FROM WELLHEAD TO MARKET. NEWS WITH SOURCES.
Our standards
wellficent.
Global energy, wells and resources.
News, data and analysis.
WELL & ENERGY INTELLIGENCE
WELLFICENT / Well tools← All tools

Pump energy and cost

Estimate electricity, cost, energy intensity and optional emissions.

Inputs are sent to the server for this calculation without being saved or added to the URL. Saving a scenario stores it only in this browser.

Calculation inputs

Enter decimals with a point or comma, without thousands separators. Blank optional values stay unknown.

Use one currency throughout. “Currency” denotes your chosen currency; no exchange rates or market prices are supplied.

m³/hgreater than: 0 · maximum: 1,000,000
mminimum: 0 · maximum: 30,000
kg/m³greater than: 0 · maximum: 5,000
%greater than: 0 · maximum: 100
hminimum: 0 · maximum: 8,784
currency/kWhminimum: 0 · maximum: 1,000,000
kg CO₂e/kWhminimum: 0 · maximum: 100
Clear inputs

Example inputs are illustrative, not data from a real well.

Formula and assumptions

Assumes steady incompressible flow, a known total dynamic head and overall motor/drive/pump efficiency. Hours describe your chosen period (up to 8,784 h). Pump curves, NPSH and transients are not calculated. Emissions require your own stated factor.

Pₕ = ρ × 9.80665 × (Q / 3600) × H / 1000; Pₑ = Pₕ / (η / 100); E = Pₑ × h; C = E × tariff

Method references

Connect your research