34/8-4 A
Partial source coverage. Status and company roles are reported by each source, not independently verified as current. Unknown does not mean zero.
- Name / source ID
- 34/8-4
- Borehole / source record ID
- 1909
- Sector
- Oil and gas
- Derived purpose group
- Appraisal
- Operator in source snapshot
- Norsk Hydro Produksjon AS
- Recorded spud date
- 1992-02-18
- Recorded completion date
- 1992-05-27
- Latitude / longitude (WGS84)
- 61.324387 / 2.420093
- Source-reported measurements
- 3567 m MD · RKB
- Status reported by source
- P&A
- Source accessed
- 2026-10-02
- Source snapshot date
- Not reported / not verified
- Original coordinate reference system
- ED50 / service geometry EPSG:4326
- Drilling facility reported by source
- TRANSOCEAN 8
Company roles reported by source
- Drilling operatorNorsk Hydro Produksjon ASOpen source record ↗
| Source-reported measurements | Value | Reference |
|---|---|---|
| wlbTotalDepth | 3,567.00 m | RKB |
| wlbFinalVerticalDepth | 3,313.00 m | RKB |
| wlbWaterDepth | 309.00 m | Not reported / not verified |
| wlbBottomHoleTemperature | 123.00 °C | Not reported / not verified |
Norwegian Offshore Directorate — Wellbores ↗
Source accessed:
Reuse terms: review-source-terms
Source terms and attribution ↗Norwegian Offshore Directorate (NOD/SODIR), NLOD 2.0. Normalized by Wellficent.
Nearby wells and heat flow
These tools are descriptive: not forecasts, reserve estimates or investment advice. Source coverage is partial; unknown does not mean zero.
| Name | Distance | Source-reported measurements | Source catalogues |
|---|---|---|---|
| 34/8-4 S | 0.00 km | 4,150 m | Norwegian Offshore Directorate — Wellbores |
| 34/8-4 AR | 0.00 km | 3,574 m | Norwegian Offshore Directorate — Wellbores |
| 34/8-9 S | 2.16 km | 3,530 m | Norwegian Offshore Directorate — Wellbores |
| 34/8-10 S | 3.78 km | 3,470 m | Norwegian Offshore Directorate — Wellbores |
| 34/8-5 | 3.87 km | 3,540 m | Norwegian Offshore Directorate — Wellbores |
| 34/8-U-2 | 4.10 km | Not reported / not verified m | Norwegian Offshore Directorate — Wellbores |
| 34/8-V-4 DH | 4.11 km | 6,905 m | Norwegian Offshore Directorate — Wellbores |
| 34/8-V-4 EH | 4.11 km | Not reported / not verified m | Norwegian Offshore Directorate — Wellbores |
| 34/8-V-4 H | 4.11 km | 3,181 m | Norwegian Offshore Directorate — Wellbores |
| 34/8-V-4 AH | 4.11 km | 4,160 m | Norwegian Offshore Directorate — Wellbores |
| 34/8-V-4 BY1H | 4.11 km | 4,721 m | Norwegian Offshore Directorate — Wellbores |
| 34/8-V-4 BY2H | 4.11 km | 4,815 m | Norwegian Offshore Directorate — Wellbores |
Digital well log
SODIR formation tops, drilling-mud samples and well tests on one measured-depth section.
