2/4-3
Partial source coverage. Status and company roles are reported by each source, not independently verified as current. Unknown does not mean zero.
- Name / source ID
- 2/4-3
- Borehole / source record ID
- 97
- Sector
- Oil and gas
- Derived purpose group
- Appraisal
- Operator in source snapshot
- Phillips Petroleum Company Norway
- Recorded spud date
- 1970-01-27
- Recorded completion date
- 1970-05-31
- Latitude / longitude (WGS84)
- 56.544371 / 3.247237
- Source-reported measurements
- 3431 m MD · RKB
- Status reported by source
- P&A
- Source accessed
- 2026-10-02
- Source snapshot date
- Not reported / not verified
- Original coordinate reference system
- ED50 / service geometry EPSG:4326
- Drilling facility reported by source
- OCEAN VIKING
Company roles reported by source
- Drilling operatorPhillips Petroleum Company NorwayOpen source record ↗
| Source-reported measurements | Value | Reference |
|---|---|---|
| wlbTotalDepth | 3,431.00 m | RKB |
| wlbWaterDepth | 71.00 m | Not reported / not verified |
| wlbBottomHoleTemperature | 138.00 °C | Not reported / not verified |
Norwegian Offshore Directorate — Wellbores ↗
Source accessed:
Reuse terms: review-source-terms
Source terms and attribution ↗Norwegian Offshore Directorate (NOD/SODIR), NLOD 2.0. Normalized by Wellficent.
Nearby wells and heat flow
These tools are descriptive: not forecasts, reserve estimates or investment advice. Source coverage is partial; unknown does not mean zero.
| Name | Distance | Source-reported measurements | Source catalogues |
|---|---|---|---|
| 2/4-A-93 | 0.00 km | 3,431 m | Norwegian Offshore Directorate — Wellbores |
| 2/4-U-26 | 1.28 km | 127 m | Norwegian Offshore Directorate — Wellbores |
| 2/4-U-23 | 1.30 km | 128 m | Norwegian Offshore Directorate — Wellbores |
| 2/4-U-25 | 1.31 km | 127 m | Norwegian Offshore Directorate — Wellbores |
| 2/4-U-19 | 1.33 km | 143 m | Norwegian Offshore Directorate — Wellbores |
| 2/4-Z-36 | 1.34 km | 6,507 m | Norwegian Offshore Directorate — Wellbores |
| 2/4-Z-36 A | 1.34 km | 5,154 m | Norwegian Offshore Directorate — Wellbores |
| 2/4-Z-36 AY2 | 1.34 km | Not reported / not verified m | Norwegian Offshore Directorate — Wellbores |
| 2/4-Z-36 AY3 | 1.34 km | Not reported / not verified m | Norwegian Offshore Directorate — Wellbores |
| 2/4-Z-36 B | 1.34 km | Not reported / not verified m | Norwegian Offshore Directorate — Wellbores |
| 2/4-Z-35 | 1.34 km | 4,781 m | Norwegian Offshore Directorate — Wellbores |
| 2/4-Z-30 | 1.34 km | 4,708 m | Norwegian Offshore Directorate — Wellbores |
Digital well log
SODIR formation tops, drilling-mud samples and well tests on one measured-depth section.
