FROM WELLHEAD TO MARKET. NEWS WITH SOURCES.
Our standards
wellficent.
Read energy from subsurface to market.
See what moves next.
WELL & ENERGY INTELLIGENCE
← Back to well atlas

2/4-7

Partial source coverage. Status and company roles are reported by each source, not independently verified as current. Unknown does not mean zero.

Name / source ID
2/4-7
Borehole / source record ID
196
Sector
Oil and gas
Derived purpose group
Appraisal
Operator in source snapshot
Phillips Petroleum Company Norway
Recorded spud date
1971-07-24
Recorded completion date
1971-10-08
Latitude / longitude (WGS84)
56.634174 / 3.277737
Source-reported measurements
3494 m MD · RKB
Status reported by source
P&A
Source accessed
2026-10-02
Source snapshot date
Not reported / not verified
Original coordinate reference system
ED50 / service geometry EPSG:4326
Drilling facility reported by source
MÆRSK EXPLORER

Company roles reported by source

Source-reported measurements
Source-reported measurementsValueReference
wlbTotalDepth3,494.00 mRKB
wlbWaterDepth68.00 mNot reported / not verified
wlbBottomHoleTemperature142.00 °CNot reported / not verified
Open source record ↗

Nearby wells and heat flow

These tools are descriptive: not forecasts, reserve estimates or investment advice. Source coverage is partial; unknown does not mean zero.

Nearby wells and heat flow
NameDistanceSource-reported measurementsSource catalogues
2/4-U-721.04 km108 mNorwegian Offshore Directorate — Wellbores
2/4-U-681.29 km108 mNorwegian Offshore Directorate — Wellbores
2/4-YA-2 H1.32 km5,862 mNorwegian Offshore Directorate — Wellbores
2/4-YA-1 H1.32 km4,227 mNorwegian Offshore Directorate — Wellbores
2/4-U-671.32 km78 mNorwegian Offshore Directorate — Wellbores
2/4-U-701.33 km107 mNorwegian Offshore Directorate — Wellbores
2/4-YA-4 H1.33 km4,752 mNorwegian Offshore Directorate — Wellbores
2/4-YA-3 H1.33 km4,546 mNorwegian Offshore Directorate — Wellbores
2/4-YA-3 AH1.33 km4,482 mNorwegian Offshore Directorate — Wellbores
2/4-U-691.36 km108 mNorwegian Offshore Directorate — Wellbores
2/4-U-711.36 km109 mNorwegian Offshore Directorate — Wellbores
2/4-U-631.82 km108 mNorwegian Offshore Directorate — Wellbores

Digital well log

SODIR formation tops, drilling-mud samples and well tests on one measured-depth section.

Total depth
3494
True vertical depth (RKB)
—
Water depth
68
Bottom-hole temperature
142
2/4-7 · Digital well log0874174726213494NORDLAND GPHORDALAND GPROGALAND GPSHETLAND GP
Depth (m MD, RKB)
Digital well log
GroupFormationDepth (m MD, RKB)
GROUPNORDLAND GP102 / 1,736
GROUPHORDALAND GP1,736 / 3,048
GROUPROGALAND GP3,048 / 3,175
FORMATIONBALDER FM3,048 / 3,060
FORMATIONSELE FM3,060 / 3,070
FORMATIONLISTA FM3,070 / 3,162
FORMATIONVÅLE FM3,162 / 3,175
GROUPSHETLAND GP3,175 / 3,494
FORMATIONEKOFISK FM3,175 / 3,304
FORMATIONTOR FM3,304 / 3,494
Mud density (g/cm³)
Depth (m MD, RKB)Mud density (g/cm³)Quality flags
1861.12observation-date-unreported, zero-meaning-unresolved
5641.36observation-date-unreported, zero-meaning-unresolved
13621.72observation-date-unreported, zero-meaning-unresolved
28351.71observation-date-unreported, zero-meaning-unresolved
31551.71observation-date-unreported, zero-meaning-unresolved
33331.72observation-date-unreported, zero-meaning-unresolved
Well tests
Well testsDepth (m MD, RKB)Measurements
53176 / 3204{"test-from-depth":{"value":3176,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3204,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":0,"unit":"mm","reference":null,"qualityFlags":["zero-meaning-unresolved"]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"test-gas-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"oil-density":{"value":0,"unit":"g/cm3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}}
63176 / 3182{"test-from-depth":{"value":3176,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3182,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":0,"unit":"mm","reference":null,"qualityFlags":["zero-meaning-unresolved"]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"test-gas-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"oil-density":{"value":0,"unit":"g/cm3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}}
73189 / 3204{"test-from-depth":{"value":3189,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3204,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":0,"unit":"mm","reference":null,"qualityFlags":["zero-meaning-unresolved"]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"test-gas-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"oil-density":{"value":0,"unit":"g/cm3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}}
43250 / 3261{"test-from-depth":{"value":3250,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3261,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":0,"unit":"mm","reference":null,"qualityFlags":["zero-meaning-unresolved"]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"test-gas-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"oil-density":{"value":0,"unit":"g/cm3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}}
33304 / 3329{"test-from-depth":{"value":3304,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3329,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":0,"unit":"mm","reference":null,"qualityFlags":["zero-meaning-unresolved"]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":129,"unit":"degC","reference":"DST","qualityFlags":[]},"test-oil-flow":{"value":551,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":736231,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0,"unit":"g/cm3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}}
23346 / 3349{"test-from-depth":{"value":3346,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3349,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":0,"unit":"mm","reference":null,"qualityFlags":["zero-meaning-unresolved"]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":139,"unit":"degC","reference":"DST","qualityFlags":[]},"test-oil-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"test-gas-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"oil-density":{"value":0,"unit":"g/cm3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}}
13367 / 3370{"test-from-depth":{"value":3367,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3370,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":0,"unit":"mm","reference":null,"qualityFlags":["zero-meaning-unresolved"]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":138,"unit":"degC","reference":"DST","qualityFlags":[]},"test-oil-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"test-gas-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"oil-density":{"value":0,"unit":"g/cm3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}}

Subsurface temperature and heat flow

Compare bottom-hole temperatures with depth and see measured heat flow near wells: context for geothermal reuse.

Subsurface temperature and heat flow
NameDistanceSubsurface temperature and heat flowQuality flags
R24-P00324540.84 km62.00 mW/m2{"qualityScores":["Ux.Mx.-------"]}
R24-P00323946.42 km64.00 mW/m2{"qualityScores":["Ux.Mx.-------"]}
R24-P00324448.83 km63.00 mW/m2{"qualityScores":["Ux.Mx.-------"]}
R24-P00324350.47 km47.00 mW/m2{"qualityScores":["Ux.Mx.-------"]}
R24-P00322754.75 km66.00 mW/m2{"qualityScores":["Ux.Mx.-------"]}
w.

Beyond the wellhead, context.

A source-linked view of wells, energy and markets in seven languages.

Follow via RSS ↗