume-engineering-guide"},"corrections":[],"locations":[],"type":"analysis","analysis":{"asOf":"2026-11-11","kind":"technical-economic","chart":{"kind":"illustrative","note":{"ar":"مدخلات افتراضية لسائل واحد عند 60 °F وعلى أساس ضغط متوافق: m[t] = 100000 × 42 × SG × 8.337193 × 0.45359237 / 1000; SG = 141.5 / (API + 131.5). مقارنة حسابية وليست قياسات أو توقعاً.","en":"Hypothetical single-liquid inputs at 60 °F on a compatible pressure basis: m[t] = 100000 × 42 × SG × 8.337193 × 0.45359237 / 1000; SG = 141.5 / (API + 131.5). Calculated comparison, not measurements or a forecast.","es":"Líquidos hipotéticos a 60 °F con una base de presión compatible: m[t] = 100000 × 42 × SG × 8.337193 × 0.45359237 / 1000; SG = 141.5 / (API + 131.5). Comparación calculada, no mediciones ni pronóstico.","fr":"Liquides fictifs à 60 °F et sur une base de pression compatible : m[t] = 100000 × 42 × SG × 8.337193 × 0.45359237 / 1000; SG = 141.5 / (API + 131.5). Comparaison calculée, ni mesures ni prévision.","pt":"Líquidos hipotéticos a 60 °F numa base de pressão compatível: m[t] = 100000 × 42 × SG × 8.337193 × 0.45359237 / 1000; SG = 141.5 / (API + 131.5). Comparação calculada, não medições nem previsão.","ru":"Условные однофазные жидкости при 60 °F и совместимой базе давления: m[t] = 100000 × 42 × SG × 8.337193 × 0.45359237 / 1000; SG = 141.5 / (API + 131.5). Расчётное сравнение, не измерения и не прогноз.","tr":"Uyumlu basınç temelinde 60 °F’de varsayımsal tek sıvı girdileri: m[t] = 100000 × 42 × SG × 8.337193 × 0.45359237 / 1000; SG = 141.5 / (API + 131.5). Hesaplanan karşılaştırmadır; ölçüm veya öngörü değildir."},"rows":[{"label":{"ar":"20 °API","en":"20 °API","es":"20 °API","fr":"20 °API","pt":"20 °API","ru":"20 °API","tr":"20 °API"},"value":14834.697442626712},{"label":{"ar":"35 °API","en":"35 °API","es":"35 °API","fr":"35 °API","pt":"35 °API","ru":"35 °API","tr":"35 °API"},"value":13498.238213561242},{"label":{"ar":"50 °API","en":"50 °API","es":"50 °API","fr":"50 °API","pt":"50 °API","ru":"50 °API","tr":"50 °API"},"value":12382.68133640742}],"unit":"metric tonnes","title":{"ar":"الكتلة المحسوبة لشحنة افتراضية حجمها 100,000 bbl عند 60 °F","en":"Calculated mass of a hypothetical 100,000 bbl parcel at 60 °F","es":"Masa calculada de un lote hipotético de 100.000 bbl a 60 °F","fr":"Masse calculée d’un lot fictif de 100 000 bbl à 60 °F","pt":"Massa calculada de um lote hipotético de 100.000 bbl a 60 °F","ru":"Расчётная масса условной партии 100 000 баррелей при 60 °F","tr":"60 °F’de varsayımsal 100.000 bbl yükün hesaplanan kütlesi"},"unitLabel":{"ar":"طن متري","en":"metric tonnes","es":"toneladas métricas","fr":"tonnes métriques","pt":"toneladas métricas","ru":"метрические тонны","tr":"metrik ton"}},"horizon":"Reference-property calculations","horizonLabel":{"ar":"حسابات الخواص المرجعية","en":"Reference-property calculations","es":"Cálculos de propiedades de referencia","fr":"Calculs des propriétés de référence","pt":"Cálculos de propriedades de referência","ru":"Расчёты свойств при опорных условиях","tr":"Referans özellik hesapları"},"evidenceCutoff":"2026-11-11"},"relatedArticles":[{"canonicalSlug":"refinery-capacity-calendar-stream-day-engineering-guide","url":"https://wellficent.com/en/news/refinery-capacity-calendar-stream-day-engineering-guide","title":"Refinery capacity: calendar day, stream day and actual throughput","language":"en"},{"canonicalSlug":"oil-gas-production-data-rates-boe-decline-engineering-guide","url":"https://wellficent.com/en/news/oil-gas-production-data-rates-boe-decline-engineering-guide","title":"Oil and gas production data: rates, boe, decline and value","language":"en"},{"canonicalSlug":"drilling-hydrostatic-pressure-ecd-engineering-guide","url":"https://wellficent.com/en/news/drilling-hydrostatic-pressure-ecd-engineering-guide","title":"Drilling pressure: hydrostatics, ECD and the mud window","language":"en"}],"image":{"url":"https://wellficent.com/media/24a505a86fabe496d39553ced55e101debf3f8633fd736541d10eb0f43cbb2d1.webp","width":1536,"height":1024,"alt":"Conceptual petroleum laboratory illustration: a floating hydrometer in an amber liquid sample, a closed bottle and a balance; no measured values are shown.","credit":"Wellficent / Codex imagegen — AI-generated conceptual illustration; not an authentic project photograph or evidence of measured sample properties.","licenseUrl":"https://openai.com/policies/terms-of-use/"}}},{"requestedLanguage":"en","fallback":false,"record":{"id":"drilling-hydrostatic-pressure-ecd-engineering-guide","canonicalSlug":"drilling-hydrostatic-pressure-ecd-engineering-guide","url":"https://wellficent.com/en/news/drilling-hydrostatic-pressure-ecd-engineering-guide","language":"en","title":"Drilling pressure: hydrostatics, ECD and the mud window","summary":"Reproducible petroleum-engineering examples explain hydrostatic pressure, annular friction and equivalent circulating density, with a verified Well Atlas reference.","body":["A drilling-fluid density is only one part of a pressure statement. The pressure acting on an exposed formation also depends on vertical fluid height, the pressure at the top of the column and, during circulation, the hydraulic losses along the return path. Reading a mud-weight number as the complete bottomhole condition can hide the effect of stopping pumps, changing flow or moving pipe.","This research guide separates physical definitions, fictional calculations and a retained public well record. Every pressure-window value below is an invented teaching input, clearly labelled as such. None describes the pressure, mud programme or fracture limit of SODIR wellbore 16/11-1 S. The purpose is to make an engineering argument reproducible before treating it as evidence about a real asset."],"keyPoints":["Hydrostatic pressure uses true vertical fluid height; circulation adds the annular pressure loss above the depth of interest.","In the fictional case, 12 ppg at 10,000 ft TVD gives 6,240 psi. Adding 520 psi annular friction gives 6,760 psi and 13 ppg ECD.","An atlas depth, a surface pump pressure and an illustrative mud window are different evidence objects; none substitutes for a measured downhole pressure profile."],"sections":[{"heading":"1. State the pressure reference and the fluid column","paragraphs":["For a static fluid of uniform density, the pressure increment is Δp = ρ × g × H. Density ρ in kg/m³, gravitational acceleration g in m/s² and vertical height H in metres give pressure in pascals. The pressure at the bottom also includes the pressure at the top. A gauge-pressure example with zero surface gauge pressure must not be silently relabelled as absolute pressure.","A single density represents a simplifying assumption. Temperature, compressibility, gas, multiple fluid layers and density variations can require integration over the actual vertical column. Measured depth follows the borehole and is useful for other calculations; it does not replace H in the gravity term. Equal units do not make those two depth quantities equivalent."]},{"heading":"2. Reproduce the static oilfield calculation","paragraphs":["Using the conventional rounded oilfield coefficient, hydrostatic increment in psi = 0.052 × mud weight in pounds per US gallon, ppg, × TVD in feet. For the fictional inputs 12 ppg and 10,000 ft TVD, multiplication gives 6,240 psi. This is an educational approximation with an explicit unit system, not a reported pressure test.","If a 15,000 ft measured depth is mistakenly used instead, the result becomes 9,360 psi. The excess is 3,120 psi, or 50% of the correct teaching result. This arithmetic isolates a depth-reference error while holding every other input constant. It does not quantify the uncertainty of an actual well, where the fluid density and pressure boundary may also be uncertain."]},{"heading":"3. Add the correct circulating-pressure component","paragraphs":["For this simplified steady forward-circulation case with zero surface backpressure, bottomhole gauge pressure equals the static annular hydrostatic pressure plus the annular friction loss between the depth of interest and the surface. SLB defines equivalent circulating density using that annular contribution; IADC separately defines annular pressure loss. The relevant path must therefore be identified before choosing a pressure value.","Assign a fictional annular loss of 520 psi. The bottomhole result is 6,240 + 520 = 6,760 psi. Standpipe pressure is not automatically this 520 psi: it also reflects other pressure losses in the circulating system, including the drillstring and bit. Substituting a total surface pump-pressure reading without separating the annular component changes the physical meaning of the calculation."]},{"heading":"4. Convert pressure to equivalent circulating density","paragraphs":["In the same units, ECD = mud weight + Δp_annulus / (0.052 × TVD). The example gives 12 + 520 / (0.052 × 10,000) = 13 ppg. ECD expresses a pressure as an equivalent uniform fluid density at the chosen depth; it does not mean the sampled mud in a tank has physically become 13 ppg.","If the assumed annular loss doubles to 1,040 psi while density and TVD stay fixed, ECD becomes 14 ppg and bottomhole pressure becomes 7,280 psi. This is a sensitivity calculation, not a prediction that doubling flow doubles pressure loss. A hydraulic model needs rheology, geometry, flow regime, cuttings loading and other inputs before relating pump rate to friction."]},{"heading":"5. Test a fictional pressure window","paragraphs":["Assume a pore-pressure equivalent of 11.5 ppg and a fracture-pressure equivalent of 13.5 ppg at the same 10,000 ft TVD and with the same pressure reference. Their teaching pressure equivalents are 5,980 and 7,020 psi. The 12 ppg static column is 260 psi above the assumed pore pressure; the 13 ppg circulating case is 260 psi below the assumed upper boundary.","At 14 ppg ECD, the calculation exceeds that upper boundary by 260 psi. These are conditional comparisons, not a safe operating envelope or a prediction of losses. Real limits can vary along the entire open hole and at a casing shoe. Uncertainty, transients and operational margins must be considered separately; the weakest exposed interval need not be at total depth."]},{"heading":"6. Understand what changing conditions invalidate","paragraphs":["The chart holds mud weight and depth constant and varies only the assumed annular friction. It cannot predict surge or swab while moving pipe, gas expansion, a pump transition or a managed-pressure operation with surface backpressure. Removing the assumed friction term in a static calculation does not establish that every real transient has disappeared.","Using 15,000 ft MD in the ECD denominator would give about 12.67 ppg for the 520 psi case, understating the correct 13 ppg equivalent. This error has a different direction from the excessive hydrostatic pressure calculated with MD earlier. Checking each equation dimensionally and physically is more reliable than assuming a depth mistake always biases results in one direction."]},{"heading":"7. Connect to a documented Well Atlas record","paragraphs":["The existing Well Atlas record no-sodir-112 identifies SODIR wellbore 16/11-1 S, source record 112. Its retained measurements report 3,050 m MD and 3,020 m TVD, both referenced to RKB. These fields illustrate why source identity, depth type and reference travel together. The registry retains its 2 October 2026 source-check date; this article does not refresh that snapshot.","Neither depth is assigned to the fictional 10,000 ft pressure case. No mud density, annular loss, formation pressure or fracture test for that well is supplied by this guide. Follow the direct atlas record and the separate depth-reference analysis to inspect the published provenance. A reading link is editorial context, not a new well measurement or a physical refinery-supply relationship."]},{"heading":"8. Turn a calculation into a research audit trail","paragraphs":["A reproducible assessment records the fluid-density source, vertical datum, depth of interest, surface-pressure boundary, annular-loss method and observation time. Preserve the original units and distinguish a measured pressure from a fitted estimate or teaching assumption. The API glossary hosted by the Oklahoma Corporation Commission provides a second historical terminology reference; it is not presented as a current operating standard.","For investment or procurement research, the engineering implication is a question to investigate: whether the documented hydraulic constraints affect equipment specification, usable operating range or programme execution. This guide calculates no cost saving, rig-time reduction, return or incident probability. Those outcomes require asset-specific evidence and an explicit economic model. Unknown measurements remain unknown."]}],"text":"Drilling pressure: hydrostatics, ECD and the mud window\n\nReproducible petroleum-engineering examples explain hydrostatic pressure, annular friction and equivalent circulating density, with a verified Well Atlas reference.\n\nHydrostatic pressure uses true vertical fluid height; circulation adds the annular pressure loss above the depth of interest.\n\nIn the fictional case, 12 ppg at 10,000 ft TVD gives 6,240 psi. Adding 520 psi annular friction gives 6,760 psi and 13 ppg ECD.\n\nAn atlas depth, a surface pump pressure and an illustrative mud window are different evidence objects; none substitutes for a measured downhole pressure profile.\n\nA drilling-fluid density is only one part of a pressure statement. The pressure acting on an exposed formation also depends on vertical fluid height, the pressure at the top of the column and, during circulation, the hydraulic losses along the return path. Reading a mud-weight number as the complete bottomhole condition can hide the effect of stopping pumps, changing flow or moving pipe.\n\nThis research guide separates physical definitions, fictional calculations and a retained public well record. Every pressure-window value below is an invented teaching input, clearly labelled as such. None describes the pressure, mud programme or fracture limit of SODIR wellbore 16/11-1 S. The purpose is to make an engineering argument reproducible before treating it as evidence about a real asset.\n\n1. State the pressure reference and the fluid column\n\nFor a static fluid of uniform density, the pressure increment is Δp = ρ × g × H. Density ρ in kg/m³, gravitational acceleration g in m/s² and vertical height H in metres give pressure in pascals. The pressure at the bottom also includes the pressure at the top. A gauge-pressure example with zero surface gauge pressure must not be silently relabelled as absolute pressure.\n\nA single density represents a simplifying assumption. Temperature, compressibility, gas, multiple fluid layers and density variations can require integration over the actual vertical column. Measured depth follows the borehole and is useful for other calculations; it does not replace H in the gravity term. Equal units do not make those two depth quantities equivalent.\n\n2. Reproduce the static oilfield calculation\n\nUsing the conventional rounded oilfield coefficient, hydrostatic increment in psi = 0.052 × mud weight in pounds per US gallon, ppg, × TVD in feet. For the fictional inputs 12 ppg and 10,000 ft TVD, multiplication gives 6,240 psi. This is an educational approximation with an explicit unit system, not a reported pressure test.\n\nIf a 15,000 ft measured depth is mistakenly used instead, the result becomes 9,360 psi. The excess is 3,120 psi, or 50% of the correct teaching result. This arithmetic isolates a depth-reference error while holding every other input constant. It does not quantify the uncertainty of an actual well, where the fluid density and pressure boundary may also be uncertain.\n\n3. Add the correct circulating-pressure component\n\nFor this simplified steady forward-circulation case with zero surface backpressure, bottomhole gauge pressure equals the static annular hydrostatic pressure plus the annular friction loss between the depth of interest and the surface. SLB defines equivalent circulating density using that annular contribution; IADC separately defines annular pressure loss. The relevant path must therefore be identified before choosing a pressure value.\n\nAssign a fictional annular loss of 520 psi. The bottomhole result is 6,240 + 520 = 6,760 psi. Standpipe pressure is not automatically this 520 psi: it also reflects other pressure losses in the circulating system, including the drillstring and bit. Substituting a total surface pump-pressure reading without separating the annular component changes the physical meaning of the calculation.\n\n4. Convert pressure to equivalent circulating density\n\nIn the same units, ECD = mud weight + Δp_annulus / (0.052 × TVD). The example gives 12 + 520 / (0.052 × 10,000) = 13 ppg. ECD expresses a pressure as an equivalent uniform fluid density at the chosen depth; it does not mean the sampled mud in a tank has physically become 13 ppg.\n\nIf the assumed annular loss doubles to 1,040 psi while density and TVD stay fixed, ECD becomes 14 ppg and bottomhole pressure becomes 7,280 psi. This is a sensitivity calculation, not a prediction that doubling flow doubles pressure loss. A hydraulic model needs rheology, geometry, flow regime, cuttings loading and other inputs before relating pump rate to friction.\n\n5. Test a fictional pressure window\n\nAssume a pore-pressure equivalent of 11.5 ppg and a fracture-pressure equivalent of 13.5 ppg at the same 10,000 ft TVD and with the same pressure reference. Their teaching pressure equivalents are 5,980 and 7,020 psi. The 12 ppg static column is 260 psi above the assumed pore pressure; the 13 ppg circulating case is 260 psi below the assumed upper boundary.\n\nAt 14 ppg ECD, the calculation exceeds that upper boundary by 260 psi. These are conditional comparisons, not a safe operating envelope or a prediction of losses. Real limits can vary along the entire open hole and at a casing shoe. Uncertainty, transients and operational margins must be considered separately; the weakest exposed interval need not be at total depth.\n\n6. Understand what changing conditions invalidate\n\nThe chart holds mud weight and depth constant and varies only the assumed annular friction. It cannot predict surge or swab while moving pipe, gas expansion, a pump transition or a managed-pressure operation with surface backpressure. Removing the assumed friction term in a static calculation does not establish that every real transient has disappeared.\n\nUsing 15,000 ft MD in the ECD denominator would give about 12.67 ppg for the 520 psi case, understating the correct 13 ppg equivalent. This error has a different direction from the excessive hydrostatic pressure calculated with MD earlier. Checking each equation dimensionally and physically is more reliable than assuming a depth mistake always biases results in one direction.\n\n7. Connect to a documented Well Atlas record\n\nThe existing Well Atlas record no-sodir-112 identifies SODIR wellbore 16/11-1 S, source record 112. Its retained measurements report 3,050 m MD and 3,020 m TVD, both referenced to RKB. These fields illustrate why source identity, depth type and reference travel together. The registry retains its 2 October 2026 source-check date; this article does not refresh that snapshot.