Geothermal direct-use heat
Separate delivered thermal energy from pump electricity consumption.
Inputs are sent to the server for this calculation without being saved or added to the URL. Saving a scenario stores it only in this browser.
Worked example
Example inputs are illustrative, not data from a real well.
Calculation inputs
- Flow rate
- 50 m³/h
- Fluid density
- 1,000 kg/m³
- Fluid specific heat capacity
- 4.18 kJ/kg/K
- Supply temperature
- 80 °C
- Return temperature
- 40 °C
- Heat delivery efficiency
- 90 %
- Operating hours in the period
- 4,000 h
- Pump electrical input power
- 15 kW
Calculation result
- Temperature difference
- 40 K
- Gross thermal power
- 2,322.2222 kWₜₕ
- Delivered thermal power
- 2,090 kWₜₕ
- Delivered heat in the period
- 8,360 MWhₜₕ
- Pump electricity in the period
- 60,000 kWhₑ
- Delivered heat per unit of pump electricity
- 139.33333 ratio
Formula and assumptions
Single-phase, constant-density and constant-heat-capacity approximation for direct heat use. Supply and return must use the same temperature basis. The user-selected delivery efficiency accounts for heat losses. Thermal output and pump electricity are separate energy streams; thermal kW is not electrical generation. Phase change, reservoir sustainability and heat-exchanger design are excluded.
Pₜ = ρ × (Q / 3600) × cₚ × (T_supply − T_return); P_delivered = Pₜ × η / 100; Eₜ = P_delivered × h / 1000; E_pump = P_pump × h; ratio = P_delivered / P_pumpMethod references