FROM WELLHEAD TO MARKET. NEWS WITH SOURCES.
Our standards
wellficent.
Read energy from subsurface to market.
See what moves next.
WELL & ENERGY INTELLIGENCE
← Back to well atlas

6507/7-2

Partial source coverage. Status and company roles are reported by each source, not independently verified as current. Unknown does not mean zero.

Name / source ID
6507/7-2
Borehole / source record ID
464
Sector
Oil and gas
Derived purpose group
Exploration
Operator in source snapshot
Conoco Norway Inc.
Recorded spud date
1985-02-25
Recorded completion date
1985-06-10
Latitude / longitude (WGS84)
65.336498 / 7.307740
Source-reported measurements
3262 m MD · RKB
Status reported by source
P&A
Source accessed
2026-10-02
Source snapshot date
Not reported / not verified
Original coordinate reference system
ED50 / service geometry EPSG:4326
Drilling facility reported by source
NORTRYM

Company roles reported by source

Source-reported measurements
Source-reported measurementsValueReference
wlbTotalDepth3,262.00 mRKB
wlbFinalVerticalDepth3,260.00 mRKB
wlbWaterDepth351.00 mNot reported / not verified
wlbBottomHoleTemperature113.00 °CNot reported / not verified
Open source record ↗

Nearby wells and heat flow

These tools are descriptive: not forecasts, reserve estimates or investment advice. Source coverage is partial; unknown does not mean zero.

Nearby wells and heat flow
NameDistanceSource-reported measurementsSource catalogues
6507/7-U-51.24 km449 mNorwegian Offshore Directorate — Wellbores
6507/7-U-61.26 km376 mNorwegian Offshore Directorate — Wellbores
6507/7-A-41.27 km3,483 mNorwegian Offshore Directorate — Wellbores
6507/7-A-11.27 km4,978 mNorwegian Offshore Directorate — Wellbores
6507/7-A-1 A1.27 km5,062 mNorwegian Offshore Directorate — Wellbores
6507/7-A-21.27 km5,369 mNorwegian Offshore Directorate — Wellbores
6507/7-A-2 A1.27 km5,210 mNorwegian Offshore Directorate — Wellbores
6507/7-A-31.27 km5,021 mNorwegian Offshore Directorate — Wellbores
6507/7-A-3 A1.27 km5,048 mNorwegian Offshore Directorate — Wellbores
6507/7-A-51.27 km5,060 mNorwegian Offshore Directorate — Wellbores
6507/7-A-5 A1.27 km5,232 mNorwegian Offshore Directorate — Wellbores
6507/7-A-61.27 km4,601 mNorwegian Offshore Directorate — Wellbores

Digital well log

SODIR formation tops, drilling-mud samples and well tests on one measured-depth section.