- Total depth
- 3431
- True vertical depth (RKB)
- —
- Water depth
- 71
- Bottom-hole temperature
- 138
| Group | Formation | Depth (m MD, RKB) |
|---|---|---|
| GROUP | NORDLAND GP | 98 / 1,730 |
| GROUP | HORDALAND GP | 1,730 / 2,960 |
| GROUP | ROGALAND GP | 2,960 / 3,090 |
| FORMATION | BALDER FM | 2,960 / 2,969 |
| FORMATION | SELE FM | 2,969 / 2,976 |
| FORMATION | LISTA FM | 2,976 / 3,005 |
| FORMATION | VIDAR FM | 3,005 / 3,023 |
| FORMATION | LISTA FM | 3,023 / 3,076 |
| FORMATION | VÅLE FM | 3,076 / 3,090 |
| GROUP | SHETLAND GP | 3,090 / 3,431 |
| FORMATION | EKOFISK FM | 3,090 / 3,253 |
| FORMATION | TOR FM | 3,253 / 3,431 |
| Depth (m MD, RKB) | Mud density (g/cm³) | Quality flags |
|---|---|---|
| 619 | 1.03 | observation-date-unreported, zero-meaning-unresolved |
| 1153 | 1.7 | observation-date-unreported, zero-meaning-unresolved |
| 1632 | 1.71 | observation-date-unreported, zero-meaning-unresolved |
| 2320 | 1.71 | observation-date-unreported, zero-meaning-unresolved |
| 3018 | 1.71 | observation-date-unreported, zero-meaning-unresolved |
| 3225 | 1.71 | observation-date-unreported, zero-meaning-unresolved |
| Well tests | Depth (m MD, RKB) | Measurements |
|---|---|---|
| 11 | 3015 / 3023 | {"test-from-depth":{"value":3015,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3023,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":25.4,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"test-gas-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"oil-density":{"value":0,"unit":"g/cm3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}} |
| 10 | 3124 / 3224 | {"test-from-depth":{"value":3124,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3224,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":19,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":28,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":[]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":38,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":[]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":595,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":132925,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.859,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}} |
| 9 | 3124 / 3154 | {"test-from-depth":{"value":3124,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3154,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":25.4,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":28,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":[]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":20,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":[]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":326,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":79240,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.849,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}} |
| 8 | 3139 / 3148 | {"test-from-depth":{"value":3139,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3148,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":6,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":28,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":[]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":46,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":[]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":186,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":39337,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.847,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}} |
| 6 | 3195 / 3226 | {"test-from-depth":{"value":3195,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3226,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":6.3,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":28.5,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":[]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":46,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":[]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":166,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":35799,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.848,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}} |
| 7 | 3195 / 3226 | {"test-from-depth":{"value":3195,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3226,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":19,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":28,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":[]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":33,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":[]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":609,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":129812,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.854,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}} |
| 5 | 3235 / 3244 | {"test-from-depth":{"value":3235,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3244,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":19,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":28,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":[]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":172,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":36337,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.853,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}} |
| 4 | 3268 / 3296 | {"test-from-depth":{"value":3268,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3296,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":28.5,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":328,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":62967,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.845,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}} |
| 3 | 3317 / 3320 | {"test-from-depth":{"value":3317,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3320,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":19,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":7.3,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":[]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":27.5,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":[]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":323,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":58581,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.855,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}} |
| 2 | 3332 / 3341 | {"test-from-depth":{"value":3332,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3341,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":25.4,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"test-gas-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"oil-density":{"value":0,"unit":"g/cm3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}} |
| 1 | 3354 / 3363 | {"test-from-depth":{"value":3354,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":3363,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":25.4,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"test-gas-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"oil-density":{"value":0,"unit":"g/cm3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}} |
Subsurface temperature and heat flow
Compare bottom-hole temperatures with depth and see measured heat flow near wells: context for geothermal reuse.
| Name | Distance | Subsurface temperature and heat flow | Quality flags |
|---|---|---|---|
| R24-P003245 | 35.01 km | 62.00 mW/m2 | {"qualityScores":["Ux.Mx.-------"]} |
| R24-P003244 | 43.59 km | 63.00 mW/m2 | {"qualityScores":["Ux.Mx.-------"]} |
| R24-P003239 | 44.08 km | 64.00 mW/m2 | {"qualityScores":["Ux.Mx.-------"]} |
| R24-P003243 | 45.02 km | 47.00 mW/m2 | {"qualityScores":["Ux.Mx.-------"]} |
| R24-P002604 | 46.14 km | 40.00 mW/m2 | {"qualityScores":["Ux.Mx.-------"]} |
IHFC · Global Heat Flow Database, Release 2024 (v. 2026.03) ↗
Source accessed:
Reuse terms: CC-BY-4.0
Source terms and attribution ↗Global Heat Flow Data Assessment Group et al. (2024): The Global Heat Flow Database: Release 2024. V. 2026.03. GFZ Data Services. https://doi.org/10.5880/fidgeo.2024.014 Licensed under CC BY 4.0. Wellficent shows parent-level site values and selected metadata; values are not modified.