\n\nNeither depth is assigned to the fictional 10,000 ft pressure case. No mud density, annular loss, formation pressure or fracture test for that well is supplied by this guide. Follow the direct atlas record and the separate depth-reference analysis to inspect the published provenance. A reading link is editorial context, not a new well measurement or a physical refinery-supply relationship.\n\n8. Turn a calculation into a research audit trail\n\nA reproducible assessment records the fluid-density source, vertical datum, depth of interest, surface-pressure boundary, annular-loss method and observation time. Preserve the original units and distinguish a measured pressure from a fitted estimate or teaching assumption. The API glossary hosted by the Oklahoma Corporation Commission provides a second historical terminology reference; it is not presented as a current operating standard.\n\nFor investment or procurement research, the engineering implication is a question to investigate: whether the documented hydraulic constraints affect equipment specification, usable operating range or programme execution. This guide calculates no cost saving, rig-time reduction, return or incident probability. Those outcomes require asset-specific evidence and an explicit economic model. Unknown measurements remain unknown.\n\nTechnical and economic analysis\n\nAnalysis as of: 2026-11-10\n\nEvidence cutoff: 2026-11-10\n\nOutlook horizon: Illustrative steady-state drilling hydraulics\n\nIllustrative sensitivity\n\nFictional pressure equivalents at fixed depth\n\nFictional inputs: 12 ppg mud, 10,000 ft TVD, zero surface gauge pressure. ECD = 12 + annular loss / (0.052 × 10,000). Losses 0 / 520 / 1,040 psi give 12 / 13 / 14 ppg. Not observations, a hydraulic flow model or a safe operating window; not SODIR 112.\n\nThese calculations illustrate stated assumptions; they are not observations or a calibrated forecast.\n\nStatic: no circulating friction: 12 equivalent density in pounds per US gallon\n\nAssumed annular loss: 520 psi: 13 equivalent density in pounds per US gallon\n\nAssumed annular loss: 1,040 psi: 14 equivalent density in pounds per US gallon","category":"energy","region":"world","topics":["oil","gas"],"eventDate":"2026-11-10","eventDateBasis":"analysis-as-of-date","publishedAt":"2026-11-10T20:41:03Z","modifiedAt":"2026-11-10T21:08:14Z","publicationBasis":"first-publication","preparedAt":"2026-11-10T20:39:33Z","sourcePublishedAt":null,"translatedAt":null,"sources":[{"url":"https://glossary.slb.com/en/terms/e/equivalent_circulating_density","name":"SLB Energy Glossary — equivalent circulating density","checkedAt":"2026-11-10"},{"url":"https://iadc.org/wp-content/uploads/2017/08/WSP_Definitions_rev1.pdf","name":"IADC — WellSharp Definitions, Revision 1; historical terminology","checkedAt":"2026-11-10","publishedAt":"2017-07-24"},{"url":"https://oklahoma.gov/content/dam/ok/en/occ/documents/og/api-glossary.pdf","name":"Oklahoma Corporation Commission — hosted historical API glossary","checkedAt":"2026-11-10"},{"url":"https://wellficent.com/en/wells/record/no-sodir-112","name":"Wellficent Well Atlas — retained SODIR source record 112; internal reference","checkedAt":"2026-11-10"}],"translations":{"en":"https://wellficent.com/en/news/drilling-hydrostatic-pressure-ecd-engineering-guide","tr":"https://wellficent.com/tr/news/drilling-hydrostatic-pressure-ecd-engineering-guide","ar":"https://wellficent.com/ar/news/drilling-hydrostatic-pressure-ecd-engineering-guide","fr":"https://wellficent.com/fr/news/drilling-hydrostatic-pressure-ecd-engineering-guide","es":"https://wellficent.com/es/news/drilling-hydrostatic-pressure-ecd-engineering-guide","ru":"https://wellficent.com/ru/news/drilling-hydrostatic-pressure-ecd-engineering-guide","pt":"https://wellficent.com/pt/news/drilling-hydrostatic-pressure-ecd-engineering-guide"},"corrections":[{"at":"2026-11-10T20:48:52Z","language":"en","text":"Improved Arabic display of formulas and Latin units with directional isolates. Calculations, assumptions, sources and first publication are unchanged."},{"at":"2026-11-10T21:08:14Z","language":"en","text":"Refined Arabic equation layout by defining MW explicitly and stating the chart calculation in words. Numerical values, physical meaning, sources and first publication are unchanged."}],"locations":[],"type":"analysis","analysis":{"asOf":"2026-11-10","kind":"technical-economic","chart":{"kind":"illustrative","note":{"ar":"مدخلات افتراضية: طين ⁦12 ppg⁩ وعمق ⁦10,000 ft TVD⁩ وضغط قياسي سطحي صفري. تُحسب ⁦ECD⁩ بإضافة ⁦12 ppg⁩ إلى حاصل قسمة الفقد الحلقي بوحدة ⁦psi⁩ على ⁦(0.052 × 10,000)⁩. الفواقد ⁦0 / 520 / 1,040 psi⁩ تعطي ⁦12 / 13 / 14 ppg⁩. ليست رصداً أو نموذج تدفق أو نافذة آمنة؛ وليست بيانات ⁦SODIR 112⁩.","en":"Fictional inputs: 12 ppg mud, 10,000 ft TVD, zero surface gauge pressure. ECD = 12 + annular loss / (0.052 × 10,000). Losses 0 / 520 / 1,040 psi give 12 / 13 / 14 ppg. Not observations, a hydraulic flow model or a safe operating window; not SODIR 112.","es":"Entradas ficticias: lodo de 12 ppg, 10.000 ft TVD, presión manométrica superficial cero. ECD = 12 + pérdida anular / (0,052 × 10.000). Pérdidas de 0 / 520 / 1.040 psi dan 12 / 13 / 14 ppg. No son observaciones, modelo de caudal ni ventana segura; no es SODIR 112.","fr":"Entrées fictives : boue 12 ppg, 10 000 ft TVD, pression manométrique de surface nulle. ECD = 12 + perte annulaire / (0,052 × 10 000). Les pertes 0 / 520 / 1 040 psi donnent 12 / 13 / 14 ppg. Ni observations, ni modèle de débit, ni fenêtre sûre ; pas SODIR 112.","pt":"Entradas fictícias: lama de 12 ppg, 10.000 ft TVD, pressão manométrica superficial zero. ECD = 12 + perda anular / (0,052 × 10.000). Perdas de 0 / 520 / 1.040 psi resultam em 12 / 13 / 14 ppg. Não são observações, modelo de vazão ou janela segura; não é SODIR 112.","ru":"Условные входные данные: раствор 12 ppg, 10 000 ft TVD, нулевое избыточное давление на поверхности. ECD = 12 + кольцевая потеря / (0,052 × 10 000). Потери 0 / 520 / 1 040 psi дают 12 / 13 / 14 ppg. Не наблюдения, модель расхода или безопасное окно; не SODIR 112.","tr":"Kurmaca girdiler: 12 ppg çamur, 10.000 ft TVD, sıfır yüzey gösterge basıncı. ECD = 12 + annüler kayıp / (0,052 × 10.000). 0 / 520 / 1.040 psi kayıplar 12 / 13 / 14 ppg verir. Gözlem, hidrolik debi modeli veya güvenli çalışma penceresi değildir; SODIR 112 değildir."},"rows":[{"label":{"ar":"ساكن: دون احتكاك دوران","en":"Static: no circulating friction","es":"Estático: sin fricción de circulación","fr":"Statique : sans frottement de circulation","pt":"Estático: sem atrito de circulação","ru":"Статика: без циркуляционного трения","tr":"Statik: dolaşım sürtünmesi yok"},"value":12},{"label":{"ar":"فقد حلقي مفترض: ⁦520 psi⁩","en":"Assumed annular loss: 520 psi","es":"Pérdida anular supuesta: 520 psi","fr":"Perte annulaire supposée : 520 psi","pt":"Perda anular suposta: 520 psi","ru":"Условная кольцевая потеря: 520 psi","tr":"Varsayılan annüler kayıp: 520 psi"},"value":13},{"label":{"ar":"فقد حلقي مفترض: ⁦1,040 psi⁩","en":"Assumed annular loss: 1,040 psi","es":"Pérdida anular supuesta: 1.040 psi","fr":"Perte annulaire supposée : 1 040 psi","pt":"Perda anular suposta: 1.040 psi","ru":"Условная кольцевая потеря: 1 040 psi","tr":"Varsayılan annüler kayıp: 1.040 psi"},"value":14}],"unit":"ppg","title":{"ar":"مكافئات ضغط افتراضية عند عمق ثابت","en":"Fictional pressure equivalents at fixed depth","es":"Equivalentes de presión ficticios a profundidad fija","fr":"Équivalents de pression fictifs à profondeur fixe","pt":"Equivalentes de pressão fictícios a profundidade fixa","ru":"Условные эквиваленты давления на одной глубине","tr":"Sabit derinlikte kurmaca basınç eşdeğerleri"},"unitLabel":{"ar":"الكثافة المكافئة بالرطل لكل غالون أمريكي","en":"equivalent density in pounds per US gallon","es":"densidad equivalente en libras por galón estadounidense","fr":"densité équivalente en livres par gallon américain","pt":"densidade equivalente em libras por galão dos EUA","ru":"эквивалентная плотность в фунтах на галлон США","tr":"ABD galonu başına pound cinsinden eşdeğer yoğunluk"}},"horizon":"Illustrative steady-state drilling hydraulics","horizonLabel":{"ar":"هيدروليكا حفر توضيحية في حالة مستقرة","en":"Illustrative steady-state drilling hydraulics","es":"Hidráulica de perforación estacionaria ilustrativa","fr":"Hydraulique de forage stationnaire illustrative","pt":"Hidráulica de perfuração permanente ilustrativa","ru":"Условная установившаяся гидравлика бурения","tr":"Örnek kararlı durum sondaj hidroliği"},"evidenceCutoff":"2026-11-10"},"relatedArticles":[{"canonicalSlug":"well-log-depth-md-tvd-datum-engineering-guide","url":"https://wellficent.com/en/news/well-log-depth-md-tvd-datum-engineering-guide","title":"Well-log depth: MD, TVD and datum explained","language":"en"},{"canonicalSlug":"oil-gas-production-data-rates-boe-decline-engineering-guide","url":"https://wellficent.com/en/news/oil-gas-production-data-rates-boe-decline-engineering-guide","title":"Oil and gas production data: rates, boe, decline and value","language":"en"}],"image":{"url":"https://wellficent.com/media/58395cb16fae5fe337bb27c2cb484c9bc05f0edb5102c3bb68335175bac8f69e.webp","width":1536,"height":1024,"alt":"AI-generated conceptual illustration of a fictional land drilling rig, mud-pump skids and fluid tanks; not a photograph of SODIR 112 or a validated equipment layout.","credit":"Wellficent — AI-generated conceptual editorial illustration, built-in imagegen, 10 November 2026. Fictional installation; not project photography or a validated engineering design. OpenAI terms apply; no blanket source-data licence is implied.","licenseUrl":"https://openai.com/policies/terms-of-use/"}}},{"requestedLanguage":"en","fallback":false,"record":{"id":"well-log-depth-md-tvd-datum-engineering-guide","canonicalSlug":"well-log-depth-md-tvd-datum-engineering-guide","url":"https://wellficent.com/en/news/well-log-depth-md-tvd-datum-engineering-guide","language":"en","title":"Well-log depth: MD, TVD and datum explained","summary":"A petroleum-engineering guide to depth references, well logs and hydrostatic pressure, with a verified SODIR example and reproducible calculations.","body":["A depth without its measurement path, reference and unit is an incomplete engineering statement. Three numbers can describe the same bottomhole position while answering different questions: how far the borehole travels, how far down it goes, and where it sits relative to sea level. Confusing those questions can distort a geological correlation, a pressure calculation or a drilling comparison even when every copied number is accurate.","This guide separates published observations from calculations and fictional teaching cases. The real example is Norwegian Offshore Directorate wellbore 16/11-1 S, source identifier 112, checked on 8 November 2026. The geometry and drilling-fluid cases are independent mathematical examples. They do not reconstruct that borehole, estimate its present pressure or prescribe an operating programme."],"keyPoints":["MD follows the borehole; TVD measures a vertical separation. A common unit does not make them interchangeable.","For SODIR 112, 3,050 m MD and 3,020 m TVD are reported from RKB. The 2,993 m depth below mean sea level is calculated using the reported 27 m RKB elevation.","Unknown datums, missing log samples and unavailable historical vintages remain unknown; they are not zero or observed measurements."],"sections":[{"heading":"1. Start with the coordinate, not the largest number","paragraphs":["Measured depth, MD, describes distance along a borehole. True vertical depth, TVD, describes the vertical separation from a stated reference. With the same starting point, a straight vertical hole has equal MD and TVD; a deviated path generally has a longer MD. A published total depth should therefore retain its depth type instead of being reduced to a generic depth field.","SLB’s terminology distinguishes these uses, while BOEM’s borehole field definitions explicitly reference total MD and TVD to the rig kelly bushing. That is evidence about those fields, not permission to assign the same reference to every other dataset. A comparable record needs the quantity, unit, zero point, sign convention and source identity together."]},{"heading":"2. A datum shift is a vertical calculation","paragraphs":["Define elevation as positive upward from mean sea level, MSL, and depth below MSL as positive downward. If the rotary kelly bushing, RKB, has elevation z_RKB, then depth_MSL = TVD_RKB − z_RKB. The subtraction changes the vertical reference; it does not convert MD into TVD. A different zero point or sign convention requires a separately stated transformation.","The historical UKOOA P7/2000 Revision 5 format distinguishes zero measured depth, zero true vertical depth and the permanent vertical datum. Its October 2002 terminology is a useful explanation of why a rig change or sidetrack can change the reference. It is not presented here as a new or mandatory reporting standard. Energistics’ WITSML 2.0 coordinate definition likewise carries datum and unit explicitly."]},{"heading":"3. Read one documented borehole carefully","paragraphs":["SODIR reports 16/11-1 S with total MD 3,050 m RKB, final TVD 3,020 m RKB, RKB elevation 27 m above MSL and water depth 67 m. These are source-reported values, not four measurements newly taken by Wellficent. The matching Well Atlas record is no-sodir-112: its sourceRecordId is 112 and its MD/TVD fields preserve the RKB reference. A text search also returns 7216/11-1 S, so a similar name alone is insufficient identification.","Under the sign convention above, the reported TVD gives 3,020 − 27 = 2,993 m below MSL. Subtracting the 67 m water depth gives a calculated 2,926 m vertical separation below the sea floor. Neither derived value replaces the source fields or constitutes an independent survey. In particular, subtracting 27 from the 3,050 m MD would not produce a valid subsea TVD."]},{"heading":"4. A final inclination cannot replace a deviation survey","paragraphs":["For an ideal straight segment of length L inclined by angle i from vertical, the vertical increment is L × cos(i). At L = 3,000 m, inclinations of 0°, 30° and 60° give vertical increments of 3,000 m, approximately 2,598.1 m and 1,500 m. The chart reproduces these fictional straight-segment calculations, rounded to 0.1 m. They are geometry checks, not drilled trajectories.","A real borehole changes inclination and azimuth along its path. Reconstructing TVD requires the appropriate survey stations, references and calculation method, with uncertainty and quality checks. Applying the maximum or final inclination to the entire MD invents a trajectory. The reported 3,050 and 3,020 m totals do not reveal all intermediate depths, lateral displacement, formation dip or true reservoir thickness."]},{"heading":"5. Hydrostatic pressure uses vertical fluid height","paragraphs":["For a static, continuous fluid column of uniform density, the pressure increment is density × gravitational acceleration × vertical height. In conventional oilfield units the rounded relation is pressure in psi = 0.052 × mud weight in pounds per US gallon × TVD in feet. This is an increment from the column’s reference pressure, not automatically an absolute reservoir pressure.","A fictional 12 ppg column spanning 10,000 ft vertically gives 6,240 psi using that coefficient. Substituting an unrelated 15,000 ft MD gives 9,360 psi, an overstatement of 3,120 psi or 50%. The erroneous result illustrates the reference mistake; it is not a second observation. Circulating friction, surface pressure, compressibility, temperature, gas and changing density require additional treatment. No mud-weight or well-control instruction is inferred from this classroom case."]},{"heading":"6. A LAS file is a data contract","paragraphs":["The USGS explanation of LAS identifies separate version, well, curve and ASCII-data sections. Read the file’s actual version and wrapping declaration, start/stop depths, step, curve order, mnemonics, units and null definition before interpreting the samples. A file extension or familiar curve name does not establish a complete depth reference, calibration history or permission to reuse the material.","If a teaching file declares NULL = −999.25, that value means missing in that file; it is not a physical log response or a universal sentinel to impose on all other files. Preserve genuine zero responses separately. A negative step can describe a decreasing-depth sequence, so reordering samples without preserving the source relationship is also a transformation that needs documenting. Unknown units remain unknown."]},{"heading":"7. Depth matching and thickness require more evidence","paragraphs":["Formation tops, cuttings, core intervals, wireline logs and drilling measurements need not share the same depth acquisition or correction history. Before overlaying them, establish the wellbore branch, run, reference and any documented depth shift. Keep the original values and the transformation separately. A visually attractive overlay does not validate a correlation.","An interval measured along hole is not automatically its true vertical thickness, and a vertical thickness is not necessarily true stratigraphic thickness in dipping beds. The well path and structural geometry matter. A gap between two reported formation tops can be a derived interval within a compatible reference; it is not proof that a contact was directly measured at every intermediate depth."]},{"heading":"8. Keep the atlas snapshot separate from today’s source page","paragraphs":["The Well Atlas record used here retains its existing source-check date of 2 October 2026. This article’s source reading on 8 November does not refresh the whole registry, certify the well’s present operational state or change the historical availability of its measurements. The current primary page and the retained reviewed edition are separate evidence objects, even when their displayed depth values agree.","Use the source-scoped record identifier to retrieve the documented borehole, preserve its attribution and terms, and follow its source record URL. The Norwegian Offshore Directorate attribution and NLOD 2.0 terms travel with the registry response. Public access does not settle every downstream reuse question. An absent temperature, depth datum or original available-at timestamp must not be filled by assuming today’s download was historically known."]},{"heading":"9. Build an auditable engineering decision","paragraphs":["A useful review package records the original document and revision, source access time, exact field or curve, unit and reference, branch identity, calculation inputs, sign convention, rounding and unresolved limitations. Store derived depths alongside their formula rather than silently overwriting the source total. A second calculation should reproduce the result from those inputs without needing an undocumented plotting adjustment.","These distinctions have economic value because interval placement, completion design and comparison of drilling progress depend on consistent coordinates. This guide assigns no invented dollar benefit to correcting a datum. A financial assessment would also need the actual programme, costs, uncertainty and consequences. The supported conclusion is narrower and useful: establish the coordinate contract before converting a depth into an engineering claim."]