FROM WELLHEAD TO MARKET. NEWS WITH SOURCES.
Our standards
wellficent.
Read energy from subsurface to market.
See what moves next.
WELL & ENERGY INTELLIGENCE
← Back to well atlas

15/9-6

Partial source coverage. Status and company roles are reported by each source, not independently verified as current. Unknown does not mean zero.

Name / source ID
15/9-6
Borehole / source record ID
231
Sector
Oil and gas
Derived purpose group
Appraisal
Operator in source snapshot
Den norske stats oljeselskap a.s
Recorded spud date
1980-05-07
Recorded completion date
1980-09-07
Latitude / longitude (WGS84)
58.453137 / 1.690422
Source-reported measurements
3946 m MD · RKB
Status reported by source
P&A
Source accessed
2026-10-02
Source snapshot date
Not reported / not verified
Original coordinate reference system
ED50 / service geometry EPSG:4326
Drilling facility reported by source
NORSKALD

Company roles reported by source

Source-reported measurements
Source-reported measurementsValueReference
wlbTotalDepth3,946.00 mRKB
wlbFinalVerticalDepth3,945.00 mRKB
wlbWaterDepth112.00 mNot reported / not verified
wlbBottomHoleTemperature107.00 °CNot reported / not verified
Open source record ↗

Nearby wells and heat flow

These tools are descriptive: not forecasts, reserve estimates or investment advice. Source coverage is partial; unknown does not mean zero.

Nearby wells and heat flow
NameDistanceSource-reported measurementsSource catalogues
15/9-121.53 km3,740 mNorwegian Offshore Directorate — Wellbores
15/9-12 R1.53 km3,740 mNorwegian Offshore Directorate — Wellbores
15/9-23.21 km3,764 mNorwegian Offshore Directorate — Wellbores
15/9-33.60 km3,796 mNorwegian Offshore Directorate — Wellbores
15/6-U-23.61 km222 mNorwegian Offshore Directorate — Wellbores
15/9-14.10 km3,734 mNorwegian Offshore Directorate — Wellbores
15/9-U-64.16 kmNot reported / not verified mNorwegian Offshore Directorate — Wellbores
15/9-U-74.23 kmNot reported / not verified mNorwegian Offshore Directorate — Wellbores
15/9-B-44.25 km6,476 mNorwegian Offshore Directorate — Wellbores
15/9-B-4 A4.25 km7,690 mNorwegian Offshore Directorate — Wellbores
15/9-B-34.25 km3,764 mNorwegian Offshore Directorate — Wellbores
15/9-B-24.25 km7,824 mNorwegian Offshore Directorate — Wellbores

Digital well log

SODIR formation tops, drilling-mud samples and well tests on one measured-depth section.

Total depth
3946
True vertical depth (RKB)
3945
Water depth
112
Bottom-hole temperature
107
15/9-6 · Digital well log0987197329603946NORDLAND GPHORDALAND GPROGALAND GPSHETLAND GPCROMER KNOLL GPVIKING GPVESTLAND GP
Depth (m MD, RKB)
Digital well log
GroupFormationDepth (m MD, RKB)
GROUPNORDLAND GP137 / 1,063
FORMATIONUTSIRA FM834 / 1,807
GROUPHORDALAND GP1,063 / 2,228
FORMATIONFRIGG FM1,807 / 2,228
GROUPROGALAND GP2,228 / 2,722
FORMATIONBALDER FM2,228 / 2,278
FORMATIONSELE FM2,278 / 2,338
FORMATIONLISTA FM2,338 / 2,381
FORMATIONHEIMDAL FM2,381 / 2,617
FORMATIONLISTA FM2,617 / 2,650
FORMATIONTY FM2,650 / 2,665
FORMATIONVÅLE FM2,665 / 2,722
GROUPSHETLAND GP2,722 / 3,392
FORMATIONEKOFISK FM2,722 / 2,765
FORMATIONTOR FM2,765 / 2,952
FORMATIONHOD FM2,952 / 3,317
FORMATIONBLODØKS FM3,317 / 3,350
FORMATIONHIDRA FM3,350 / 3,392
GROUPCROMER KNOLL GP3,392 / 3,470
FORMATIONRØDBY FM3,392 / 3,470
GROUPVIKING GP3,470 / 3,762
FORMATIONDRAUPNE FM3,470 / 3,700
FORMATIONHEATHER FM3,700 / 3,762
GROUPVESTLAND GP3,762 / 3,946
FORMATIONHUGIN FM3,762 / 3,786
FORMATIONSLEIPNER FM3,786 / 3,828
FORMATIONSKAGERRAK FM3,828 / 3,946
Mud density (g/cm³)
Depth (m MD, RKB)Mud density (g/cm³)Quality flags
4901.04observation-date-unreported, zero-meaning-unresolved
10301.17observation-date-unreported, zero-meaning-unresolved
15801.21observation-date-unreported, zero-meaning-unresolved
32921.35observation-date-unreported, zero-meaning-unresolved
35001.45observation-date-unreported, zero-meaning-unresolved
Well tests
Well testsDepth (m MD, RKB)Measurements
33555 / 3565{"test-from-depth":{"value":3555,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3565,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":0,"unit":"mm","reference":null,"qualityFlags":["zero-meaning-unresolved"]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"test-gas-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"oil-density":{"value":0,"unit":"g/cm3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}}
23637 / 3638{"test-from-depth":{"value":3637,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3638,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":0,"unit":"mm","reference":null,"qualityFlags":["zero-meaning-unresolved"]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"test-gas-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"oil-density":{"value":0,"unit":"g/cm3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}}
13671 / 3674{"test-from-depth":{"value":3671,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3674,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":0,"unit":"mm","reference":null,"qualityFlags":["zero-meaning-unresolved"]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"test-gas-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"oil-density":{"value":0,"unit":"g/cm3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}}

Group tops in offset wells

Group tops below each borehole's own RKB. Not TVD below sea level; deviation and kelly-bushing elevations affect apparent depths.

Group tops in offset wells
Group15/9-615/9-1215/9-215/9-315/9-1
NORDLAND GP137135133139131
HORDALAND GP10631066109411121065
ROGALAND GP22282220228721332227
SHETLAND GP27222723276226362742.5
CROMER KNOLL GP33923295330332853300
VIKING GP34703400339633643377
VESTLAND GP37623510348334983530
HEGRE GP——3699——
NO GROUP DEFINED————3701

Subsurface temperature and heat flow

Compare bottom-hole temperatures with depth and see measured heat flow near wells: context for geothermal reuse.

Subsurface temperature and heat flow
NameDistanceSubsurface temperature and heat flowQuality flags
R24-P00321470.94 km50.00 mW/m2{"qualityScores":["Ux.Mx.-------"]}
R24-P00322174.62 km74.00 mW/m2{"qualityScores":["Ux.Mx.-------"]}
R24-P00322889.32 km54.00 mW/m2{"qualityScores":["Ux.Mx.-------"]}
R24-P00322090.68 km53.00 mW/m2{"qualityScores":["Ux.Mx.-------"]}
R24-P03136691.45 km66.50 mW/m2{"qualityScores":["U1.M3.SXXP-X-"]}
w.

Beyond the wellhead, context.

A source-linked view of wells, energy and markets in five languages.