- Total depth
- 3567
- True vertical depth (RKB)
- 3313
- Water depth
- 309
- Bottom-hole temperature
- 123
| Group | Formation | Depth (m MD, RKB) |
|---|---|---|
| GROUP | NORDLAND GP | 333 / 1,109 |
| FORMATION | UTSIRA FM | 1,072 / 1,820 |
| GROUP | HORDALAND GP | 1,109 / 1,820 |
| GROUP | ROGALAND GP | 1,820 / 2,031 |
| FORMATION | BALDER FM | 1,820 / 1,863 |
| FORMATION | SELE FM | 1,863 / 1,876 |
| FORMATION | LISTA FM | 1,876 / 2,903 |
| GROUP | SHETLAND GP | 2,031 / 2,894 |
| GROUP | CROMER KNOLL GP | 2,894 / 2,903 |
| GROUP | DUNLIN GP | 2,903 / 3,057 |
| FORMATION | AMUNDSEN FM | 2,903 / 3,143 |
| GROUP | STATFJORD GP | 3,057 / 3,143 |
| GROUP | HEGRE GP | 3,143 / 3,567 |
| FORMATION | LUNDE FM | 3,143 / 3,567 |
| Depth (m MD, RKB) | Mud density (g/cm³) | Quality flags |
|---|---|---|
| 550 | 1.71 | observation-date-unreported, zero-meaning-unresolved |
| 2188 | 1.64 | observation-date-unreported, zero-meaning-unresolved |
| 2230 | 1.7 | observation-date-unreported, zero-meaning-unresolved |
| 2250 | 1.64 | observation-date-unreported, zero-meaning-unresolved |
| 2434 | 1.64 | observation-date-unreported, zero-meaning-unresolved |
| 2509 | 1.63 | observation-date-unreported, zero-meaning-unresolved |
| 2615 | 1.64 | observation-date-unreported, zero-meaning-unresolved |
| 2700 | 1.7 | observation-date-unreported, zero-meaning-unresolved |
| 2813 | 1.64 | observation-date-unreported, zero-meaning-unresolved |
| 2909 | 1.64 | observation-date-unreported, zero-meaning-unresolved |
| 2914 | 1.64 | observation-date-unreported, zero-meaning-unresolved |
| 2994 | 1.64 | observation-date-unreported, zero-meaning-unresolved |
| 3012 | 1.7 | observation-date-unreported, zero-meaning-unresolved |
| 3037 | 1.7 | observation-date-unreported, zero-meaning-unresolved |
| 3042 | 1.65 | observation-date-unreported, zero-meaning-unresolved |
| 3073 | 1.66 | observation-date-unreported, zero-meaning-unresolved |
| 3103 | 1.66 | observation-date-unreported, zero-meaning-unresolved |
| 3114 | 1.66 | observation-date-unreported, zero-meaning-unresolved |
| 3120 | 1.66 | observation-date-unreported, zero-meaning-unresolved |
| 3144 | 1.7 | observation-date-unreported, zero-meaning-unresolved |
| 3147 | 1.66 | observation-date-unreported, zero-meaning-unresolved |
| 3150 | 1.7 | observation-date-unreported, zero-meaning-unresolved |
| 3156 | 1.66 | observation-date-unreported, zero-meaning-unresolved |
| 3156 | 1.66 | observation-date-unreported, zero-meaning-unresolved |
| 3183 | 1.65 | observation-date-unreported, zero-meaning-unresolved |
| 3197 | 1.7 | observation-date-unreported, zero-meaning-unresolved |
| 3198 | 1.65 | observation-date-unreported, zero-meaning-unresolved |
| 3200 | 1.65 | observation-date-unreported, zero-meaning-unresolved |
| 3202 | 1.65 | observation-date-unreported, zero-meaning-unresolved |
| 3248 | 1.7 | observation-date-unreported, zero-meaning-unresolved |
| 3259 | 1.65 | observation-date-unreported, zero-meaning-unresolved |
| 3272 | 1.65 | observation-date-unreported, zero-meaning-unresolved |
| 3342 | 1.65 | observation-date-unreported, zero-meaning-unresolved |
| 3447 | 1.65 | observation-date-unreported, zero-meaning-unresolved |
| 3500 | 1.71 | observation-date-unreported, zero-meaning-unresolved |
| 3504 | 1.65 | observation-date-unreported, zero-meaning-unresolved |
| 3567 | 1.64 | observation-date-unreported, zero-meaning-unresolved |
| Well tests | Depth (m MD, RKB) | Measurements |
|---|---|---|
| 5 | 2988 / 3019 | {"test-from-depth":{"value":2988,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3019,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":14.3,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":26,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":[]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":44,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":[]},"downhole-temperature":{"value":109,"unit":"degC","reference":"DST","qualityFlags":[]},"test-oil-flow":{"value":992,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":225184,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.82,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0.74,"unit":"1","reference":"air = 1","qualityFlags":[]},"test-gas-oil-ratio":{"value":227,"unit":"m3/m3","reference":"DST","qualityFlags":[]}} |