}],"text":"Well-log depth: MD, TVD and datum explained\n\nA petroleum-engineering guide to depth references, well logs and hydrostatic pressure, with a verified SODIR example and reproducible calculations.\n\nMD follows the borehole; TVD measures a vertical separation. A common unit does not make them interchangeable.\n\nFor SODIR 112, 3,050 m MD and 3,020 m TVD are reported from RKB. The 2,993 m depth below mean sea level is calculated using the reported 27 m RKB elevation.\n\nUnknown datums, missing log samples and unavailable historical vintages remain unknown; they are not zero or observed measurements.\n\nA depth without its measurement path, reference and unit is an incomplete engineering statement. Three numbers can describe the same bottomhole position while answering different questions: how far the borehole travels, how far down it goes, and where it sits relative to sea level. Confusing those questions can distort a geological correlation, a pressure calculation or a drilling comparison even when every copied number is accurate.\n\nThis guide separates published observations from calculations and fictional teaching cases. The real example is Norwegian Offshore Directorate wellbore 16/11-1 S, source identifier 112, checked on 8 November 2026. The geometry and drilling-fluid cases are independent mathematical examples. They do not reconstruct that borehole, estimate its present pressure or prescribe an operating programme.\n\n1. Start with the coordinate, not the largest number\n\nMeasured depth, MD, describes distance along a borehole. True vertical depth, TVD, describes the vertical separation from a stated reference. With the same starting point, a straight vertical hole has equal MD and TVD; a deviated path generally has a longer MD. A published total depth should therefore retain its depth type instead of being reduced to a generic depth field.\n\nSLB’s terminology distinguishes these uses, while BOEM’s borehole field definitions explicitly reference total MD and TVD to the rig kelly bushing. That is evidence about those fields, not permission to assign the same reference to every other dataset. A comparable record needs the quantity, unit, zero point, sign convention and source identity together.\n\n2. A datum shift is a vertical calculation\n\nDefine elevation as positive upward from mean sea level, MSL, and depth below MSL as positive downward. If the rotary kelly bushing, RKB, has elevation z_RKB, then depth_MSL = TVD_RKB − z_RKB. The subtraction changes the vertical reference; it does not convert MD into TVD. A different zero point or sign convention requires a separately stated transformation.\n\nThe historical UKOOA P7/2000 Revision 5 format distinguishes zero measured depth, zero true vertical depth and the permanent vertical datum. Its October 2002 terminology is a useful explanation of why a rig change or sidetrack can change the reference. It is not presented here as a new or mandatory reporting standard. Energistics’ WITSML 2.0 coordinate definition likewise carries datum and unit explicitly.\n\n3. Read one documented borehole carefully\n\nSODIR reports 16/11-1 S with total MD 3,050 m RKB, final TVD 3,020 m RKB, RKB elevation 27 m above MSL and water depth 67 m. These are source-reported values, not four measurements newly taken by Wellficent. The matching Well Atlas record is no-sodir-112: its sourceRecordId is 112 and its MD/TVD fields preserve the RKB reference. A text search also returns 7216/11-1 S, so a similar name alone is insufficient identification.\n\nUnder the sign convention above, the reported TVD gives 3,020 − 27 = 2,993 m below MSL. Subtracting the 67 m water depth gives a calculated 2,926 m vertical separation below the sea floor. Neither derived value replaces the source fields or constitutes an independent survey. In particular, subtracting 27 from the 3,050 m MD would not produce a valid subsea TVD.\n\n4. A final inclination cannot replace a deviation survey\n\nFor an ideal straight segment of length L inclined by angle i from vertical, the vertical increment is L × cos(i). At L = 3,000 m, inclinations of 0°, 30° and 60° give vertical increments of 3,000 m, approximately 2,598.1 m and 1,500 m. The chart reproduces these fictional straight-segment calculations, rounded to 0.1 m. They are geometry checks, not drilled trajectories.\n\nA real borehole changes inclination and azimuth along its path. Reconstructing TVD requires the appropriate survey stations, references and calculation method, with uncertainty and quality checks. Applying the maximum or final inclination to the entire MD invents a trajectory. The reported 3,050 and 3,020 m totals do not reveal all intermediate depths, lateral displacement, formation dip or true reservoir thickness.\n\n5. Hydrostatic pressure uses vertical fluid height\n\nFor a static, continuous fluid column of uniform density, the pressure increment is density × gravitational acceleration × vertical height. In conventional oilfield units the rounded relation is pressure in psi = 0.052 × mud weight in pounds per US gallon × TVD in feet. This is an increment from the column’s reference pressure, not automatically an absolute reservoir pressure.\n\nA fictional 12 ppg column spanning 10,000 ft vertically gives 6,240 psi using that coefficient. Substituting an unrelated 15,000 ft MD gives 9,360 psi, an overstatement of 3,120 psi or 50%. The erroneous result illustrates the reference mistake; it is not a second observation. Circulating friction, surface pressure, compressibility, temperature, gas and changing density require additional treatment. No mud-weight or well-control instruction is inferred from this classroom case.\n\n6. A LAS file is a data contract\n\nThe USGS explanation of LAS identifies separate version, well, curve and ASCII-data sections. Read the file’s actual version and wrapping declaration, start/stop depths, step, curve order, mnemonics, units and null definition before interpreting the samples. A file extension or familiar curve name does not establish a complete depth reference, calibration history or permission to reuse the material.\n\nIf a teaching file declares NULL = −999.25, that value means missing in that file; it is not a physical log response or a universal sentinel to impose on all other files. Preserve genuine zero responses separately. A negative step can describe a decreasing-depth sequence, so reordering samples without preserving the source relationship is also a transformation that needs documenting. Unknown units remain unknown.\n\n7. Depth matching and thickness require more evidence\n\nFormation tops, cuttings, core intervals, wireline logs and drilling measurements need not share the same depth acquisition or correction history. Before overlaying them, establish the wellbore branch, run, reference and any documented depth shift. Keep the original values and the transformation separately. A visually attractive overlay does not validate a correlation.\n\nAn interval measured along hole is not automatically its true vertical thickness, and a vertical thickness is not necessarily true stratigraphic thickness in dipping beds. The well path and structural geometry matter. A gap between two reported formation tops can be a derived interval within a compatible reference; it is not proof that a contact was directly measured at every intermediate depth.\n\n8. Keep the atlas snapshot separate from today’s source page\n\nThe Well Atlas record used here retains its existing source-check date of 2 October 2026. This article’s source reading on 8 November does not refresh the whole registry, certify the well’s present operational state or change the historical availability of its measurements. The current primary page and the retained reviewed edition are separate evidence objects, even when their displayed depth values agree.\n\nUse the source-scoped record identifier to retrieve the documented borehole, preserve its attribution and terms, and follow its source record URL. The Norwegian Offshore Directorate attribution and NLOD 2.0 terms travel with the registry response. Public access does not settle every downstream reuse question. An absent temperature, depth datum or original available-at timestamp must not be filled by assuming today’s download was historically known.\n\n9. Build an auditable engineering decision\n\nA useful review package records the original document and revision, source access time, exact field or curve, unit and reference, branch identity, calculation inputs, sign convention, rounding and unresolved limitations. Store derived depths alongside their formula rather than silently overwriting the source total. A second calculation should reproduce the result from those inputs without needing an undocumented plotting adjustment.\n\nThese distinctions have economic value because interval placement, completion design and comparison of drilling progress depend on consistent coordinates. This guide assigns no invented dollar benefit to correcting a datum. A financial assessment would also need the actual programme, costs, uncertainty and consequences. The supported conclusion is narrower and useful: establish the coordinate contract before converting a depth into an engineering claim.\n\nTechnical and economic analysis\n\nAnalysis as of: 2026-11-08\n\nEvidence cutoff: 2026-11-08\n\nOutlook horizon: Illustrative straight-segment geometry\n\nIllustrative sensitivity\n\nSame segment length, different vertical increments\n\nFictional ideal straight segments: L = 3,000 m; i measured from vertical; vertical increment = L × cos(i). Rounded to 0.1 m. Not real trajectories, measurements or a reconstruction of SODIR 112.\n\nThese calculations illustrate stated assumptions; they are not observations or a calibrated forecast.\n\ni = 0°: 3,000 vertical increment in metres\n\ni = 30°: 2,598.1 vertical increment in metres\n\ni = 60°: 1,500 vertical increment in metres","category":"energy","region":"world","topics":["oil","gas"],"eventDate":"2026-11-08","eventDateBasis":"analysis-as-of-date","publishedAt":"2026-11-08T14:54:15Z","modifiedAt":"2026-11-08T14:54:15Z","publicationBasis":"first-publication","preparedAt":"2026-11-08T14:42:43Z","sourcePublishedAt":null,"translatedAt":"2026-11-08T14:34:18Z","sources":[{"url":"https://factpages.sodir.no/en/wellbore/pageview/with/welllogs/112","name":"Norwegian Offshore Directorate — wellbore 16/11-1 S, source record 112","licence":"NLOD 2.0 — source terms apply","checkedAt":"2026-11-08","licenseUrl":"https://data.norge.no/nlod/en/2.0","attribution":"Norwegian Offshore Directorate (SODIR); source values distinguished from Wellficent calculations."},{"url":"https://glossary.slb.com/en/terms/m/measured_depth","name":"SLB Energy Glossary — measured depth","checkedAt":"2026-11-08"},{"url":"https://glossary.slb.com/en/terms/t/true_vertical_depth","name":"SLB Energy Glossary — true vertical depth","checkedAt":"2026-11-08"},{"url":"https://glossary.slb.com/en/terms/d/depth_reference","name":"SLB Energy Glossary — depth reference","checkedAt":"2026-11-08"},{"url":"https://glossary.slb.com/en/terms/h/hydrostatic_pressure","name":"SLB Energy Glossary — hydrostatic pressure","checkedAt":"2026-11-08"},{"url":"https://www.data.boem.gov/Main/HtmlPage.aspx?page=borehole","name":"BOEM Data Center — field definitions for boreholes","checkedAt":"2026-11-08"},{"url":"https://www.iogp.org/wp-content/uploads/2016/12/P7.pdf","name":"UKOOA — P7/2000 Revision 5, October 2002; historical well-deviation exchange format","checkedAt":"2026-11-08"},{"url":"https://docs.energistics.org/WITSML/WITSML_TOPICS/WITSML-500-449-0-R-sv2000.html","name":"Energistics — WITSML 2.0 MeasuredDepthCoord","checkedAt":"2026-11-08","publishedAt":"2016-11-11"},{"url":"https://www.usgs.gov/programs/national-geological-and-geophysical-data-preservation-program/las-format","name":"USGS — LAS format","checkedAt":"2026-11-08"},{"url":"https://wellficent.com/en/wells/record/no-sodir-112","name":"Wellficent Well Atlas — retained SODIR source record 112; additional internal reference","checkedAt":"2026-11-08"}],"translations":{"en":"https://wellficent.com/en/news/well-log-depth-md-tvd-datum-engineering-guide","tr":"https://wellficent.com/tr/news/well-log-depth-md-tvd-datum-engineering-guide","ar":"https://wellficent.com/ar/news/well-log-depth-md-tvd-datum-engineering-guide","fr":"https://wellficent.com/fr/news/well-log-depth-md-tvd-datum-engineering-guide","es":"https://wellficent.com/es/news/well-log-depth-md-tvd-datum-engineering-guide","ru":"https://wellficent.com/ru/news/well-log-depth-md-tvd-datum-engineering-guide","pt":"https://wellficent.com/pt/news/well-log-depth-md-tvd-datum-engineering-guide"},"corrections":[],"locations":[],"type":"analysis","analysis":{"asOf":"2026-11-08","kind":"technical-economic","chart":{"kind":"illustrative","note":{"ar":"قطع مستقيمة مثالية افتراضية: L = 3,000 م؛ i من الاتجاه الرأسي؛ الزيادة الرأسية = L × cos(i). التقريب إلى 0.1 م. ليست مسارات أو قياسات حقيقية أو إعادة بناء SODIR 112.","en":"Fictional ideal straight segments: L = 3,000 m; i measured from vertical; vertical increment = L × cos(i). Rounded to 0.1 m. Not real trajectories, measurements or a reconstruction of SODIR 112.","es":"Segmentos rectos ideales ficticios: L = 3.000 m; i desde la vertical; incremento = L × cos(i). Redondeo a 0,1 m. No son trayectorias, mediciones ni reconstrucción de SODIR 112.","fr":"Segments droits idéaux fictifs : L = 3 000 m ; i depuis la verticale ; incrément = L × cos(i). Arrondi à 0,1 m. Ni trajectoires réelles, ni mesures, ni reconstitution de SODIR 112.","pt":"Segmentos retos ideais fictícios: L = 3.000 m; i desde a vertical; incremento = L × cos(i). Arredondamento a 0,1 m. Não são trajetórias, medições ou reconstrução de SODIR 112.","ru":"Условные идеальные прямые отрезки: L = 3 000 м; i от вертикали; приращение = L × cos(i). Округление до 0,1 м. Не реальные траектории, измерения или реконструкция SODIR 112.","tr":"Kurmaca ideal düz parçalar: L = 3.000 m; i düşeyden ölçülür; düşey artış = L × cos(i). 0,1 m’ye yuvarlandı. Gerçek yörünge, ölçüm veya SODIR 112 rekonstrüksiyonu değildir."},"rows":[{"label":{"ar":"i = 0°","en":"i = 0°","es":"i = 0°","fr":"i = 0°","pt":"i = 0°","ru":"i = 0°","tr":"i = 0°"},"value":3000},{"label":{"ar":"i = 30°","en":"i = 30°","es":"i = 30°","fr":"i = 30°","pt":"i = 30°","ru":"i = 30°","tr":"i = 30°"},"value":2598.1},{"label":{"ar":"i = 60°","en":"i = 60°","es":"i = 60°","fr":"i = 60°","pt":"i = 60°","ru":"i = 60°","tr":"i = 60°"},"value":1500}],"unit":"m","title":{"ar":"طول واحد وزيادات رأسية مختلفة","en":"Same segment length, different vertical increments","es":"Misma longitud, distintos incrementos verticales","fr":"Même longueur, incréments verticaux différents","pt":"Mesmo comprimento, incrementos verticais diferentes","ru":"Одинаковая длина, разное вертикальное приращение","tr":"Aynı parça uzunluğu, farklı düşey artışlar"},"unitLabel":{"ar":"الزيادة الرأسية بالمتر","en":"vertical increment in metres","es":"incremento vertical en metros","fr":"incrément vertical en mètres","pt":"incremento vertical em metros","ru":"вертикальное приращение в метрах","tr":"metre cinsinden düşey artış"}},"horizon":"Illustrative straight-segment geometry","horizonLabel":{"ar":"هندسة توضيحية لقطع مستقيم","en":"Illustrative straight-segment geometry","es":"Geometría ilustrativa de segmentos rectos","fr":"Géométrie illustrative de segments droits","pt":"Geometria ilustrativa de segmentos retos","ru":"Условная геометрия прямых отрезков","tr":"Örnek düz parça geometrisi"},"evidenceCutoff":"2026-11-08"},"relatedArticles":[{"canonicalSlug":"oil-gas-production-data-rates-boe-decline-engineering-guide","url":"https://wellficent.com/en/news/oil-gas-production-data-rates-boe-decline-engineering-guide","title":"Oil and gas production data: rates, boe, decline and value","language":"en"},{"canonicalSlug":"refinery-capacity-calendar-stream-day-engineering-guide","url":"https://wellficent.com/en/news/refinery-capacity-calendar-stream-day-engineering-guide","title":"Refinery capacity: calendar day, stream day and actual throughput","language":"en"}],"image":{"url":"https://wellficent.com/media/bccfafeca328d8659e473763179eb4230006430da6abd5dd938d461b7acd18f4.webp","width":1600,"height":900,"alt":"Numerical graphic for SODIR wellbore 16/11-1 S: reported 3,050 m MD RKB and 3,020 m TVD RKB; 2,993 m below mean sea level calculated as 3,020 minus the 27 m RKB elevation. No well path is drawn.","credit":"Wellficent — original programmatic graphic and datum calculation. Data: Norwegian Offshore Directorate, NLOD 2.0, checked 8 November 2026. Not a photograph or independent survey.","licenseUrl":"https://data.norge.no/nlod/en/2.0"}}},{"requestedLanguage":"en","fallback":false,"record":{"id":"oil-gas-production-data-rates-boe-decline-engineering-guide","canonicalSlug":"oil-gas-production-data-rates-boe-decline-engineering-guide","url":"https://wellficent.com/en/news/oil-gas-production-data-rates-boe-decline-engineering-guide","language":"en","title":"Oil and gas production data: rates, boe, decline and value","summary":"An engineering guide to reading production disclosures, with reproducible examples of operating days, oil equivalent, ownership, decline and revenue.","body":["A production number becomes useful when its boundary is clear. Ask which asset it covers, which fluid was measured, where it was measured, over what period, and on whose economic interest. A project capacity, a short well test and a corporate quarterly average answer different questions. Putting them in one league table without those distinctions can produce an impressive ranking with little engineering meaning.","This guide connects the measurement distinctions behind Wellficent’s corrected project reporting with practical petroleum-engineering arithmetic. The Troll field example uses reported Norwegian Offshore Directorate volumes. The other numerical examples use fictional inputs. EIA definitions and InPlay’s oil-equivalent disclosure establish terminology for those calculations."],"keyPoints":[],"sections":[{"heading":"1. Define the reporting boundary before comparing production","paragraphs":["A well, borehole branch, reservoir, field, production installation and corporate portfolio are different reporting entities. An operator’s field total cannot be assigned equally to its wells without allocation evidence. Similarly, a source identifier is an address within a dataset, not proof that another catalogue describes the same physical borehole. Preserve the source’s entity and scope before attempting any comparison.","Gas needs an additional process boundary. EIA distinguishes gross withdrawals, marketed production and dry-gas production; treatment, reinjection and other deductions matter. Comparing those series as though they were the same stream can create artificial growth or loss. Record the exact measure definition. A pipeline export flow is also not automatically the reservoir’s total gas production."]