FROM WELLHEAD TO MARKET. NEWS WITH SOURCES.
Our standards
wellficent.
Read energy from subsurface to market.
See what moves next.
WELL & ENERGY INTELLIGENCE
← Back to well atlas

2/9-5 S

Partial source coverage. Status and company roles are reported by each source, not independently verified as current. Unknown does not mean zero.

Name / source ID
2/9-5
Borehole / source record ID
7502
Sector
Oil and gas
Derived purpose group
Exploration
Operator in source snapshot
Det norske oljeselskap ASA
Recorded spud date
2014-07-21
Recorded completion date
2014-09-18
Latitude / longitude (WGS84)
56.411980 / 3.916868
Source-reported measurements
3679 m MD · RKB
Status reported by source
P&A
Source accessed
2026-10-02
Source snapshot date
Not reported / not verified
Original coordinate reference system
ED50 / service geometry EPSG:4326
Drilling facility reported by source
MÆRSK GIANT

Company roles reported by source

Source-reported measurements
Source-reported measurementsValueReference
wlbTotalDepth3,679.00 mRKB
wlbFinalVerticalDepth3,660.00 mRKB
wlbWaterDepth65.00 mNot reported / not verified
Open source record ↗

Nearby wells and heat flow

These tools are descriptive: not forecasts, reserve estimates or investment advice. Source coverage is partial; unknown does not mean zero.

Nearby wells and heat flow
NameDistanceSource-reported measurementsSource catalogues
2/9-U-96.11 km102 mNorwegian Offshore Directorate — Wellbores
2/9-U-106.12 km102 mNorwegian Offshore Directorate — Wellbores
2/9-U-86.18 km102 mNorwegian Offshore Directorate — Wellbores
2/9-U-66.18 kmNot reported / not verified mNorwegian Offshore Directorate — Wellbores
2/9-U-56.18 km105 mNorwegian Offshore Directorate — Wellbores
2/9-U-76.23 km155 mNorwegian Offshore Directorate — Wellbores
2/9-6 S6.23 km4,330 mNorwegian Offshore Directorate — Wellbores
2/9-U-46.24 km105 mNorwegian Offshore Directorate — Wellbores
2/9-U-126.93 km107 mNorwegian Offshore Directorate — Wellbores
2/9-U-136.93 km105 mNorwegian Offshore Directorate — Wellbores
2/9-U-116.99 km105 mNorwegian Offshore Directorate — Wellbores
2/9-27.13 km4,367 mNorwegian Offshore Directorate — Wellbores

Digital well log

SODIR formation tops, drilling-mud samples and well tests on one measured-depth section.

Total depth
3679
True vertical depth (RKB)
3660
Water depth
65
Bottom-hole temperature
—
2/9-5 S · Digital well log0920184027593679NORDLAND GPHORDALAND GPROGALAND GPSHETLAND GPTYNE GPZECHSTEIN GPROTLIEGEND GPBASEMENT
Depth (m MD, RKB)
Digital well log
GroupFormationDepth (m MD, RKB)
GROUPNORDLAND GP108 / 1,563
FORMATIONUNDIFFERENTIATED108 / 1,563
GROUPHORDALAND GP1,563 / 2,845
FORMATIONUNDIFFERENTIATED1,563 / 2,845
GROUPROGALAND GP2,845 / 2,944
FORMATIONBALDER FM2,845 / 2,864
FORMATIONSELE FM2,864 / 2,896
FORMATIONLISTA FM2,896 / 2,934
FORMATIONVÅLE FM2,934 / 2,944
GROUPSHETLAND GP2,944 / 3,430
FORMATIONEKOFISK FM2,944 / 3,021
FORMATIONTOR FM3,021 / 3,312
FORMATIONHOD FM3,312 / 3,430
GROUPTYNE GP3,430 / 3,547
FORMATIONFARSUND FM3,430 / 3,679
GROUPZECHSTEIN GP3,547 / 3,556
GROUPROTLIEGEND GP3,556 / 3,671
GROUPBASEMENT3,671 / 3,679
Mud density (g/cm³)
Depth (m MD, RKB)Mud density (g/cm³)Quality flags
8101.1observation-date-unreported, zero-meaning-unresolved
8131.3observation-date-unreported, zero-meaning-unresolved
12501.45observation-date-unreported, zero-meaning-unresolved
18101.46observation-date-unreported, zero-meaning-unresolved
33521.65observation-date-unreported, zero-meaning-unresolved
35871.74observation-date-unreported, zero-meaning-unresolved

Group tops in offset wells

Group tops below each borehole's own RKB. Not TVD below sea level; deviation and kelly-bushing elevations affect apparent depths.

Group tops in offset wells
Group2/9-5 S2/9-6 S2/9-2
NORDLAND GP108126.593
HORDALAND GP156316251560
ROGALAND GP284530352927
SHETLAND GP294431503039
TYNE GP343038903653
CROMER KNOLL GP—36743471
ZECHSTEIN GP3547——
ROTLIEGEND GP3556—4316
BASEMENT3671——
VESTLAND GP——4292

Subsurface temperature and heat flow

Compare bottom-hole temperatures with depth and see measured heat flow near wells: context for geothermal reuse.

Subsurface temperature and heat flow
NameDistanceSubsurface temperature and heat flowQuality flags
R24-P00405537.45 km66.00 mW/m2{"qualityScores":["Ux.Mx.-------"]}
R24-P00405442.95 km65.00 mW/m2{"qualityScores":["Ux.Mx.-------"]}
R24-P00404644.93 km72.00 mW/m2{"qualityScores":["Ux.Mx.-------"]}
R24-P00406057.85 km78.00 mW/m2{"qualityScores":["Ux.Mx.-------"]}
R24-P00260458.01 km40.00 mW/m2{"qualityScores":["Ux.Mx.-------"]}
w.

Beyond the wellhead, context.

A source-linked view of wells, energy and markets in five languages.

Follow via RSS ↗