| 4 | 3056 / 3108 | {"test-from-depth":{"value":3056,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3108,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":12.7,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":26,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":[]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":45,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":[]},"downhole-temperature":{"value":110,"unit":"degC","reference":"DST","qualityFlags":[]},"test-oil-flow":{"value":831,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":181158,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.821,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0.74,"unit":"1","reference":"air = 1","qualityFlags":[]},"test-gas-oil-ratio":{"value":218,"unit":"m3/m3","reference":"DST","qualityFlags":[]}} |
| 3 | 3160 / 3184 | {"test-from-depth":{"value":3160,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3184,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":19,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":11,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":[]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":27,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":[]},"downhole-temperature":{"value":113,"unit":"degC","reference":"DST","qualityFlags":[]},"test-oil-flow":{"value":821,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":170768,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.82,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0.74,"unit":"1","reference":"air = 1","qualityFlags":[]},"test-gas-oil-ratio":{"value":208,"unit":"m3/m3","reference":"DST","qualityFlags":[]}} |
| 2 | 3214 / 3228 | {"test-from-depth":{"value":3214,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3228,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":12.7,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":1,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":[]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":7,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":[]},"downhole-temperature":{"value":105,"unit":"degC","reference":"DST","qualityFlags":[]},"test-oil-flow":{"value":35,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":15680,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.8,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0.81,"unit":"1","reference":"air = 1","qualityFlags":[]},"test-gas-oil-ratio":{"value":448,"unit":"m3/m3","reference":"DST","qualityFlags":[]}} |
| 1 | 3323 / 3341 | {"test-from-depth":{"value":3323,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3341,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":14.2,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":23,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":[]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":49,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":[]},"downhole-temperature":{"value":118,"unit":"degC","reference":"DST","qualityFlags":[]},"test-oil-flow":{"value":936,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":211536,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.815,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0.77,"unit":"1","reference":"air = 1","qualityFlags":[]},"test-gas-oil-ratio":{"value":226,"unit":"m3/m3","reference":"DST","qualityFlags":[]}} |
Group tops in offset wells
Group tops below each borehole's own RKB. Not TVD below sea level; deviation and kelly-bushing elevations affect apparent depths.
| Group | 34/8-4 A | 34/8-4 S | 34/8-4 AR | 34/8-9 S | 34/8-10 S |
|---|---|---|---|---|---|
| NORDLAND GP | 332.5 | 332 | 340 | 330 | 349 |
| HORDALAND GP | 1108.5 | 1108 | 1116 | 1160 | 1145 |
| ROGALAND GP | 1819.5 | 1819 | 1827 | 1842 | 1815 |
| SHETLAND GP | 2030.5 | 2030 | 2038 | 2036.5 | 1994 |
| CROMER KNOLL GP | 2894 | 2899 | 2901.5 | 2903.5 | 2871 |
| BRENT GP | — | 2903 | — | 2922.7 | 2879.3 |
| DUNLIN GP | 2902.5 | 2923.5 | 2910 | 2983.5 | 2885 |
| VIKING GP | — | 2902 | — | 2908 | — |
| HEGRE GP | 3143.3 | 2950 | 3150.8 | 3245.1 | 3125 |
| STATFJORD GP | 3057 | — | 3064.5 | 3150 | 3038.5 |
Subsurface temperature and heat flow
Compare bottom-hole temperatures with depth and see measured heat flow near wells: context for geothermal reuse.
| Name | Distance | Subsurface temperature and heat flow | Quality flags |
|---|---|---|---|
| R24-P060200 | 91.89 km | 60.30 mW/m2 | {"qualityScores":["Ux.Mx.-------"]} |
IHFC · Global Heat Flow Database, Release 2024 (v. 2026.03) ↗
Source accessed:
Reuse terms: CC-BY-4.0
Source terms and attribution ↗Global Heat Flow Data Assessment Group et al. (2024): The Global Heat Flow Database: Release 2024. V. 2026.03. GFZ Data Services. https://doi.org/10.5880/fidgeo.2024.014 Licensed under CC BY 4.0. Wellficent shows parent-level site values and selected metadata; values are not modified.