},{"heading":"2. Convert rates to volumes using the right clock","paragraphs":["Suppose a fictional oil well averages 1,000 barrels per operating day and runs on 24 days in a 30-day reporting month. Its period volume is 1,000 × 24 = 24,000 barrels; its average over all calendar days is 24,000 ÷ 30 = 800 barrels per day. Multiplying the operating-day rate by all 30 days instead would overstate this example’s volume by 6,000 barrels.","The same problem appears when a peak hourly rate is multiplied into a year, or a month-end exit rate is compared with a quarter average. Use an integrated meter total where available. If only an average is reported, identify its denominator and treatment of downtime. Do not multiply an already calendar-averaged rate by an availability factor again: that would count the same outage twice.","The Norwegian Offshore Directorate’s monthly series for the Troll field (NPDID 46437) reports 0.180357 million Sm³ of net oil in January 2024 and 0.175851 million Sm³ in February. The unit is standard cubic metres and the figures cover the field. To reproduce the calendar-day averages, multiply each source volume by one million and divide by the number of calendar days. January gives 180,357 ÷ 31 = 5,817.97 Sm³/d. February gives 175,851 ÷ 29 = 6,063.83 Sm³/d because 2024 was a leap year.","February’s period volume fell by 2.50% while its calendar-day average rose by 4.23%. Both percentages use January as the denominator. These observations measure two field reporting periods. A reservoir decline fit needs a longer rate history, a consistent reporting boundary and evidence of downtime, operating changes and well additions. The linked Well Atlas selection preserves the two monthly observations, the net-oil source field and the dataset attribution."]},{"heading":"3. Oil equivalent is a conversion convention","paragraphs":["InPlay’s release discloses a ratio of 6 Mcf of gas to 1 barrel of oil equivalent and warns against reading it as value equivalence. Here Mcf means one thousand cubic feet. A fictional stream of 900 barrels of oil per day plus 600 Mcf of gas per day therefore becomes 900 + 600 ÷ 6 = 1,000 boe/d under that stated convention. The gas contribution is 100 boe/d; it is not another 600 oil barrels.","Keep the original fluid quantities beside the converted total. EIA explains that fuel heat contents vary, so a reporting convention should not be silently substituted for a measured gas heating value. Gas pressure and temperature reference conditions, composition and liquid classification also matter. Use the source’s stated conversion factor when reproducing its disclosure; do not invent one for a record that lacks it."]},{"heading":"4. Gross, working interest and entitlement describe different things","paragraphs":["Assume, independently, a gross project rate of 1,000 boe/d and a constant 40% working interest. Simple proportion gives 400 boe/d attributable on that working-interest basis. It is an arithmetic illustration, not the net production of a named company. It does not yet account for royalties, production-sharing terms, tax, lifting timing, sales inventory or any other contractual adjustment.","The word net needs its own definition. Net after royalty can differ from working-interest production; a contractual entitlement can vary with terms and period. Operatorship is a responsibility, not proof of full ownership. A graph should store a documented operator relationship separately from an ownership share and retain the effective date rather than treating today’s company name as an eternal asset attribute."]},{"heading":"5. An initial rate does not determine annual output","paragraphs":["An IP30 value describes the stated initial measurement window. Check whether the issuer uses calendar days or producing days and whether cleanup, interruptions or allocated production are included. One early-rate statistic cannot identify a unique decline curve. Reservoir pressure, drawdown, completion design, choke settings, fluid behaviour and subsequent operating history can change the trajectory.","For the chart only, assume an uninterrupted fictional oil stream with initial rate q₀ = 1,000 b/d and q(t) = q₀ × exp(−D × t), where t is in years and D is a constant nominal continuous decline parameter per year. Integrating over one assumed 365-day year gives V = 365 × q₀ × (1 − exp(−D)) ÷ D. At D = 0 use the constant-rate limit, V = 365 × q₀.","The calculated volumes, rounded to whole barrels, are 365,000 at D = 0, 330,816 at D = 0.20 and 287,233 at D = 0.50. These continuous parameters are not the effective percentage fall between year-start and year-end. No parameter was fitted to real wells; no probabilities, forecast interval, economic limit or recoverable-reserve estimate is supplied. The purpose is to show why the starting rate alone is insufficient."]},{"heading":"6. Produced water is a separate engineering load","paragraphs":["In another independent example, a liquid stream of 1,000 barrels per day at 80% water cut contains 800 barrels of produced water and 200 barrels of oil per day, assuming compatible surface-volume conditions and water cut defined as water divided by oil plus water. Gas does not belong in that liquid-volume denominator. A fluid total without its composition can therefore conceal a very different oil rate.","Produced-water handling can constrain separation, lifting, treatment and disposal, but its presence does not identify a groundwater-monitoring or water-supply well. Neither water cut nor a surface separator reading establishes reservoir permeability or equipment pressure rating. Those require their own observations, reference conditions and source documents. A well log can provide relevant subsurface evidence while still needing its native mnemonic, unit, depth reference and quality flags."]},{"heading":"7. Value the saleable products rather than the boe headline","paragraphs":["Return to the fictional 900 b/d oil and 600 Mcf/d gas stream. Assume every unit is saleable on the same gross basis, with hypothetical realised prices of US$60 per oil barrel and US$2.50 per Mcf. Gross daily revenue is 900 × 60 + 600 × 2.50 = US$55,500. Pricing all 1,000 boe at the oil price would instead give US$60,000, an excess of US$4,500 in this example.","These are assumed prices, not current market quotes or a company netback. The calculation excludes shrinkage, quality differentials, transport, processing, water handling, operating cost, capital, financing, royalties and tax. A useful project comparison needs consistent product prices, ownership boundaries and dated cash flows. Production alone does not establish profit, cash generation or the value of an EPC contract."]},{"heading":"8. Keep the evidence reproducible and the connections honest","paragraphs":["For each observation retain the source URL and record identifier, entity scope, fluid or measure, raw value and unit, reference conditions, period start and end, source publication date, retrieval time and any genuinely evidenced historical availability. Preserve approval and confidentiality flags. An absent value stays unknown; a real reported zero stays zero. Downloading an old production period today does not prove that the same vintage was available to an analyst in that period.","Before publishing a comparison, reproduce the arithmetic from the retained inputs, reconcile the fluid and time denominators, and label observation, target, interpretation and illustrative scenario separately. Related reading can explain a shared measurement problem without asserting a physical connection. Ownership, operator, field-to-well allocation, pipeline delivery and refinery supply each require their own dated evidence. That separation makes connected reporting useful to engineers and readers who need to inspect its limits."]}],"text":"Oil and gas production data: rates, boe, decline and value\n\nAn engineering guide to reading production disclosures, with reproducible examples of operating days, oil equivalent, ownership, decline and revenue.\n\nA production number becomes useful when its boundary is clear. Ask which asset it covers, which fluid was measured, where it was measured, over what period, and on whose economic interest. A project capacity, a short well test and a corporate quarterly average answer different questions. Putting them in one league table without those distinctions can produce an impressive ranking with little engineering meaning.\n\nThis guide connects the measurement distinctions behind Wellficent’s corrected project reporting with practical petroleum-engineering arithmetic. The Troll field example uses reported Norwegian Offshore Directorate volumes. The other numerical examples use fictional inputs. EIA definitions and InPlay’s oil-equivalent disclosure establish terminology for those calculations.\n\n1. Define the reporting boundary before comparing production\n\nA well, borehole branch, reservoir, field, production installation and corporate portfolio are different reporting entities. An operator’s field total cannot be assigned equally to its wells without allocation evidence. Similarly, a source identifier is an address within a dataset, not proof that another catalogue describes the same physical borehole. Preserve the source’s entity and scope before attempting any comparison.\n\nGas needs an additional process boundary. EIA distinguishes gross withdrawals, marketed production and dry-gas production; treatment, reinjection and other deductions matter. Comparing those series as though they were the same stream can create artificial growth or loss. Record the exact measure definition. A pipeline export flow is also not automatically the reservoir’s total gas production.\n\n2. Convert rates to volumes using the right clock\n\nSuppose a fictional oil well averages 1,000 barrels per operating day and runs on 24 days in a 30-day reporting month. Its period volume is 1,000 × 24 = 24,000 barrels; its average over all calendar days is 24,000 ÷ 30 = 800 barrels per day. Multiplying the operating-day rate by all 30 days instead would overstate this example’s volume by 6,000 barrels.\n\nThe same problem appears when a peak hourly rate is multiplied into a year, or a month-end exit rate is compared with a quarter average. Use an integrated meter total where available. If only an average is reported, identify its denominator and treatment of downtime. Do not multiply an already calendar-averaged rate by an availability factor again: that would count the same outage twice.\n\nThe Norwegian Offshore Directorate’s monthly series for the Troll field (NPDID 46437) reports 0.180357 million Sm³ of net oil in January 2024 and 0.175851 million Sm³ in February. The unit is standard cubic metres and the figures cover the field. To reproduce the calendar-day averages, multiply each source volume by one million and divide by the number of calendar days. January gives 180,357 ÷ 31 = 5,817.97 Sm³/d. February gives 175,851 ÷ 29 = 6,063.83 Sm³/d because 2024 was a leap year.\n\nFebruary’s period volume fell by 2.50% while its calendar-day average rose by 4.23%. Both percentages use January as the denominator. These observations measure two field reporting periods. A reservoir decline fit needs a longer rate history, a consistent reporting boundary and evidence of downtime, operating changes and well additions. The linked Well Atlas selection preserves the two monthly observations, the net-oil source field and the dataset attribution.\n\n3. Oil equivalent is a conversion convention\n\nInPlay’s release discloses a ratio of 6 Mcf of gas to 1 barrel of oil equivalent and warns against reading it as value equivalence. Here Mcf means one thousand cubic feet. A fictional stream of 900 barrels of oil per day plus 600 Mcf of gas per day therefore becomes 900 + 600 ÷ 6 = 1,000 boe/d under that stated convention. The gas contribution is 100 boe/d; it is not another 600 oil barrels.\n\nKeep the original fluid quantities beside the converted total. EIA explains that fuel heat contents vary, so a reporting convention should not be silently substituted for a measured gas heating value. Gas pressure and temperature reference conditions, composition and liquid classification also matter. Use the source’s stated conversion factor when reproducing its disclosure; do not invent one for a record that lacks it.\n\n4. Gross, working interest and entitlement describe different things\n\nAssume, independently, a gross project rate of 1,000 boe/d and a constant 40% working interest. Simple proportion gives 400 boe/d attributable on that working-interest basis. It is an arithmetic illustration, not the net production of a named company. It does not yet account for royalties, production-sharing terms, tax, lifting timing, sales inventory or any other contractual adjustment.\n\nThe word net needs its own definition. Net after royalty can differ from working-interest production; a contractual entitlement can vary with terms and period. Operatorship is a responsibility, not proof of full ownership. A graph should store a documented operator relationship separately from an ownership share and retain the effective date rather than treating today’s company name as an eternal asset attribute.\n\n5. An initial rate does not determine annual output\n\nAn IP30 value describes the stated initial measurement window. Check whether the issuer uses calendar days or producing days and whether cleanup, interruptions or allocated production are included. One early-rate statistic cannot identify a unique decline curve. Reservoir pressure, drawdown, completion design, choke settings, fluid behaviour and subsequent operating history can change the trajectory.\n\nFor the chart only, assume an uninterrupted fictional oil stream with initial rate q₀ = 1,000 b/d and q(t) = q₀ × exp(−D × t), where t is in years and D is a constant nominal continuous decline parameter per year. Integrating over one assumed 365-day year gives V = 365 × q₀ × (1 − exp(−D)) ÷ D. At D = 0 use the constant-rate limit, V = 365 × q₀.\n\nThe calculated volumes, rounded to whole barrels, are 365,000 at D = 0, 330,816 at D = 0.20 and 287,233 at D = 0.50. These continuous parameters are not the effective percentage fall between year-start and year-end. No parameter was fitted to real wells; no probabilities, forecast interval, economic limit or recoverable-reserve estimate is supplied. The purpose is to show why the starting rate alone is insufficient.\n\n6. Produced water is a separate engineering load\n\nIn another independent example, a liquid stream of 1,000 barrels per day at 80% water cut contains 800 barrels of produced water and 200 barrels of oil per day, assuming compatible surface-volume conditions and water cut defined as water divided by oil plus water. Gas does not belong in that liquid-volume denominator. A fluid total without its composition can therefore conceal a very different oil rate.\n\nProduced-water handling can constrain separation, lifting, treatment and disposal, but its presence does not identify a groundwater-monitoring or water-supply well. Neither water cut nor a surface separator reading establishes reservoir permeability or equipment pressure rating. Those require their own observations, reference conditions and source documents. A well log can provide relevant subsurface evidence while still needing its native mnemonic, unit, depth reference and quality flags.\n\n7. Value the saleable products rather than the boe headline\n\nReturn to the fictional 900 b/d oil and 600 Mcf/d gas stream. Assume every unit is saleable on the same gross basis, with hypothetical realised prices of US$60 per oil barrel and US$2.50 per Mcf. Gross daily revenue is 900 × 60 + 600 × 2.50 = US$55,500. Pricing all 1,000 boe at the oil price would instead give US$60,000, an excess of US$4,500 in this example.\n\nThese are assumed prices, not current market quotes or a company netback. The calculation excludes shrinkage, quality differentials, transport, processing, water handling, operating cost, capital, financing, royalties and tax. A useful project comparison needs consistent product prices, ownership boundaries and dated cash flows. Production alone does not establish profit, cash generation or the value of an EPC contract.\n\n8. Keep the evidence reproducible and the connections honest\n\nFor each observation retain the source URL and record identifier, entity scope, fluid or measure, raw value and unit, reference conditions, period start and end, source publication date, retrieval time and any genuinely evidenced historical availability. Preserve approval and confidentiality flags. An absent value stays unknown; a real reported zero stays zero. Downloading an old production period today does not prove that the same vintage was available to an analyst in that period.\n\nBefore publishing a comparison, reproduce the arithmetic from the retained inputs, reconcile the fluid and time denominators, and label observation, target, interpretation and illustrative scenario separately. Related reading can explain a shared measurement problem without asserting a physical connection. Ownership, operator, field-to-well allocation, pipeline delivery and refinery supply each require their own dated evidence. That separation makes connected reporting useful to engineers and readers who need to inspect its limits.\n\nTechnical and economic analysis\n\nAnalysis as of: 2026-11-11\n\nEvidence cutoff: 2026-11-11\n\nOutlook horizon: Illustrative 365-day year\n\nIllustrative sensitivity\n\nSame initial oil rate, different calculated annual volumes\n\nFictional q₀ = 1,000 oil b/d; 365 days, no downtime. D is a nominal continuous annual parameter, not an effective yearly percentage decline. Whole-barrel rounding; no fitted well data, probabilities or reserves.\n\nThese calculations illustrate stated assumptions; they are not observations or a calibrated forecast.\n\nD = 0: 365,000 barrels in the assumed year\n\nD = 0.20: 330,816 barrels in the assumed year\n\nD = 0.50: 287,233 barrels in the assumed year","category":"energy","region":"world","topics":["oil","gas","finance"],"eventDate":"2026-11-11","eventDateBasis":"analysis-as-of-date","publishedAt":"2026-11-08T10:59:21Z","modifiedAt":"2026-11-11T00:11:56Z","publicationBasis":"first-publication","preparedAt":"2026-11-08T10:56:44Z","sourcePublishedAt":null,"translatedAt":"2026-11-08T10:39:11Z","sources":[{"url":"https://www.eia.gov/energyexplained/units-and-calculators/","name":"U.S. EIA — Energy units and calculators explained","checkedAt":"2026-11-08"},{"url":"https://www.eia.gov/dnav/ng/TblDefs/ng_prod_sum_tbldef.asp","name":"U.S. EIA — Natural gas production definitions","checkedAt":"2026-11-08"},{"url":"https://www.inplayoil.com/sites/default/files/2026-11/Press%20Release%20-%20Q3%202026%20%28vf%29.pdf","name":"InPlay Oil Corp. — Q3 2026 results and BOE disclosure","checkedAt":"2026-11-08","publishedAt":"2026-11-05"},{"url":"https://factmaps.sodir.no/api/rest/services/DataService/Data/FeatureServer/7300/query?where=prfNpdidInformationCarrier%3D46437+AND+prfYear%3D2024+AND+prfMonth+IN+%281%2C2%29+AND+prfPeriod%3D%27month%27&outFields=OBJECTID%2CprfYear%2CprfMonth%2CprfInformationCarrier%2CprfInformationCarrierKind%2CprfPrdOilNetMillSm3&orderByFields=prfMonth&returnGeometry=false&f=json","name":"Norwegian Offshore Directorate — Troll monthly net oil, January and February 2024","licence":"NLOD 2.0","checkedAt":"2026-11-11","licenseUrl":"https://data.norge.no/nlod/en/2.0","attribution":"Contains data under NLOD distributed by the Norwegian Offshore Directorate."