Total depth
3262
True vertical depth (RKB)
3260
Water depth
351
Bottom-hole temperature
113
6507/7-2 · Digital well log0816163124473262NORDLAND GPHORDALAND GPROGALAND GPSHETLAND GPFANGST GPBÅT GP
Depth (m MD, RKB)
Digital well log
GroupFormationDepth (m MD, RKB)
GROUPNORDLAND GP376 / 1,863
FORMATIONNAUST FM376 / 1,454
FORMATIONKAI FM1,454 / 1,863
GROUPHORDALAND GP1,863 / 1,944
FORMATIONBRYGGE FM1,863 / 1,944
GROUPROGALAND GP1,944 / 2,042
FORMATIONTARE FM1,944 / 1,977
FORMATIONTANG FM1,977 / 2,217
GROUPSHETLAND GP2,042 / 2,203
GROUPFANGST GP2,203 / 2,217
GROUPBÅT GP2,217 / 3,262
FORMATIONROR FM2,217 / 2,285
FORMATIONTILJE FM2,285 / 2,482
FORMATIONÅRE FM2,482 / 3,262
Mud density (g/cm³)
Depth (m MD, RKB)Mud density (g/cm³)Quality flags
383zero-meaning-unresolved
4261.02zero-meaning-unresolved
4761.06zero-meaning-unresolved
4761.02zero-meaning-unresolved
4761.02zero-meaning-unresolved
8361.12
10301.12
10301.02
10301.02
10301.26
10301.26
10701.08
14861.35
16461.39
18621.43
20521.45
21101.48
21101.47
21101.47
21791.54
22281.56
22841.58
23131.58
23271.58
24031.58
24361.58
25821.58
26051.58
26101.58
26101.58
26101.58
26101.58
26101.58
26101.58
26101.58
26271.5
26451.48
26801.44
27281.42
28101.39
29171.39
29891.39
31351.39
32621.39
32621.39
32621.39
32621.39
32621.39
Well tests
Well testsDepth (m MD, RKB)Measurements
72203 / 2222{"test-from-depth":{"value":2203,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":2222,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":20.2,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":9,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":[]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":96,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":900000,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.755,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":9360,"unit":"m3/m3","reference":"DST","qualityFlags":[]}}
62232 / 2245{"test-from-depth":{"value":2232,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":2245,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":19.1,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":5,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":[]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":17,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":45000,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.755,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0.65,"unit":"1","reference":"air = 1","qualityFlags":[]},"test-gas-oil-ratio":{"value":2632,"unit":"m3/m3","reference":"DST","qualityFlags":[]}}
52290 / 2310{"test-from-depth":{"value":2290,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":2310,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":19.1,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":12,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":[]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":73,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":724000,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.754,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0.65,"unit":"1","reference":"air = 1","qualityFlags":[]},"test-gas-oil-ratio":{"value":9965,"unit":"m3/m3","reference":"DST","qualityFlags":[]}}
42330 / 2340{"test-from-depth":{"value":2330,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":2340,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":22.2,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":4,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":[]},"bottom-hole-pressure":{"value":25,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":[]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":902,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":68000,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.876,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0.66,"unit":"1","reference":"air = 1","qualityFlags":[]},"test-gas-oil-ratio":{"value":75,"unit":"m3/m3","reference":"DST","qualityFlags":[]}}
32356.5 / 2376{"test-from-depth":{"value":2356.5,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":2376,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":25.4,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":40,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":[]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":489,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":32000,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.982,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0.668,"unit":"1","reference":"air = 1","qualityFlags":[]},"test-gas-oil-ratio":{"value":65,"unit":"m3/m3","reference":"DST","qualityFlags":[]}}
22417 / 2439{"test-from-depth":{"value":2417,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":2439,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":25.4,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":0,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":704,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":34000,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.922,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0.617,"unit":"1","reference":"air = 1","qualityFlags":[]},"test-gas-oil-ratio":{"value":48,"unit":"m3/m3","reference":"DST","qualityFlags":[]}}
2.12417 / 2439{"test-from-depth":{"value":2417,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":2439,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":9.5,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":5,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":[]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":208,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":12000,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.91,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":57,"unit":"m3/m3","reference":"DST","qualityFlags":[]}}
2.22417 / 2439{"test-from-depth":{"value":2417,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":2439,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":9.5,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":5,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":[]},"bottom-hole-pressure":{"value":0,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":208,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":12000,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.91,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":57,"unit":"m3/m3","reference":"DST","qualityFlags":[]}}
2.32417 / 2439{"test-from-depth":{"value":2417,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":2439,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":25.4,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":6,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":[]},"final-flow-pressure":{"value":3,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":[]},"bottom-hole-pressure":{"value":25,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":[]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":704,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"test-gas-flow":{"value":34000,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":[]},"oil-density":{"value":0.92,"unit":"g/cm3","reference":"DST","qualityFlags":[]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":49,"unit":"m3/m3","reference":"DST","qualityFlags":[]}}
12521 / 2529{"test-from-depth":{"value":2521,"unit":"m","reference":null,"qualityFlags":[]},"test-to-depth":{"value":2529,"unit":"m","reference":null,"qualityFlags":[]},"choke-size":{"value":6.1,"unit":"mm","reference":null,"qualityFlags":[]},"final-shut-in-pressure":{"value":0,"unit":"MPa","reference":"DST final shut-in; pressure datum unreported","qualityFlags":["zero-meaning-unresolved"]},"final-flow-pressure":{"value":1,"unit":"MPa","reference":"DST final flow; pressure datum unreported","qualityFlags":[]},"bottom-hole-pressure":{"value":26,"unit":"MPa","reference":"DST bottom hole; pressure datum unreported","qualityFlags":[]},"downhole-temperature":{"value":0,"unit":"degC","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"test-oil-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"test-gas-flow":{"value":0,"unit":"Sm3/day","reference":"DST test flow; not sustained production","qualityFlags":["zero-meaning-unresolved"]},"oil-density":{"value":0,"unit":"g/cm3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]},"gas-relative-density":{"value":0,"unit":"1","reference":"air = 1","qualityFlags":["zero-meaning-unresolved"]},"test-gas-oil-ratio":{"value":0,"unit":"m3/m3","reference":"DST","qualityFlags":["zero-meaning-unresolved"]}}

Subsurface temperature and heat flow

Compare bottom-hole temperatures with depth and see measured heat flow near wells: context for geothermal reuse.

Subsurface temperature and heat flow
NameDistanceSubsurface temperature and heat flowQuality flags
R24-P0602112.47 km50.40 mW/m2{"qualityScores":["Ux.Mx.-------"]}
R24-P0602102.54 km46.30 mW/m2{"qualityScores":["Ux.Mx.-------"]}
R24-P06020926.44 km52.30 mW/m2{"qualityScores":["Ux.Mx.-------"]}
R24-P06020831.16 km50.00 mW/m2{"qualityScores":["Ux.Mx.-------"]}
R24-P06020736.51 km51.90 mW/m2{"qualityScores":["Ux.Mx.-------"]}
w.

Beyond the wellhead, context.

A source-linked view of wells, energy and markets in seven languages.

Follow via RSS ↗