},{"url":"https://wellficent.com/en/wells/evidence?dataset=sodir-production&entity=sodir-field-46437&frequency=monthly&from=2024-01-01&to=2024-02-29&incomplete=exclude","name":"Wellficent Well Atlas — two Troll field production observations","checkedAt":"2026-11-11"}],"translations":{"en":"https://wellficent.com/en/news/oil-gas-production-data-rates-boe-decline-engineering-guide","tr":"https://wellficent.com/tr/news/oil-gas-production-data-rates-boe-decline-engineering-guide","ar":"https://wellficent.com/ar/news/oil-gas-production-data-rates-boe-decline-engineering-guide","fr":"https://wellficent.com/fr/news/oil-gas-production-data-rates-boe-decline-engineering-guide","es":"https://wellficent.com/es/news/oil-gas-production-data-rates-boe-decline-engineering-guide","ru":"https://wellficent.com/ru/news/oil-gas-production-data-rates-boe-decline-engineering-guide","pt":"https://wellficent.com/pt/news/oil-gas-production-data-rates-boe-decline-engineering-guide"},"corrections":[{"at":"2026-11-11T00:11:56Z","language":"en","text":"Added a verified Troll field example showing how different calendar-month lengths affect comparisons of reported net oil volumes and daily averages. Linked the original data and the two Well Atlas observations."}],"locations":[],"type":"analysis","analysis":{"asOf":"2026-11-11","kind":"technical-economic","chart":{"kind":"illustrative","note":{"ar":"q₀ افتراضي = 1,000 برميل نفط/يوم؛ 365 يوماً دون توقف. D معامل اسمي مستمر سنوي وليس نسبة تراجع سنوية فعلية. تقريب لبراميل كاملة؛ بلا بيانات آبار ملائمة أو احتمالات أو احتياطيات.","en":"Fictional q₀ = 1,000 oil b/d; 365 days, no downtime. D is a nominal continuous annual parameter, not an effective yearly percentage decline. Whole-barrel rounding; no fitted well data, probabilities or reserves.","es":"q₀ ficticio = 1.000 b/d de petróleo; 365 días sin paradas. D es un parámetro nominal continuo anual, no un declive porcentual anual efectivo. Redondeo a barriles enteros; sin ajuste a pozos, probabilidades ni reservas.","fr":"q₀ fictif = 1 000 b/j de pétrole ; 365 jours sans arrêt. D est un paramètre nominal continu annuel, pas un pourcentage effectif de baisse annuelle. Arrondi au baril ; ni ajustement à des puits, ni probabilités, ni réserves.","pt":"q₀ fictício = 1.000 b/d de petróleo; 365 dias sem paradas. D é parâmetro nominal contínuo anual, não queda percentual anual efetiva. Arredondamento a barris inteiros; sem ajuste a poços, probabilidades ou reservas.","ru":"Условный q₀ = 1 000 барр./сут нефти; 365 дней без простоев. D — номинальный непрерывный годовой параметр, не эффективный годовой процент падения. Округление до барреля; без подбора по скважинам, вероятностей и запасов.","tr":"Kurmaca q₀ = 1.000 varil petrol/gün; 365 gün, duruş yok. D nominal sürekli yıllık parametredir; etkin yıllık yüzde düşüş değildir. Tam varile yuvarlandı; gerçek kuyu uyarlaması, olasılık veya rezerv yok."},"rows":[{"label":{"ar":"D = 0","en":"D = 0","es":"D = 0","fr":"D = 0","pt":"D = 0","ru":"D = 0","tr":"D = 0"},"value":365000},{"label":{"ar":"D = 0.20","en":"D = 0.20","es":"D = 0.20","fr":"D = 0.20","pt":"D = 0.20","ru":"D = 0.20","tr":"D = 0.20"},"value":330816},{"label":{"ar":"D = 0.50","en":"D = 0.50","es":"D = 0.50","fr":"D = 0.50","pt":"D = 0.50","ru":"D = 0.50","tr":"D = 0.50"},"value":287233}],"unit":"bbl/year","title":{"ar":"معدل نفط أولي واحد وأحجام سنوية محسوبة مختلفة","en":"Same initial oil rate, different calculated annual volumes","es":"Mismo caudal inicial, distintos volúmenes anuales calculados","fr":"Même débit initial, volumes annuels calculés différents","pt":"Mesma vazão inicial, diferentes volumes anuais calculados","ru":"Одинаковый начальный дебит, разные расчётные годовые объёмы","tr":"Aynı başlangıç petrol debisi, farklı hesaplanan yıllık hacimler"},"unitLabel":{"ar":"برميل خلال السنة المفترضة","en":"barrels in the assumed year","es":"barriles en el año supuesto","fr":"barils sur l’année supposée","pt":"barris no ano suposto","ru":"баррелей за условный год","tr":"varsayılan yıldaki varil"}},"horizon":"Illustrative 365-day year","horizonLabel":{"ar":"سنة توضيحية من 365 يوماً","en":"Illustrative 365-day year","es":"Año ilustrativo de 365 días","fr":"Année illustrative de 365 jours","pt":"Ano ilustrativo de 365 dias","ru":"Условный год из 365 дней","tr":"Örnek 365 günlük yıl"},"evidenceCutoff":"2026-11-11"},"relatedArticles":[{"canonicalSlug":"inplay-oil-pembina-cardium-q3-production-drilling-nov2026","url":"https://wellficent.com/en/news/inplay-oil-pembina-cardium-q3-production-drilling-nov2026","title":"InPlay’s verified Q3 results: 19,254 boe/d and a separate 2027 outlook","language":"en"},{"canonicalSlug":"chevron-ballymore-deepwater-gulf-of-mexico-oil-production-nov2026","url":"https://wellficent.com/en/news/chevron-ballymore-deepwater-gulf-of-mexico-oil-production-nov2026","title":"Ballymore first production: the April 2025 milestone and Blind Faith tieback","language":"en"},{"canonicalSlug":"refinery-capacity-calendar-stream-day-engineering-guide","url":"https://wellficent.com/en/news/refinery-capacity-calendar-stream-day-engineering-guide","title":"Refinery capacity: calendar day, stream day and actual throughput","language":"en"},{"canonicalSlug":"drill-results-downhole-length-true-width-cueq-engineering-guide","url":"https://wellficent.com/en/news/drill-results-downhole-length-true-width-cueq-engineering-guide","title":"Reading drill results: downhole length, true width and copper equivalent","language":"en"}],"image":{"url":"https://wellficent.com/media/097db407c82d64c30506b7176539d98dd4502458b408bd7b69cf11179a8d77af.webp","width":1672,"height":941,"alt":"Conceptual oilfield illustration with a wellhead, test separator and metering pipes; no real field or measured configuration is depicted.","credit":"Wellficent / OpenAI — AI-generated conceptual illustration; not a photograph, actual facility depiction or engineering evidence.","licenseUrl":"https://openai.com/policies/terms-of-use/"}}},{"requestedLanguage":"en","fallback":false,"record":{"id":"drill-results-downhole-length-true-width-cueq-engineering-guide","canonicalSlug":"drill-results-downhole-length-true-width-cueq-engineering-guide","url":"https://wellficent.com/en/news/drill-results-downhole-length-true-width-cueq-engineering-guide","language":"en","title":"Reading drill results: downhole length, true width and copper equivalent","summary":"A source-based engineering guide to interval geometry, nested assays, selective samples and CuEq, with a deterministic hypothetical thickness calculation.","body":["A drilling result needs more than a length and a grade. Identify the hole, depth endpoints, unit, sampling support and whether a width was measured along the hole or estimated perpendicular to the mineralized body. Measured depth, vertical depth and mineralized thickness describe different quantities. Converting between them requires the appropriate survey and geological geometry; an unspecified reference must remain unknown.","NorthWest Copper’s 29 October 2026 Kwanika table reports 73.9 metres downhole in K-26-260 and an estimated true width of 49.4 metres. Orvana’s same-day OroValle table reports 26BX1094 from 99.90 to 104.90 metres, a calculated downhole interval of 5.00 metres, but approximate true width of 4.17 metres. These are source-specific estimates, not interchangeable measurements or universal conversion factors.","Gladiator reports 36.0 metres at 2.63% copper in CPG-176, including 20.0 metres at 3.61%. The included interval is already inside the larger one: adding the lengths to obtain 56.0 metres would double-count part of the sample. Its disclosure says complex skarn geometry prevents a reliable true-width estimate. No angle or missing width should be manufactured.","For the chart, assume a fictional straight 20-metre interval crossing an ideal planar layer. Let α be the angle between the borehole and that plane, not the angle to the ground surface. Perpendicular thickness is t = L × sin(α): 10.00 metres at 30°, 14.14 metres at 45° and 20.00 metres at 90°. Values are rounded to two decimals. This geometric illustration does not estimate any cited deposit; folds, variable geometry and uncertain orientation require a different interpretation.","Grade also needs a basis. NorthWest’s 1.39% CuEq accompanies an actual copper assay of 0.51%; the equivalent combines metals using the issuer’s price and recovery assumptions. It is not a 1.39% copper assay or measured commercial recovery. Amaroq’s separate 62.2% zinc rock-chip result is selective and does not represent the average deposit or mine feed.","The practical reading sequence is identity and date, length definition, assay unit, nested intervals, geometry, then economic assumptions. Exploration assays and illustrative arithmetic do not establish mineable tonnage, reserves or a production forecast. The cited reports were read; this guide is not an independent resource audit, and no confidence interval for the source width estimates was supplied here."],"keyPoints":[],"sections":[],"text":"Reading drill results: downhole length, true width and copper equivalent\n\nA source-based engineering guide to interval geometry, nested assays, selective samples and CuEq, with a deterministic hypothetical thickness calculation.\n\nA drilling result needs more than a length and a grade. Identify the hole, depth endpoints, unit, sampling support and whether a width was measured along the hole or estimated perpendicular to the mineralized body. Measured depth, vertical depth and mineralized thickness describe different quantities. Converting between them requires the appropriate survey and geological geometry; an unspecified reference must remain unknown.\n\nNorthWest Copper’s 29 October 2026 Kwanika table reports 73.9 metres downhole in K-26-260 and an estimated true width of 49.4 metres. Orvana’s same-day OroValle table reports 26BX1094 from 99.90 to 104.90 metres, a calculated downhole interval of 5.00 metres, but approximate true width of 4.17 metres. These are source-specific estimates, not interchangeable measurements or universal conversion factors.\n\nGladiator reports 36.0 metres at 2.63% copper in CPG-176, including 20.0 metres at 3.61%. The included interval is already inside the larger one: adding the lengths to obtain 56.0 metres would double-count part of the sample. Its disclosure says complex skarn geometry prevents a reliable true-width estimate. No angle or missing width should be manufactured.\n\nFor the chart, assume a fictional straight 20-metre interval crossing an ideal planar layer. Let α be the angle between the borehole and that plane, not the angle to the ground surface. Perpendicular thickness is t = L × sin(α): 10.00 metres at 30°, 14.14 metres at 45° and 20.00 metres at 90°. Values are rounded to two decimals. This geometric illustration does not estimate any cited deposit; folds, variable geometry and uncertain orientation require a different interpretation.\n\nGrade also needs a basis. NorthWest’s 1.39% CuEq accompanies an actual copper assay of 0.51%; the equivalent combines metals using the issuer’s price and recovery assumptions. It is not a 1.39% copper assay or measured commercial recovery. Amaroq’s separate 62.2% zinc rock-chip result is selective and does not represent the average deposit or mine feed.\n\nThe practical reading sequence is identity and date, length definition, assay unit, nested intervals, geometry, then economic assumptions. Exploration assays and illustrative arithmetic do not establish mineable tonnage, reserves or a production forecast. The cited reports were read; this guide is not an independent resource audit, and no confidence interval for the source width estimates was supplied here.\n\nTechnical and economic analysis\n\nAnalysis as of: 2026-11-05\n\nEvidence cutoff: 2026-11-05\n\nOutlook horizon: Source definitions and illustrative geometry\n\nIllustrative sensitivity\n\nHypothetical perpendicular thickness for a 20-metre downhole interval\n\nFictional straight 20 m interval through an ideal planar layer: t = 20 × sin(α). α is the angle between borehole and layer plane, not the ground surface. Values rounded to two decimals; not field measurements or estimates of the cited deposits.\n\nThese calculations illustrate stated assumptions; they are not observations or a calibrated forecast.\n\n30° between borehole and layer plane: 10 metres\n\n45° between borehole and layer plane: 14.14 metres\n\n90° between borehole and layer plane: 20 metres","category":"energy","region":"world","topics":["mining","metals"],"eventDate":"2026-11-05","eventDateBasis":"analysis-as-of-date","publishedAt":"2026-11-05T23:43:08Z","modifiedAt":"2026-11-05T23:43:08Z","publicationBasis":"first-publication","preparedAt":"2026-11-05T23:42:58Z","sourcePublishedAt":"2026-10-29","translatedAt":"2026-11-05T23:40:05Z","sources":[{"url":"https://northwestcopper.ca/news/northwest-intersects-73-9-metres-of-1-39-cueq-0-16359/","name":"NorthWest Copper — Kwanika Western Zone results","checkedAt":"2026-11-05","publishedAt":"2026-10-29"},{"url":"https://www.orvana.com/English/news/news-details/2026/ORVANA-REPORTS-H2-FY2026-EXPLORATION-RESULTS-AT-OROVALLE-SPAIN/default.aspx","name":"Orvana Minerals — H2 FY2026 OroValle exploration results","checkedAt":"2026-11-05","publishedAt":"2026-10-29"},{"url":"https://www.nsx.com.au/ftp/news/021745702.PDF","name":"Gladiator Metals — 29 October issuer release filed with NSX","checkedAt":"2026-11-05","publishedAt":"2026-10-29"},{"url":"https://www.mfn.se/one/a/amaroq/maarmorilik-project-development-strategy-and-high-grade-results-from-2026-exploration-programme-d5cf7272","name":"Amaroq — technical disclosure in issuer release distributed by MFN","checkedAt":"2026-11-05","publishedAt":"2026-11-02"}],"translations":{"en":"https://wellficent.com/en/news/drill-results-downhole-length-true-width-cueq-engineering-guide","tr":"https://wellficent.com/tr/news/drill-results-downhole-length-true-width-cueq-engineering-guide","ar":"https://wellficent.com/ar/news/drill-results-downhole-length-true-width-cueq-engineering-guide","fr":"https://wellficent.com/fr/news/drill-results-downhole-length-true-width-cueq-engineering-guide","es":"https://wellficent.com/es/news/drill-results-downhole-length-true-width-cueq-engineering-guide","ru":"https://wellficent.com/ru/news/drill-results-downhole-length-true-width-cueq-engineering-guide","pt":"https://wellficent.com/pt/news/drill-results-downhole-length-true-width-cueq-engineering-guide"},"corrections":[],"locations":[],"type":"analysis","analysis":{"asOf":"2026-11-05","kind":"technical-economic","chart":{"kind":"illustrative","note":{"ar":"فاصل مستقيم خيالي بطول 20 م عبر طبقة مستوية مثالية: t = 20 × sin(α). α زاوية الحفرة مع مستوى الطبقة، لا سطح الأرض. القيم مقربة لمنزلتين؛ ليست قياسات ميدانية أو تقديرات للرواسب المذكورة.","en":"Fictional straight 20 m interval through an ideal planar layer: t = 20 × sin(α). α is the angle between borehole and layer plane, not the ground surface. Values rounded to two decimals; not field measurements or estimates of the cited deposits.","es":"Intervalo recto ficticio de 20 m a través de una capa plana ideal: t = 20 × sin(α). α es el ángulo entre sondeo y plano de la capa, no la superficie. Redondeado a dos decimales; no son mediciones de campo ni estimaciones de los depósitos citados.","fr":"Intervalle rectiligne fictif de 20 m à travers une couche plane idéale : t = 20 × sin(α). α est l’angle entre forage et plan de la couche, non la surface du sol. Arrondi à deux décimales ; ni mesures de terrain, ni estimations des gisements cités.","pt":"Intervalo reto fictício de 20 m através de camada plana ideal: t = 20 × sin(α). α é o ângulo entre furo e plano da camada, não a superfície. Arredondado a duas casas; não são medições de campo ou estimativas dos depósitos citados.","ru":"Вымышленный прямой интервал 20 м через идеальный плоский пласт: t = 20 × sin(α). α — угол между стволом и плоскостью пласта, не земной поверхностью. Округление до двух знаков; не полевые измерения или оценки названных залежей.","tr":"İdeal düzlemsel tabakayı kesen hayali, düz 20 m aralık: t = 20 × sin(α). α, kuyu ile tabaka düzlemi arasındaki açıdır; zemin yüzeyiyle açı değildir. Değerler iki ondalığa yuvarlandı; saha ölçümü veya atıf yapılan yatakların tahmini değildir."},"rows":[{"label":{"ar":"30° بين الحفرة ومستوى الطبقة","en":"30° between borehole and layer plane","es":"30° entre sondeo y plano de la capa","fr":"30° entre forage et plan de la couche","pt":"30° entre furo e plano da camada","ru":"30° между стволом и плоскостью пласта","tr":"Kuyu ile tabaka düzlemi arasında 30°"},"value":10},{"label":{"ar":"45° بين الحفرة ومستوى الطبقة","en":"45° between borehole and layer plane","es":"45° entre sondeo y plano de la capa","fr":"45° entre forage et plan de la couche","pt":"45° entre furo e plano da camada","ru":"45° между стволом и плоскостью пласта","tr":"Kuyu ile tabaka düzlemi arasında 45°"},"value":14.14},{"label":{"ar":"90° بين الحفرة ومستوى الطبقة","en":"90° between borehole and layer plane","es":"90° entre sondeo y plano de la capa","fr":"90° entre forage et plan de la couche","pt":"90° entre furo e plano da camada","ru":"90° между стволом и плоскостью пласта","tr":"Kuyu ile tabaka düzlemi arasında 90°"},"value":20}],"unit":"m","title":{"ar":"السماكة العمودية الافتراضية لفاصل بطول 20 متراً على مسار الحفر","en":"Hypothetical perpendicular thickness for a 20-metre downhole interval","es":"Espesor perpendicular hipotético para un intervalo de sondeo de 20 metros","fr":"Épaisseur perpendiculaire hypothétique pour un intervalle foré de 20 mètres","pt":"Espessura perpendicular hipotética para intervalo de 20 metros no furo","ru":"Условная перпендикулярная мощность при интервале 20 метров по стволу","tr":"20 metrelik hayali kuyu içi aralık için dik kalınlık"},"unitLabel":{"ar":"متر","en":"metres","es":"metros","fr":"mètres","pt":"metros","ru":"метры","tr":"metre"}},"horizon":"Source definitions and illustrative geometry","horizonLabel":{"ar":"تعريفات المصادر وهندسة توضيحية","en":"Source definitions and illustrative geometry","es":"Definiciones de las fuentes y geometría ilustrativa","fr":"Définitions des sources et géométrie illustrative","pt":"Definições das fontes e geometria ilustrativa","ru":"Определения источников и условная геометрия","tr":"Kaynak tanımları ve örnek geometri"},"evidenceCutoff":"2026-11-05"},"classification":{"version":"1","dataKinds":["project-update"],"geographies":[{"role":"economic-scope","countryCode":"CA","subdivisionCode":null},{"role":"economic-scope","countryCode":"ES","subdivisionCode":null},{"role":"economic-scope","countryCode":"GL","subdivisionCode":null}],"evidenceBasis":["reported-observation"],"measurementPeriod":null}}},{"requestedLanguage":"en","fallback":false,"record":{"id":"refinery-capacity-calendar-stream-day-engineering-guide","canonicalSlug":"refinery-capacity-calendar-stream-day-engineering-guide","url":"https://wellficent.com/en/news/refinery-capacity-calendar-stream-day-engineering-guide","language":"en","title":"Refinery capacity: calendar day, stream day and actual throughput","summary":"An engineering guide to refinery capacity, dated project milestones and transparent calculations, with lessons from Ballymore, Kaminho and P1000.","body":["Two refineries advertised at the same barrels-per-day rate may be reporting different quantities. EIA defines calendar-day capacity as processing capability under usual conditions, including operational constraints and downtime. Stream-day capacity assumes optimal operation without downtime. Neither is a measured production series.","A credible comparison therefore needs the facility type, process, input or output basis, unit, capacity definition and reference date. Crude distillation, a gas-processing plant, a mineral refinery and an oil terminal are different facilities even if their names contain “refinery”."],"keyPoints":[],"sections":[{"heading":"Read the reference date before comparing plants","paragraphs":["EIA’s 2026 Refinery Capacity Report was released on 26 June 2026 but describes capacity as of 1 January 2026. A subsequent closure or ownership change requires its own evidence. Operating, idle and operable capacity must remain separate; the report also covers some non-refinery process operators.","Wellficent’s refinery edition 2026-11-11-r16 combines EIA records with mapped records of varying evidence quality. An OpenStreetMap tag is not an operator certification. Unverified capacity tags cannot support a worldwide ranking or a global census of operating crude refineries."]},{"heading":"A reproducible calculation, with assumptions visible","paragraphs":["Assume a fictional unit has stream-day capacity of 100,000 barrels and operates at that full rate for an assumed fraction f of a 365-day year. Annual input = 100,000 × 365 × f. At 80%, 90% and 100%, the results are 29.2, 32.85 and 36.5 million barrels respectively.","The chart shows this arithmetic only. These are not measurements from a real refinery, a forecast or EIA utilisation rates. The assumed fraction combines downtime and reduced operation into a simplified scenario; feedstock and product constraints would require a fuller model. Applying another downtime allowance to calendar-day capacity can count an allowance twice."]},{"heading":"Process capacity is not additive","paragraphs":["A hypothetical 100,000-barrel crude distillation unit plus a 30,000-barrel catalytic-cracking unit does not equal 130,000 barrels of crude intake. Downstream units process fractions from earlier units; their charge and product capacities have different scopes. Product yields, energy use and hydrogen requirements need a process balance, not addition of equipment ratings.","At Basra, South Refineries Company reports four primary refining units rated at 70,000 barrels per day each. Its fourth-unit project record dates start-up to 15 December 2023 and gives a site capacity increase from 210,000 to 280,000 b/d. The primary-train calculation is 4 × 70,000 = 280,000 b/d. It reproduces the nominal scope in the operator’s account.","JGC lists 34,500 b/d of fluid catalytic cracking (FCC), 55,000 b/d of vacuum distillation and 40,000 b/d of diesel desulfurization in the adjacent upgrade. These rates describe different process feeds. Vacuum distillation processes residue from atmospheric distillation, FCC upgrades heavier fractions and desulfurization treats diesel-range streams. Adding the three downstream rates to the primary total would give 409,500 b/d, 46.25% above the primary-train figure. That sum counts downstream charges as additional crude intake.","An annual throughput or utilisation estimate would require a dated crude-input series and a capacity denominator for the same facilities and period. The 10 November 2026 review adds this case to the guide. The linked Wellficent Basra record preserves the map capacity’s OSM provenance and treats refinery classification and operating status as distinct evidence.","The review added on 11 November 2026 provides a second documented example. National Refinery’s Karachi process description states that Lube-I starts with desalted crude, atmospheric distillation and then vacuum distillation. Lube-II starts at the vacuum stage using reduced crude supplied by the Fuel Refinery. A lubricant product slate therefore does not by itself exclude primary crude processing. The linked Refinery Atlas record identifies this same Karachi installation and retains its original map provenance.","For an engineering balance, define the complex boundary and count external crude feed once. The documented reduced-crude transfer from the Fuel Refinery to Lube-II is an internal stream. Adding primary crude-unit capacity to the receiving vacuum unit’s feed capacity would count part of the same material twice. The source describes process routing; it does not supply a complete current material balance or a comparable calendar-day versus stream-day capacity basis for this example. Those quantities remain unknown."]},{"heading":"The same discipline applies to wells and project news","paragraphs":["Ballymore’s April 2025 announcement reports 75,000 barrels of oil per day and gas capacity separately. Kaminho’s May 2024 decision gives a 2028 start-up target, rather than current output. P1000’s first ore on 31 January 2025 establishes a commissioning milestone, not sustained concentrate quality. The related reports preserve those distinctions.","Well Atlas records are also source-scoped entries, not automatically distinct physical wells. A field production total cannot be allocated to a particular well without evidence. A nearby refinery or a shared company name does not prove a supply-chain connection."]},{"heading":"Facility names are not process evidence","paragraphs":["Buckeye Hammond illustrates the terminal problem. The IRS fuel-terminal list dated 30 August 2026 identifies East Hammond at 2400 Michigan Street; the corresponding IDEM renewal notice describes the Hammond Terminal. At Long Beach, port documents identify Oxbow’s petroleum-coke storage and transfer activity at 1090 Pier G Avenue. Neither document establishes a crude distillation unit. Storage tonnage is an inventory quantity; loading capacity is a transfer rate. Neither can be substituted for a refinery’s crude-processing capacity.","The product name alone is also insufficient. MOL’s 2023 report explicitly describes Zala as a rubber-bitumen manufacturing plant without traditional refining activities; its 2025 report again identifies rubber-bitumen production there. Conversely, the Greater Gothenburg Rescue Service explicitly describes crude distillation at Nynas’s Gothenburg refinery, whose principal product is bitumen. These sites therefore require different classifications. Confirm the feed and process before deciding whether a bitumen site belongs in a crude-refinery comparison.","Status needs its own evidence. INA’s 2024 report says Sisak Refinery was permanently closed in 2020 and was undergoing conversion to another use. That does not mean every activity at the industrial site ceased. The 2025 report places the proposed Sisak Biomethane project on hold pending permitting. A former crude refinery, a conversion proposal and an operating biorefinery are three different descriptions. Retaining the historical site with a documented refining closure preserves that distinction without inventing a replacement plant.","Aramco’s Shaybah description separates the oil-field expansion from the natural-gas-liquids recovery project. It dates the field’s increase to one million barrels per day of oil production capacity to 2016 and describes an NGL recovery plant rated at 2.4 billion standard cubic feet per day. These are different process boundaries and different measured quantities. Neither figure is a crude-refinery intake rating for the mapped Shaybah field-processing record.","Samsung E&A’s Shaybah project portfolio describes four packages: gas pretreatment; NGL recovery and utilities; cogeneration; and upstream gas/oil separation. It gives completion as 2016. This process description supports the upstream/gas-processing context, but does not establish that a mapped polygon corresponds to a particular package. A contractor’s project description and a field-wide production rating cannot be combined into a new crude-distillation capacity. Each figure needs its own documented unit boundary and reference basis.","The linked Shaybah Atlas record therefore uses field/gas-processing, retains unknown operating status and has no verified crude-distillation capacity. The classification does not assign a particular project package or every field asset to the map polygon. Standard gas volume, liquid volume and mass remain separate quantities; the related API-gravity guide addresses single-liquid mass–volume arithmetic, not a conversion of standard gas flow into refinery barrels.","Harburg shows why the process boundary matters within one complex. Hamburg’s 5 September 2024 Wilhelmsburg study, page 25, assigns naphthenic crude distillation to the north works at Hohe-Schaar-Strasse 34 and further processing of heavy fractions to the south works at Moorburger Strasse 10. The European Commission’s 2013 decision separately describes the southern base-oil, blending and bitumen assets. Two mapped works therefore do not establish two independently rated crude-distillation plants. Nynas’s 2025 annual report, page 74, records the 2022 decision to cease Harburg production and ongoing dismantling. Historical process evidence and an expired certificate do not override that separately documented cessation.","YPF Química’s Ensenada description makes another distinction: a petrochemical complex receives virgin naphtha and liquefied petroleum gas from an integrated refinery. Its listed chemical-product tonnage is not crude-distillation capacity. These source reviews were added on 11 November 2026; the guide’s first publication remains unchanged. The linked Atlas records preserve their original IDs and review histories. Use the related heat-duty guide for explicitly hypothetical energy calculations; neither those calculations nor these process descriptions measure current plant efficiency or availability."]},{"heading":"Keep operator measures in their stated units","paragraphs":["Oilinvest describes Holborn’s processing capacity as around 105,000 barrels of crude per day and separately gives average throughput of 4.5 million tonnes per year. OMV describes approximately 3.8 million tonnes of crude processed annually at Burghausen. The latter wording concerns throughput. Neither statement establishes a comparable EIA calendar-day capacity. Do not turn approximate operator descriptions into more precise engineering specifications than the source supplies.","Mass-to-volume conversion requires a stated density and its reference conditions. Dividing an annual mass by an assumed density and a chosen number of days produces an assumption-dependent rate, rather than a newly reported capacity. Crude composition and temperature matter, and the appropriate calendar depends on the question. A transparent model can declare those inputs for a hypothetical case; a verified database should leave the comparable capacity unknown when they are absent. Missing capacity is not zero.","VAROPreem’s Gothenburg safety information, updated 27 May 2026, describes a crude-fed hydroskimming refinery with some sections converted to biorefining. Its six million tonnes per year remains in the source’s unit. Partial conversion does not establish that the whole refinery stopped processing crude. Nor does a dated safety description certify today’s operating rate. Keep the activity evidence, its date and the unknown measurement separate.","Maysan illustrates a reconciliation problem inside a primary source. South Refineries Company’s English and Arabic histories describe an initial 10,000 barrels/day and two additional 10,000-barrel/day units, yet state a 40,000-barrel/day total. The stated components sum to 30,000, leaving an unexplained 10,000 difference. This arithmetic flags missing context; it does not establish a corrected plant rating or an undocumented fourth unit. The Atlas retains the original 40,000-barrel/day OSM tag with OSM provenance.","Kalak also requires site matching. The Kurdistan ministry describes 80,000 barrels/day and a planned 100,000 by 2014. Its official map supports the northwest refinery, a separate Atlas record. Those sources cannot verify the southern record’s identity or 175,000-barrel/day tag; its classification remains capacity-tag. Maysan’s process identity is corroborated, while both numeric tags retain OSM provenance and unknown operating status. Names, measurements and sites need separate verification."]},{"heading":"Use the right denominator for costs and utilisation","paragraphs":["EIA defines refinery capacity utilisation using gross input to atmospheric crude distillation units divided by operable refining capacity. A product shipment series, an individual downstream unit’s feed or a stream-day design rating cannot silently replace either side. Match the reporting period, facility scope and definition before comparing two utilisation percentages. If the numerator includes additional units or the denominator describes another date, a precise-looking percentage can conceal a broken comparison. Record the mismatch rather than repairing it with an undocumented adjustment.","For a separate fictional economic sensitivity, assume the illustrative 100,000-barrel-per-stream-day unit can process one additional full-rate day. Assume USD 5 of contribution per barrel of feed after feedstock and variable operating costs, before fixed costs, financing, tax and capital expenditure. The incremental contribution is 100,000 × 1 × 5 = USD 500,000. This is arithmetic under declared assumptions, not a current refining margin, a plant profit, an avoided-maintenance bill or an investment valuation.","A real decision would need a compatible product slate, feed and product prices, incremental energy and hydrogen requirements, saleable quality, maintenance consequences and working capital. More crude feed does not guarantee the same contribution per barrel if a downstream constraint changes the yield or product specification. Cash timing and capital recovery also matter. Do not present this single operating sensitivity as a discounted cash-flow model or attach an unsupported probability to it."]},{"heading":"Make the research reproducible","paragraphs":["Keep the source-scoped facility ID, raw name and tags alongside the reviewed classification. Record the exact document URL, publication or reporting period, access date and edition in which a decision changed. An address-range geocoder can corroborate location, but does not certify a legal boundary or a company’s ownership. A geographic match alone does not prove a pipeline connection, a purchase contract or the destination of any well’s production. Use a separately documented relationship when that is the research question.","A subsequent source review on 8 November 2026 adds these examples and updates this guide to refinery edition 2026-11-08-r7; the original publication date is preserved. This is a selective review of retained source records, not a new global survey or a live operating census. The underlying EIA reference date remains 1 January 2026. Earlier classifications and corrections remain in their histories. The seven language editions share the same quantities, calculation assumptions and evidence limits."]},{"heading":"Limits and evidence needed next","paragraphs":["This guide explains definitions and arithmetic; it does not independently certify plant operation or estimate missing capacity. A decision-grade comparison needs the latest dated operator or regulator documents, compatible measurement periods and explicit uncertainty. Keep source rights and attribution when reusing records. The illustration is AI-generated and conceptual, not a photographed refinery or a process design."]}],"text":"Refinery capacity: calendar day, stream day and actual throughput\n\nAn engineering guide to refinery capacity, dated project milestones and transparent calculations, with lessons from Ballymore, Kaminho and P1000.\n\nTwo refineries advertised at the same barrels-per-day rate may be reporting different quantities. EIA defines calendar-day capacity as processing capability under usual conditions, including operational constraints and downtime. Stream-day capacity assumes optimal operation without downtime. Neither is a measured production series.\n\nA credible comparison therefore needs the facility type, process, input or output basis, unit, capacity definition and reference date. Crude distillation, a gas-processing plant, a mineral refinery and an oil terminal are different facilities even if their names contain “refinery”.\n\nRead the reference date before comparing plants\n\nEIA’s 2026 Refinery Capacity Report was released on 26 June 2026 but describes capacity as of 1 January 2026. A subsequent closure or ownership change requires its own evidence. Operating, idle and operable capacity must remain separate; the report also covers some non-refinery process operators.\n\nWellficent’s refinery edition 2026-11-11-r16 combines EIA records with mapped records of varying evidence quality. An OpenStreetMap tag is not an operator certification. Unverified capacity tags cannot support a worldwide ranking or a global census of operating crude refineries.\n\nA reproducible calculation, with assumptions visible\n\nAssume a fictional unit has stream-day capacity of 100,000 barrels and operates at that full rate for an assumed fraction f of a 365-day year. Annual input = 100,000 × 365 × f. At 80%, 90% and 100%, the results are 29.2, 32.85 and 36.5 million barrels respectively.\n\nThe chart shows this arithmetic only. These are not measurements from a real refinery, a forecast or EIA utilisation rates. The assumed fraction combines downtime and reduced operation into a simplified scenario; feedstock and product constraints would require a fuller model. Applying another downtime allowance to calendar-day capacity can count an allowance twice.\n\nProcess capacity is not additive\n\nA hypothetical 100,000-barrel crude distillation unit plus a 30,000-barrel catalytic-cracking unit does not equal 130,000 barrels of crude intake. Downstream units process fractions from earlier units; their charge and product capacities have different scopes. Product yields, energy use and hydrogen requirements need a process balance, not addition of equipment ratings.\n\nAt Basra, South Refineries Company reports four primary refining units rated at 70,000 barrels per day each. Its fourth-unit project record dates start-up to 15 December 2023 and gives a site capacity increase from 210,000 to 280,000 b/d. The primary-train calculation is 4 × 70,000 = 280,000 b/d. It reproduces the nominal scope in the operator’s account.\n\nJGC lists 34,500 b/d of fluid catalytic cracking (FCC), 55,000 b/d of vacuum distillation and 40,000 b/d of diesel desulfurization in the adjacent upgrade. These rates describe different process feeds. Vacuum distillation processes residue from atmospheric distillation, FCC upgrades heavier fractions and desulfurization treats diesel-range streams. Adding the three downstream rates to the primary total would give 409,500 b/d, 46.25% above the primary-train figure. That sum counts downstream charges as additional crude intake.\n\nAn annual throughput or utilisation estimate would require a dated crude-input series and a capacity denominator for the same facilities and period. The 10 November 2026 review adds this case to the guide. The linked Wellficent Basra record preserves the map capacity’s OSM provenance and treats refinery classification and operating status as distinct evidence.\n\nThe review added on 11 November 2026 provides a second documented example. National Refinery’s Karachi process description states that Lube-I starts with desalted crude, atmospheric distillation and then vacuum distillation. Lube-II starts at the vacuum stage using reduced crude supplied by the Fuel Refinery. A lubricant product slate therefore does not by itself exclude primary crude processing. The linked Refinery Atlas record identifies this same Karachi installation and retains its original map provenance.\n\nFor an engineering balance, define the complex boundary and count external crude feed once. The documented reduced-crude transfer from the Fuel Refinery to Lube-II is an internal stream. Adding primary crude-unit capacity to the receiving vacuum unit’s feed capacity would count part of the same material twice. The source describes process routing; it does not supply a complete current material balance or a comparable calendar-day versus stream-day capacity basis for this example. Those quantities remain unknown.\n\nThe same discipline applies to wells and project news\n\nBallymore’s April 2025 announcement reports 75,000 barrels of oil per day and gas capacity separately. Kaminho’s May 2024 decision gives a 2028 start-up target, rather than current output. P1000’s first ore on 31 January 2025 establishes a commissioning milestone, not sustained concentrate quality. The related reports preserve those distinctions.\n\nWell Atlas records are also source-scoped entries, not automatically distinct physical wells. A field production total cannot be allocated to a particular well without evidence. A nearby refinery or a shared company name does not prove a supply-chain connection.\n\nFacility names are not process evidence\n\nBuckeye Hammond illustrates the terminal problem. The IRS fuel-terminal list dated 30 August 2026 identifies East Hammond at 2400 Michigan Street; the corresponding IDEM renewal notice describes the Hammond Terminal. At Long Beach, port documents identify Oxbow’s petroleum-coke storage and transfer activity at 1090 Pier G Avenue. Neither document establishes a crude distillation unit. Storage tonnage is an inventory quantity; loading capacity is a transfer rate. Neither can be substituted for a refinery’s crude-processing capacity.\n\nThe product name alone is also insufficient. MOL’s 2023 report explicitly describes Zala as a rubber-bitumen manufacturing plant without traditional refining activities; its 2025 report again identifies rubber-bitumen production there. Conversely, the Greater Gothenburg Rescue Service explicitly describes crude distillation at Nynas’s Gothenburg refinery, whose principal product is bitumen. These sites therefore require different classifications. Confirm the feed and process before deciding whether a bitumen site belongs in a crude-refinery comparison.\n\nStatus needs its own evidence. INA’s 2024 report says Sisak Refinery was permanently closed in 2020 and was undergoing conversion to another use. That does not mean every activity at the industrial site ceased. The 2025 report places the proposed Sisak Biomethane project on hold pending permitting. A former crude refinery, a conversion proposal and an operating biorefinery are three different descriptions. Retaining the historical site with a documented refining closure preserves that distinction without inventing a replacement plant.\n\nAramco’s Shaybah description separates the oil-field expansion from the natural-gas-liquids recovery project. It dates the field’s increase to one million barrels per day of oil production capacity to 2016 and describes an NGL recovery plant rated at 2.4 billion standard cubic feet per day. These are different process boundaries and different measured quantities. Neither figure is a crude-refinery intake rating for the mapped Shaybah field-processing record.\n\nSamsung E&A’s Shaybah project portfolio describes four packages: gas pretreatment; NGL recovery and utilities; cogeneration; and upstream gas/oil separation. It gives completion as 2016. This process description supports the upstream/gas-processing context, but does not establish that a mapped polygon corresponds to a particular package. A contractor’s project description and a field-wide production rating cannot be combined into a new crude-distillation capacity. Each figure needs its own documented unit boundary and reference basis.\n\nThe linked Shaybah Atlas record therefore uses field/gas-processing, retains unknown operating status and has no verified crude-distillation capacity. The classification does not assign a particular project package or every field asset to the map polygon. Standard gas volume, liquid volume and mass remain separate quantities; the related API-gravity guide addresses single-liquid mass–volume arithmetic, not a conversion of standard gas flow into refinery barrels.\n\nHarburg shows why the process boundary matters within one complex. Hamburg’s 5 September 2024 Wilhelmsburg study, page 25, assigns naphthenic crude distillation to the north works at Hohe-Schaar-Strasse 34 and further processing of heavy fractions to the south works at Moorburger Strasse 10. The European Commission’s 2013 decision separately describes the southern base-oil, blending and bitumen assets. Two mapped works therefore do not establish two independently rated crude-distillation plants. Nynas’s 2025 annual report, page 74, records the 2022 decision to cease Harburg production and ongoing dismantling. Historical process evidence and an expired certificate do not override that separately documented cessation.\n\nYPF Química’s Ensenada description makes another distinction: a petrochemical complex receives virgin naphtha and liquefied petroleum gas from an integrated refinery. Its listed chemical-product tonnage is not crude-distillation capacity. These source reviews were added on 11 November 2026; the guide’s first publication remains unchanged. The linked Atlas records preserve their original IDs and review histories. Use the related heat-duty guide for explicitly hypothetical energy calculations; neither those calculations nor these process descriptions measure current plant efficiency or availability.\n\nKeep operator measures in their stated units\n\nOilinvest describes Holborn’s processing capacity as around 105,000 barrels of crude per day and separately gives average throughput of 4.5 million tonnes per year. OMV describes approximately 3.8 million tonnes of crude processed annually at Burghausen. The latter wording concerns throughput. Neither statement establishes a comparable EIA calendar-day capacity. Do not turn approximate operator descriptions into more precise engineering specifications than the source supplies.\n\nMass-to-volume conversion requires a stated density and its reference conditions. Dividing an annual mass by an assumed density and a chosen number of days produces an assumption-dependent rate, rather than a newly reported capacity. Crude composition and temperature matter, and the appropriate calendar depends on the question. A transparent model can declare those inputs for a hypothetical case; a verified database should leave the comparable capacity unknown when they are absent. Missing capacity is not zero.\n\nVAROPreem’s Gothenburg safety information, updated 27 May 2026, describes a crude-fed hydroskimming refinery with some sections converted to biorefining. Its six million tonnes per year remains in the source’s unit. Partial conversion does not establish that the whole refinery stopped processing crude. Nor does a dated safety description certify today’s operating rate. Keep the activity evidence, its date and the unknown measurement separate.\n\nMaysan illustrates a reconciliation problem inside a primary source. South Refineries Company’s English and Arabic histories describe an initial 10,000 barrels/day and two additional 10,000-barrel/day units, yet state a 40,000-barrel/day total. The stated components sum to 30,000, leaving an unexplained 10,000 difference. This arithmetic flags missing context; it does not establish a corrected plant rating or an undocumented fourth unit. The Atlas retains the original 40,000-barrel/day OSM tag with OSM provenance.\n\nKalak also requires site matching. The Kurdistan ministry describes 80,000 barrels/day and a planned 100,000 by 2014. Its official map supports the northwest refinery, a separate Atlas record. Those sources cannot verify the southern record’s identity or 175,000-barrel/day tag; its classification remains capacity-tag. Maysan’s process identity is corroborated, while both numeric tags retain OSM provenance and unknown operating status. Names, measurements and sites need separate verification.\n\nUse the right denominator for costs and utilisation\n\nEIA defines refinery capacity utilisation using gross input to atmospheric crude distillation units divided by operable refining capacity. A product shipment series, an individual downstream unit’s feed or a stream-day design rating cannot silently replace either side. Match the reporting period, facility scope and definition before comparing two utilisation percentages. If the numerator includes additional units or the denominator describes another date, a precise-looking percentage can conceal a broken comparison. Record the mismatch rather than repairing it with an undocumented adjustment.\n\nFor a separate fictional economic sensitivity, assume the illustrative 100,000-barrel-per-stream-day unit can process one additional full-rate day. Assume USD 5 of contribution per barrel of feed after feedstock and variable operating costs, before fixed costs, financing, tax and capital expenditure. The incremental contribution is 100,000 × 1 × 5 = USD 500,000. This is arithmetic under declared assumptions, not a current refining margin, a plant profit, an avoided-maintenance bill or an investment valuation.\n\nA real decision would need a compatible product slate, feed and product prices, incremental energy and hydrogen requirements, saleable quality, maintenance consequences and working capital. More crude feed does not guarantee the same contribution per barrel if a downstream constraint changes the yield or product specification. Cash timing and capital recovery also matter. Do not present this single operating sensitivity as a discounted cash-flow model or attach an unsupported probability to it.\n\nMake the research reproducible\n\nKeep the source-scoped facility ID, raw name and tags alongside the reviewed classification. Record the exact document URL, publication or reporting period, access date and edition in which a decision changed. An address-range geocoder can corroborate location, but does not certify a legal boundary or a company’s ownership. A geographic match alone does not prove a pipeline connection, a purchase contract or the destination of any well’s production. Use a separately documented relationship when that is the research question.\n\nA subsequent source review on 8 November 2026 adds these examples and updates this guide to refinery edition 2026-11-08-r7; the original publication date is preserved. This is a selective review of retained source records, not a new global survey or a live operating census. The underlying EIA reference date remains 1 January 2026. Earlier classifications and corrections remain in their histories. The seven language editions share the same quantities, calculation assumptions and evidence limits.\n\nLimits and evidence needed next\n\nThis guide explains definitions and arithmetic; it does not independently certify plant operation or estimate missing capacity. A decision-grade comparison needs the latest dated operator or regulator documents, compatible measurement periods and explicit uncertainty. Keep source rights and attribution when reusing records. The illustration is AI-generated and conceptual, not a photographed refinery or a process design.\n\nTechnical and economic analysis\n\nAnalysis as of: 2026-11-11\n\nEvidence cutoff: 2026-11-11\n\nOutlook horizon: Definitions and illustrative annual arithmetic\n\nIllustrative sensitivity\n\nIllustrative annual feed at assumed operating fractions\n\nFictional 100,000 b/sd unit; annual input = 100,000 × 365 × assumed fraction. Not an EIA utilisation calculation, plant observation or forecast.\n\nThese calculations illustrate stated assumptions; they are not observations or a calibrated forecast.\n\n80% assumed operating fraction: 29.2 million barrels of feed\n\n90% assumed operating fraction: 32.85 million barrels of feed\n\n100% assumed operating fraction: 36.5 million barrels of feed","category":"energy","region":"world","topics":["oil","gas","mining"],"eventDate":"2026-11-11","eventDateBasis":"analysis-as-of-date","publishedAt":"2026-11-05T21:08:29Z","modifiedAt":"2026-11-11T16:33:47Z","publicationBasis":"first-publication","preparedAt":"2026-11-05T21:05:22Z","sourcePublishedAt":null,"translatedAt":null,"sources":[{"url":"https://www.eia.gov/tools/glossary/index.php?id=B","name":"U.S. EIA — capacity definitions","licence":"U.S. government public domain","checkedAt":"2026-11-08","licenseUrl":"https://www.eia.gov/about/copyrights_reuse.php","attribution":"U.S. Energy Information Administration"},{"url":"https://www.eia.gov/petroleum/refinerycapacity/index.php","name":"U.S. EIA — Refinery Capacity Report 2026","checkedAt":"2026-11-08","publishedAt":"2026-06-26"},{"url":"https://www.eia.gov/energyexplained/oil-and-petroleum-products/refining-crude-oil.php","name":"U.S. EIA — refining crude oil","checkedAt":"2026-11-08"},{"url":"https://wellficent.com/api/v1/refineries","name":"Wellficent — refinery edition and source metadata","checkedAt":"2026-11-08"},{"url":"https://totalenergies.com/newsroom/united-states-first-oil-ballymore-offshore-field/?lang=eng","name":"TotalEnergies — Ballymore first production","checkedAt":"2026-11-08","publishedAt":"2025-04-21"},{"url":"https://totalenergies.com/newsroom/angola-totalenergies-launches-kaminho-deepwater-project/?lang=eng","name":"TotalEnergies — Kaminho investment decision","checkedAt":"2026-11-08","publishedAt":"2024-05-21"},{"url":"https://www.pls.com/news/p1000-achieves-first-ore","name":"PLS — P1000 achieves first ore","checkedAt":"2026-11-08","publishedAt":"2025-01-31"},{"url":"https://www.eia.gov/tools/glossary/index.php?id=R","name":"U.S. EIA — refinery capacity utilisation definition","checkedAt":"2026-11-08"},{"url":"https://www.eitc.irs.gov/pub/irs-sbse/tcn-db.pdf","name":"IRS — Active Fuel Terminals, 30 August 2026","checkedAt":"2026-11-08"},{"url":"https://www.in.gov/idem/files/notice_20260211_air_49296pn-cm.pdf","name":"IDEM — Hammond Terminal renewal notice T 089-49296-00239","checkedAt":"2026-11-08"},{"url":"https://longbeach.legistar.com/View.ashx?GUID=552807C6-752D-46F8-A37E-5FAB28FA2636&ID=3213108&M=F","name":"Port of Long Beach — Oxbow coke storage permit and site plans, PDF pp. 10, 25–29","checkedAt":"2026-11-08"},{"url":"https://ceqanet.lci.ca.gov/2025030444","name":"Port of Long Beach — existing Valero Barn improvements, SCH 2025030444","checkedAt":"2026-11-08"},{"url":"https://molgroup.info/storage/documents/publications/annual_reports/2023/integrated-annual-report-2023-eng.pdf","name":"MOL — Integrated Annual Report 2023, p. 161","checkedAt":"2026-11-08"},{"url":"https://www.bse.hu/newkibdata/129436921/MOL_2025_Integrated%20Annual%20report_ENG.pdf","name":"MOL — Integrated Annual Report 2025, p. 92","checkedAt":"2026-11-08"},{"url":"https://www.ina.hr/app/uploads/2025/04/INA-Annual-report-2024-ENG-2.pdf","name":"INA — Annual Report 2024, p. 202","checkedAt":"2026-11-08"},{"url":"https://www.ina.hr/app/uploads/2026/04/INA-Annual-Report-2025.pdf","name":"INA — Annual Report 2025, p. 47","checkedAt":"2026-11-08"},{"url":"https://www.oilinvest.com/what-we-do/operations/holborn-refinery/","name":"Oilinvest — Holborn refinery","checkedAt":"2026-11-08"},{"url":"https://www.omv.de/de/unternehmen/raffinerie-burghausen","name":"OMV — Burghausen refinery","checkedAt":"2026-11-08"},{"url":"https://www.preem.com/information-allmanheten/information-allmanheten-raffinaderiet-goteborg/information-sevesodirektivet-varopreems-raffinaderi-goteborg/","name":"VAROPreem — Gothenburg Seveso information, updated 27 May 2026","checkedAt":"2026-11-08"},{"url":"https://www.rsgbg.se/foretag--organisation/seveso-anlaggningar/goteborg/nynas-ab-goteborg/","name":"Greater Gothenburg Rescue Service — Nynas Gothenburg, updated 26 November 2025","checkedAt":"2026-11-08"},{"url":"https://src.gov.iq/news-detail.aspx?id=+15","name":"South Refineries Company — Basra fourth refining unit","checkedAt":"2026-11-10","publishedAt":"2024-09-21"},{"url":"https://www.jgc.com/en/projects/075.html","name":"JGC — Basra refinery upgrading project and process capacities","checkedAt":"2026-11-10"},{"url":"https://wellficent.com/en/refineries/osm-way-203574525","name":"Wellficent — Basra refinery record","checkedAt":"2026-11-10"},{"url":"https://nrlpak.com/production","name":"National Refinery — Karachi lube and fuel process descriptions","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-245548500","name":"Wellficent Refinery Atlas — National Refinery Karachi record","checkedAt":"2026-11-11"},{"url":"https://www.aramco.com/en/who-we-are/mega-projects/shaybah","name":"Aramco — Shaybah field expansion and NGL recovery scope","checkedAt":"2026-11-11"},{"url":"https://sea.samsungena.com/en/business/project-template?idx=44","name":"Samsung E&A — Shaybah NGL project packages and completion","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-590280338","name":"Wellficent Atlas — Shaybah field/gas-processing record","checkedAt":"2026-11-11"},{"url":"https://src.gov.iq/en/about.aspx","name":"South Refineries Company — Maysan unit history, English","checkedAt":"2026-11-11"},{"url":"https://src.gov.iq/about.aspx","name":"South Refineries Company — Maysan unit history, Arabic","checkedAt":"2026-11-11"},{"url":"https://gov.krd/mnr-en/publications/downstream/","name":"Kurdistan Ministry of Natural Resources — historical Kalak capacity and expansion targets","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-1449918496","name":"Wellficent Atlas — Maysan classification and OSM capacity provenance","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-1396234178","name":"Wellficent Atlas — southern Kalak-named record, unresolved identity and OSM capacity tag","checkedAt":"2026-11-11"},{"url":"https://archive.gov.krd/mnr/mnr.krg.org/images/pdfs/Licences_and_energy_infrastructure_TOGY_2013_1.pdf","name":"Kurdistan Ministry — 2013 infrastructure map distinguishing northwest Kalak from southern sites","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-269474988","name":"Wellficent Atlas — separately documented northwest Kalak record","checkedAt":"2026-11-11"},{"url":"https://daten.transparenz.hamburg.de/Dataport.HmbTG.ZS.Webservice.GetRessource100/GetRessource100.svc/1f959f1e-3e49-4e1c-8fa3-448d68287d87/Akte__000.00-04.pdf","name":"Hamburg authorities — Wilhelmsburg 100, 5 September 2024, p.25, north/south process scopes","checkedAt":"2026-11-11"},{"url":"https://ec.europa.eu/competition/mergers/cases/decisions/m6360_5463_2.pdf","name":"European Commission — 2 September 2013 Harburg decision, paras.4,6,10–11","checkedAt":"2026-11-11"},{"url":"https://www.nynas.com/globalassets/about-us/financials/nynas-annual-and-sustainability-report-2025-final.pdf","name":"Nynas — 2025 annual report, p.74, documented cessation and dismantling","checkedAt":"2026-11-11"},{"url":"https://quimica.ypf.com/","name":"YPF Quimica — Complejos Industriales, Ensenada petrochemical scope","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-relation-8738090","name":"Wellficent Atlas — retained Harburg North record","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-relation-9807678","name":"Wellficent Atlas — retained Harburg South base-oil record","checkedAt":"2026-11-11"},{"url":"https://wellficent.com/en/refineries/osm-way-192837459","name":"Wellficent Atlas — retained Ensenada petrochemical record","checkedAt":"2026-11-11"}],"translations":{"en":"https://wellficent.com/en/news/refinery-capacity-calendar-stream-day-engineering-guide","tr":"https://wellficent.com/tr/news/refinery-capacity-calendar-stream-day-engineering-guide","ar":"https://wellficent.com/ar/news/refinery-capacity-calendar-stream-day-engineering-guide","fr":"https://wellficent.com/fr/news/refinery-capacity-calendar-stream-day-engineering-guide","es":"https://wellficent.com/es/news/refinery-capacity-calendar-stream-day-engineering-guide","ru":"https://wellficent.com/ru/news/refinery-capacity-calendar-stream-day-engineering-guide","pt":"https://wellficent.com/pt/news/refinery-capacity-calendar-stream-day-engineering-guide"},"corrections":[{"at":"2026-11-08T12:37:04Z","language":"en","text":"Expanded the capacity guide with eight primary-source facility reviews, explicit utilisation and hypothetical operating-economics assumptions, source/edition provenance and related engineering reading. Added reviewed conceptual AI artwork and the 8 November review context; preserved the first publication date and original calculation values."},{"at":"2026-11-08T12:48:37Z","language":"en","text":"Aligned the displayed analysis date with the documented 8 November 2026 review and analysis.asOf value. The earlier update had retained 5 November in the separate eventDate field. The first publication date, source dates, calculations and previous correction remain unchanged."},{"at":"2026-11-10T23:34:48Z","language":"en","text":"Added a Basra engineering case with the operator’s primary-unit capacity, the contractor’s downstream-unit ratings and a link to the refinery record. Aligned the analysis date with the 10 November source review."},{"at":"2026-11-11T08:44:58Z","language":"en","text":"Added a source-verified Karachi example distinguishing fresh crude processing from the documented internal reduced-crude transfer. Linked the primary process description and the exact refinery record; retained the first publication date and existing calculations."},{"at":"2026-11-11T10:53:31Z","language":"en","text":"Added a primary-source Shaybah engineering case distinguishing field oil capacity, NGL gas throughput and EPC package boundaries, with a direct Atlas record and API-density reading link. Updated the reviewed dataset edition; preserved first publication, existing calculations and correction history."},{"at":"2026-11-11T14:39:24Z","language":"en","text":"Add sourced Maysan arithmetic reconciliation and Kalak site/vintage limits in seven languages, with primary sources and direct Atlas records; preserve OSM numeric provenance, unresolved southern Kalak identity, calculations, illustration and first publication."},{"at":"2026-11-11T16:33:47Z","language":"en","text":"Add primary-source Harburg north/south process distinctions and separately documented production cessation, the Ensenada petrochemical example, direct Atlas references and related heat-duty research; preserve earlier text, calculations, correction history and first publication."}],"locations":[],"type":"analysis","analysis":{"asOf":"2026-11-11","kind":"technical-economic","chart":{"kind":"illustrative","note":{"ar":"وحدة خيالية بطاقة 100,000 برميل لكل يوم تشغيل؛ المدخل السنوي = 100,000 × 365 × النسبة المفترضة. ليست حساب استخدام EIA أو قياس مصنع أو توقعاً.","en":"Fictional 100,000 b/sd unit; annual input = 100,000 × 365 × assumed fraction. Not an EIA utilisation calculation, plant observation or forecast.","es":"Unidad ficticia de 100.000 b/d de operación; entrada anual = 100.000 × 365 × fracción supuesta. No es utilización EIA, observación ni pronóstico.","fr":"Unité fictive de 100 000 b/j de marche; entrée annuelle = 100 000 × 365 × fraction supposée. Ni taux EIA, ni observation, ni prévision.","pt":"Unidade fictícia de 100.000 b/d de operação; entrada anual = 100.000 × 365 × fração suposta. Não é utilização EIA, observação ou previsão.","ru":"Вымышленная установка 100 000 баррелей за сутки работы; годовой вход = 100 000 × 365 × доля. Не расчёт использования EIA, наблюдение или прогноз.","tr":"Hayali 100.000 b/sd ünite; yıllık giriş = 100.000 × 365 × varsayılan oran. EIA kullanım oranı hesabı, tesis gözlemi veya öngörü değildir."},"rows":[{"label":{"ar":"نسبة تشغيل مفترضة 80%","en":"80% assumed operating fraction","es":"Fracción supuesta del 80%","fr":"Fraction supposée de 80%","pt":"Fração suposta de 80%","ru":"Условная доля работы 80%","tr":"Varsayılan %80 çalışma"},"value":29.2},{"label":{"ar":"نسبة تشغيل مفترضة 90%","en":"90% assumed operating fraction","es":"Fracción supuesta del 90%","fr":"Fraction supposée de 90%","pt":"Fração suposta de 90%","ru":"Условная доля работы 90%","tr":"Varsayılan %90 çalışma"},"value":32.85},{"label":{"ar":"نسبة تشغيل مفترضة 100%","en":"100% assumed operating fraction","es":"Fracción supuesta del 100%","fr":"Fraction supposée de 100%","pt":"Fração suposta de 100%","ru":"Условная доля работы 100%","tr":"Varsayılan %100 çalışma"},"value":36.5}],"unit":"million barrels of feed","title":{"ar":"تغذية سنوية توضيحية حسب نسب تشغيل مفترضة","en":"Illustrative annual feed at assumed operating fractions","es":"Alimentación anual ilustrativa por fracción de operación","fr":"Charge annuelle illustrative selon la fraction de marche","pt":"Alimentação anual ilustrativa por fração de operação","ru":"Условная годовая загрузка при заданной доле работы","tr":"Varsayılan çalışma oranlarına göre örnek yıllık besleme"},"unitLabel":{"ar":"مليون برميل تغذية","en":"million barrels of feed","es":"millones de barriles de alimentación","fr":"millions de barils de charge","pt":"milhões de barris de alimentação","ru":"млн баррелей сырья","tr":"milyon varil besleme"}},"horizon":"Definitions and illustrative annual arithmetic","horizonLabel":{"ar":"تعريفات وحساب سنوي توضيحي","en":"Definitions and illustrative annual arithmetic","es":"Definiciones y cálculo anual ilustrativo","fr":"Définitions et calcul annuel illustratif","pt":"Definições e cálculo anual ilustrativo","ru":"Определения и иллюстративный годовой расчёт","tr":"Tanımlar ve örnek yıllık hesap"},"evidenceCutoff":"2026-11-11"},"classification":{"version":"1","dataKinds":["resource-register","project-update"],"geographies":[{"role":"economic-scope","countryCode":"US","subdivisionCode":null},{"role":"economic-scope","countryCode":"AO","subdivisionCode":null},{"role":"economic-scope","countryCode":"AU","subdivisionCode":null},{"role":"economic-scope","countryCode":"IQ","subdivisionCode":null}],"evidenceBasis":["reported-observation","plan"],"measurementPeriod":null},"relatedArticles":[{"canonicalSlug":"chevron-ballymore-deepwater-gulf-of-mexico-oil-production-nov2026","url":"https://wellficent.com/en/news/chevron-ballymore-deepwater-gulf-of-mexico-oil-production-nov2026","title":"Ballymore first production: the April 2025 milestone and Blind Faith tieback","language":"en"},{"canonicalSlug":"sonangol-totalenergies-cameia-golfinho-kwanza-basin-fid-nov2026","url":"https://wellficent.com/en/news/sonangol-totalenergies-cameia-golfinho-kwanza-basin-fid-nov2026","title":"Kaminho: the 2024 investment decision, 2028 target and gas-reinjection design","language":"en"},{"canonicalSlug":"pilbara-minerals-pilgangoora-p1000-expansion-commissioning-nov2026","url":"https://wellficent.com/en/news/pilbara-minerals-pilgangoora-p1000-expansion-commissioning-nov2026","title":"P1000 at Pilgangoora: first ore was achieved on 31 January 2025","language":"en"},{"canonicalSlug":"oil-gas-production-data-rates-boe-decline-engineering-guide","url":"https://wellficent.com/en/news/oil-gas-production-data-rates-boe-decline-engineering-guide","title":"Oil and gas production data: rates, boe, decline and value","language":"en"},{"canonicalSlug":"api-gravity-density-mass-volume-engineering-guide","url":"https://wellficent.com/en/news/api-gravity-density-mass-volume-engineering-guide","title":"API Gravity, Density and Mass–Volume Conversion: A Petroleum Engineering Guide","language":"en"},{"canonicalSlug":"refinery-mass-balance-processing-gain-engineering-guide","url":"https://wellficent.com/en/news/refinery-mass-balance-processing-gain-engineering-guide","title":"Refinery Mass Balance and Processing Gain: Why More Volume Does Not Mean More Mass","language":"en"},{"canonicalSlug":"refinery-heat-duty-fuel-efficiency-energy-intensity-engineering-guide","url":"https://wellficent.com/en/news/refinery-heat-duty-fuel-efficiency-energy-intensity-engineering-guide","title":"Refinery Heat Duty, Fuel Efficiency and Energy Intensity: An Engineering Guide","language":"en"}],"image":{"url":"https://wellficent.com/media/5a4551594bb52fc93ce2f27d91c6477f9fbfa55c49bba026e30ebae4496fb855.webp","width":1672,"height":941,"alt":"Conceptual crude refinery illustration with distillation columns, pipe racks and storage tanks; no actual site or capacity is depicted.","credit":"Wellficent / OpenAI — AI-generated conceptual illustration; not a photograph, actual facility representation or engineering evidence.","licenseUrl":"https://openai.com/policies/terms-of-use/"}}},{"requestedLanguage":"en","fallback":false,"record":{"id":"sonangol-totalenergies-cameia-golfinho-kwanza-basin-fid-nov2026","canonicalSlug":"sonangol-totalenergies-cameia-golfinho-kwanza-basin-fid-nov2026","url":"https://wellficent.com/en/news/sonangol-totalenergies-cameia-golfinho-kwanza-basin-fid-nov2026","language":"en","title":"Kaminho: the 2024 investment decision, 2028 target and gas-reinjection design","summary":"Kaminho develops Cameia and Golfinho. The verified plan uses an all-electric FPSO and reservoir reinjection of associated gas.","body":["TotalEnergies announced the final investment decision for Kaminho on 21 May 2024. The development covers Cameia and Golfinho in Angola’s Block 20/11. At that decision, TotalEnergies was operator with 40%, alongside PETRONAS with 40% and Sonangol with 20%. ANPG is the national concessionaire; Sonangol is a project partner.","The operator’s announcement places the fields about 100 kilometres offshore in water 1,700 metres deep. Its development concept converts a very large crude carrier into a floating production, storage and offloading unit connected to a subsea network. The FPSO is designed to be all-electric and to reinject associated gas into the reservoirs, avoiding routine flaring.","The May 2024 release targets production start-up in 2028 and an oil plateau of 70,000 barrels per day. These are dated project targets, not evidence of current production or a new November 2026 investment decision. A later schedule change would require a new primary source.","SLB announced on 3 July 2024 a OneSubsea contract covering a 13-well subsea production system, associated equipment and services. The release describes two development phases for Cameia and Golfinho. This is a contracted system scope, not a count of wells already producing.","Engineering interpretation: electric drive architecture does not by itself establish the electricity source or zero emissions. Reinjection requires a gas-handling and reservoir-management design. The previous claim of gas export to Angola LNG, a 150-million-cubic-foot daily gas capacity and specific permeability and sensor claims were unsupported and have been removed."],"keyPoints":[],"sections":[],"text":"Kaminho: the 2024 investment decision, 2028 target and gas-reinjection design\n\nKaminho develops Cameia and Golfinho. The verified plan uses an all-electric FPSO and reservoir reinjection of associated gas.\n\nTotalEnergies announced the final investment decision for Kaminho on 21 May 2024. The development covers Cameia and Golfinho in Angola’s Block 20/11. At that decision, TotalEnergies was operator with 40%, alongside PETRONAS with 40% and Sonangol with 20%. ANPG is the national concessionaire; Sonangol is a project partner.\n\nThe operator’s announcement places the fields about 100 kilometres offshore in water 1,700 metres deep. Its development concept converts a very large crude carrier into a floating production, storage and offloading unit connected to a subsea network. The FPSO is designed to be all-electric and to reinject associated gas into the reservoirs, avoiding routine flaring.\n\nThe May 2024 release targets production start-up in 2028 and an oil plateau of 70,000 barrels per day. These are dated project targets, not evidence of current production or a new November 2026 investment decision. A later schedule change would require a new primary source.\n\nSLB announced on 3 July 2024 a OneSubsea contract covering a 13-well subsea production system, associated equipment and services. The release describes two development phases for Cameia and Golfinho. This is a contracted system scope, not a count of wells already producing.\n\nEngineering interpretation: electric drive architecture does not by itself establish the electricity source or zero emissions. Reinjection requires a gas-handling and reservoir-management design. The previous claim of gas export to Angola LNG, a 150-million-cubic-foot daily gas capacity and specific permeability and sensor claims were unsupported and have been removed.","category":"energy","region":"world","topics":["oil","gas"],"eventDate":"2024-05-21","eventDateBasis":"source-event-or-period","publishedAt":"2026-11-02T17:32:33Z","modifiedAt":"2026-11-08T11:03:14Z","publicationBasis":"first-publication","preparedAt":null,"sourcePublishedAt":"2024-05-21","translatedAt":null,"sources":[{"url":"https://totalenergies.com/newsroom/angola-totalenergies-launches-kaminho-deepwater-project/?lang=eng","name":"TotalEnergies — Kaminho final investment decision","checkedAt":"2026-11-08","publishedAt":"2024-05-21"},{"url":"https://www.slb.com/newsroom/press-release/2024/slb-onesubsea-awarded-contract-for-totalenergies%E2%80%99-kaminho-deepwater-project","name":"SLB — OneSubsea Kaminho contract","checkedAt":"2026-11-08","publishedAt":"2024-07-03"}],"translations":{"en":"https://wellficent.com/en/news/sonangol-totalenergies-cameia-golfinho-kwanza-basin-fid-nov2026","tr":"https://wellficent.com/tr/news/sonangol-totalenergies-cameia-golfinho-kwanza-basin-fid-nov2026","ar":"https://wellficent.com/ar/news/sonangol-totalenergies-cameia-golfinho-kwanza-basin-fid-nov2026","fr":"https://wellficent.com/fr/news/sonangol-totalenergies-cameia-golfinho-kwanza-basin-fid-nov2026","es":"https://wellficent.com/es/news/sonangol-totalenergies-cameia-golfinho-kwanza-basin-fid-nov2026","ru":"https://wellficent.com/ru/news/sonangol-totalenergies-cameia-golfinho-kwanza-basin-fid-nov2026","pt":"https://wellficent.com/pt/news/sonangol-totalenergies-cameia-golfinho-kwanza-basin-fid-nov2026"},"corrections":[{"at":"2026-11-05T21:08:29Z","language":"en","text":"Rechecked primary announcements and corrected source links, dated project milestones, conditional transaction status and the scope and units of technical quantities. Removed unsupported engineering specifications and aligned all seven editions. Added documented related reading and explicitly labelled conceptual illustrations where used. Original publication dates and correction histories are preserved."},{"at":"2026-11-08T11:03:14Z","language":"en","text":"Rechecked dated primary sources and added selected engineering reading or explicitly labelled AI conceptual artwork, as applicable. InPlay’s Q3 2026 observation period, corporate-results classification and separate outlook are now structured metadata. Historical milestones, the later-evidence explanation, first publication dates and previous corrections are preserved; no physical supply or well-allocation relationship is asserted."}],"locations":[],"type":"news","classification":{"version":"1","dataKinds":["project-update","contract-award"],"geographies":[{"role":"economic-scope","countryCode":"AO","subdivisionCode":null}],"evidenceBasis":["agreement","plan"],"measurementPeriod":null},"relatedArticles":[{"canonicalSlug":"refinery-capacity-calendar-stream-day-engineering-guide","url":"https://wellficent.com/en/news/refinery-capacity-calendar-stream-day-engineering-guide","title":"Refinery capacity: calendar day, stream day and actual throughput","language":"en"},{"canonicalSlug":"oil-gas-production-data-rates-boe-decline-engineering-guide","url":"https://wellficent.com/en/news/oil-gas-production-data-rates-boe-decline-engineering-guide","title":"Oil and gas production data: rates, boe, decline and value","language":"en"}],"image":{"url":"https://wellficent.com/media/29b6908e8461bf3616ed9f7dbf62260bb4e51cdf61a835798ee3c0cea6e03dd6.webp","width":1672,"height":941,"alt":"Conceptual illustration of an FPSO with process modules and subsea risers; not the actual Kaminho vessel or design.","credit":"Wellficent / OpenAI — AI-generated conceptual illustration; not a photograph, actual facility representation or engineering evidence.","licenseUrl":"https://openai.com/policies/terms-of-use/"}}}],"semantics":["Exact server-rendered editorial collection selection, order and 12-card page. The independent news feed retains its own 20-item, real-edition-only contract.","Default editorial collections exclude tenders. Explicit legacy type=tender selections remain available; the separate tender directory represents issued notices and procurement plans.","A missing requested edition is an explicitly marked English card with its real English citation URL. No translation, source fact or publication date is invented.","htmlIndexable describes the linked HTML selection; this JSON representation remains noindex,follow. Preserve citations, source rights, dates, scope and unknown values. GET/HEAD only."]}